OHAUS FD15 Instruction Manual - 4 Maintenance

Other manuals for FD15: Service Manual, Instruction Manual
Manual is about: FD Series

Summary of FD15

  • Page 1

    Fd series instruction manual serie fd manual de instrucciones série fd guide de l'utilisateur visit www.Balances.Com to see the full line of ohaus balances buy your next ohaus balance online at https://scaleman.Com/.

  • Page 2

    Visit www.Balances.Com to see the full line of ohaus balances buy your next ohaus balance online at https://scaleman.Com/.

  • Page 3

    This product conforms to the emc directive 2004/108/ec and the low voltage directive 2006/95/ec. The complete declaration of conformity is available from ohaus corporation este producto se conforma con el emc 2004/108/ec directivo y la baja tensión 2006/95/ec directivo. El declaración completo de la...

  • Page 4

    Important notice for verified weighing instruments weighing instruments verified at the place of manufacture bear one of the preceding mark on the packing label and the green ‘m’ (metrology) sticker on the descriptive plate. They may be put into service immediately. Weighing instruments to be verifi...

  • Page 5

    Disposal in conformance with the european directive 2002/96 ec on waste electrical and electronic equipment (weee) this device may not be disposed of in domestic waste. This also applies to countries outside the eu, per their specific requirements. Please dispose of this product in accordance with l...

  • Page 6

    Fcc note this equipment has been tested and found to comply with the limits for a class b digital device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and ca...

  • Page 7

    En-1 fd series table of contents 1 introduction ................................................................................................................... En-3 1.1product description ........................................................................................................ .En...

  • Page 8

    Fd series en-2 3.7.2 setup sub-menu ............................................................................................... En-15 3.7.3 readout sub-menu ............................................................................................ En-16 3.7.4 unit sub-menu .......................

  • Page 9: 1 Introduction

    En-3 fd series 1 introduction this manual contains installation, operation and maintenance instructions for the fd series scale. Please read the manual completely before installation and operation. 1.1 product description the fd series is an easy-to-clean and rugged compact scale engineered specific...

  • Page 10: 1.3 Safety Precautions

    Fd series en-4 1.3 safety precautions for safe and dependable operation of this scale, please comply with the following safety precautions: • verify that the input voltage printed on the ac adapter’s data label and the plug type matches the local ac power supply. • make sure that the power cord does...

  • Page 11: 2 Installation

    En-5 fd series pan leveling feet x 4 level indicator load pads x 4 foot switch connector 2 installation 2.1 unpacking unpack and verify that the following components have been included: • fd scale • instruction manual • weighing pan • warranty card • ac adapter • weights and measures sealing kit sav...

  • Page 12: 2.5 Initial Calibration

    Fd series en-6 plug the ac adapter into the receptacle marked “power in” located on the underside of the scale and allow it to charge. While the battery is charging, the segments in the battery symbol will alternately light. When the battery is fully charged, the battery symbol will disappear. 2.4.2...

  • Page 13: 3 Operation

    En-7 fd series 3 operation 3.1 overview of parts and controls identify parts and controls using item numbers from table 1. Figure 3-2. Control panel. Figure 3-1. Parts. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 visit www.Balances.Com to see the full line of ohaus balances buy your next o...

  • Page 14

    Fd series en-8 figure 3-3. Display. Item description 1 control buttons 2 display 3 data label 4 weighing pan 5 adjustable leveling feet 6 connection for ac adapter 7 connection for optional foot switch 8 security cover 9 power and zero button 10 gross/net/tare and unit button 11 target/menu button 1...

  • Page 15: 3.2 Control Functions

    En-9 fd series 3.2 control functions four multi-function buttons are used to operate the scale. 3.3 basic operation 3.3.1 turning on with the scale off, press the on/zero off button. The scale performs a display test, then displays zero. 3.3.2 turning off with the scale on, press and hold the on/zer...

  • Page 16: 3.4 Menu

    Fd series en-10 automatic tare (refer to section 3.7.3) auto-tare is a convenience feature that automatically tares the initial weight (such as an empty container) placed on the empty pan, without having to press the tare button. The tare value is cleared automatically when the weight on the pan is ...

  • Page 17: 3.5 Application Modes

    En-11 fd series 3.4.2 menu navigation use the four buttons marked with yes, no, back and exit to navigate through the menus (refer to section 3.2). • yes - enters the displayed sub-menu or menu item and accepts the displayed setting. • no - skips to the next sub-menu or menu item and changes the dis...

  • Page 18

    Fd series en-12 negative checkweighing in “negative” checkweighing, the part of an item subsequently removed from the pan is checked against the target limits. This method may be preferred in portioning applications. • set both targets as negative values, where the lightest acceptable weight is ente...

  • Page 19: 3.7 Scale Settings

    En-13 fd series 3.7 scale settings enter the menu mode. Proceed to a menu item and use the yes and no buttons to view and select available scale settings. When the desired changes have been made, press exit to return to weighing. Refer to section 3.4 for more information on how to enter and navigate...

  • Page 20

    Fd series en-14 span calibration procedure • when cal is displayed, press yes to enter the calibration sub-menu. • when span is displayed, press yes to begin the span calibration process. • clear the pan if prompted to do so, then press yes..... • the display will show “--c--”, followed by the span ...

  • Page 21

    En-15 fd series 3.7.2 setup sub-menu press yes to enter the setup sub-menu. Reset press yes to enter the reset menu. • no - does not change the setup sub-menu settings. • yes -reset the setup sub-menu to the factory default settings (bold and underlined text herein). Calibration unit press yes to en...

  • Page 22

    Fd series en-16 3.7.3 readout sub-menu press yes yes yes yes yes to enter the readout sub-menu. Reset press yes to enter the reset menu. • no - does not change the readout sub-menu settings. • yes -reset the readout sub-menu to the factory default settings (bold and underlined text herein). Averagin...

  • Page 23

    En-17 fd series k p 3.7.4 unit sub-menu press yes yes yes yes yes to enter the unit sub-menu. Reset press yes to enter the reset menu. • no - does not change the unit sub-menu settings. • yes -reset the unit sub-menu to the factory default settings (bold and underlined text herein). Gram unit press ...

  • Page 24

    Fd series en-18 3.7.5 mode sub-menu press yes yes yes yes yes to enter the mode sub-menu. Reset press yes to enter the reset menu. • no - does not change the mode sub-menu settings. • yes -reset the mode sub-menu to the factory default settings (bold and underlined text herein). Checkweigh mode pres...

  • Page 25

    En-19 fd series 3.7.6 lockout sub-menu press yes yes yes yes yes to enter the lockout sub-menu. Reset press yes to enter the reset sub-menu. • no - does not change the lockout sub-menu settings. • yes -reset the lockout sub-menu to the factory default settings (bold and underlined text herein). Lock...

  • Page 26: 3.9 Sealing The Scale

    Fd series en-20 3.8 legal for trade settings the fd series is designed to comply with oiml, eec, ntep and measurement canada weights and measures regulations. These approvals may be pending; contact ohaus for further details about availability. Note: consult your local weights and measures office fo...

  • Page 27: 4 Maintenance

    En-21 fd series table 4-1. Troubleshooting. 4 maintenance 4.1 calibration verify calibration periodically by placing either a astm class 4 weight or an oiml class f2 weight on the scale and compare the reading to the specifications. Refer to section 3.7.1 for calibration procedure. 4.2 cleaning • di...

  • Page 28: 4.4 Service Information

    Fd series en-22 4.4 service information if the troubleshooting section does not resolve or describe your problem, contact your authorized ohaus service agent. For service assistance in the united states and canada, please call ohaus corporation toll free at (800) 526-0659 from 8 am to 5 pm eastern t...

  • Page 29: 5 Technical Data

    En-23 fd series 5 technical data 5.1 drawings figure 5-1. Scale dimensions. 5.2 specifications the specifications apply under the following ambient conditions: temperature range: -10 to 40 °c atmospheric humidity: maximum relative humidity 80% for temperatures up to 31 °c decreasing linearly to 50% ...

  • Page 30

    Fd series en-24 table 5-1. Specifications. Note: product specifications are subject to change without any obligation on the manufacturer. Maximum displayed resolution 1:6000 1:7500 1:7500 model fd3 fd6 fd15 capacity x readability (max x d non-approved) 3 kg x 0.0005 kg 3000 g x 0.5 g 6 lb x 0.001 lb...

  • Page 31

    En-25 fd series table 5-2. Specifications. Note: product specifications are subject to change without any obligation on the manufacturer. Model fd3h fd6h fd15h capacity x readability (max x d non-approved) 3 kg x 0.0001 kg 3000 g x 0.1 g 6 lb x 0.0002 lb 96 oz x 0.005 oz 96 oz x 1/4 oz 6 lb 0 oz x 0...

  • Page 32: Limited Warranty

    Fd series en-26 limited warranty ohaus products are warranted against defects in materials and workmanship from the date of delivery through the duration of the warranty period. During the warranty period ohaus will repair, or, at its option, replace any component(s) that proves to be defective at n...