OHAUS Ranger R21PE15 Instruction Manual - Ranger™ 2000

Manual is about: Ranger 2000 Series

Summary of Ranger R21PE15

  • Page 1

    Range r™ 2000 series instruction manual.

  • Page 3: Ranger™ 2000

    Ranger™ 2000 series en-1 1. Introduction this manual contains installation, operation and maintenance instructions for the ranger™ 2000 series. Please read the manual completely before using the scale. 1.1 safety precautions please follow these safety precautions: verify that the ac input voltage pr...

  • Page 4: En-2

    En-2 ranger™ 2000 series 2.3 selecting the location use the scale on a firm, steady surface. Avoid locations with excessive air current, vibrations, heat sources or rapid temperature changes. Allow sufficient space around the scale. 2.4 leveling the equipment the ranger series has a level indicator ...

  • Page 5: Ranger™ 2000

    Ranger™ 2000 series en-3 2.5.1 battery power: the scale can be used on ac power immediately. The scale will automatically switch to battery operation if there is a power failure or the power cord is removed. The scale can be operated during charging, and the battery is protected against overcharging...

  • Page 6: En-4

    En-4 ranger™ 2000 series 3. Operation 3.1 controls figure 3-1. Ranger 2000 control panel table 3-1. Button functions button functions on/zero off yes short press 1 (when on): sets display to zero (when off): turns scale on long press 2 (when on): turns the scale off short press (in menu): selects/ac...

  • Page 7: Ranger™ 2000

    Ranger™ 2000 series en-5 table 3-2. Symbols item description item description 1 net symbol 8 dynamic symbol 2 center of zero symbol 9 battery charge symbol 3 negative symbol 10 pound, ounce, pound:ounce symbols 4 stable weight symbol 11 kilogram, gram symbols 5 preset tare, tare symbols 12 pieces sy...

  • Page 8: En-6

    En-6 ranger™ 2000 series the colored led indicators on the left side of the control panel are used in check mode (section 3.6) and will light up according to the following rules: (red) loads > upper limit (green) loads ≥ lower limit and ≤ upper limit (yellow) loads figure 3-4. Below view of ranger 2...

  • Page 9: Ranger™ 2000

    Ranger™ 2000 series en-7 3.3 weigh mode this mode is the factory default setting. 1. If needed, press and hold mode until [wweigh] (weigh) is displayed. 2. If required, place an empty container on the pan and press tare. 3. Add sample to the pan or container. The display shows the weight of the samp...

  • Page 10: En-8

    En-8 ranger™ 2000 series 8. To clear the stored apw press and hold mode until [count] is displayed. Press yes when [clr.Pww] is displayed. Note: press function to view the current apw. 3.6 check mode use this mode to compare the weight, percent or count of items to a target weight range. The scale s...

  • Page 11: Ranger™ 2000

    Ranger™ 2000 series en-9 5. The scale will display [cl.Limm] (clear check limits). 6. Press no to use the stored check limits and proceed to step 9. 7. Press yes to establish new check limits. The scale will then display [set. Lo]. Press yes to view the “low” limit value. Press yes to accept or no t...

  • Page 12: En-10

    En-10 ranger™ 2000 series 10. Place sample material on the pan or in the container. If the sample weight is under the target quantity range, the yellow led will light. If the sample is within the target quantity range, the green led will light. If the sample is over the target quantity range, the re...

  • Page 13: Ranger™ 2000

    Ranger™ 2000 series en-11 4. Manually reset the countdown timer by pressing the function key. [ready] (ready) will then be displayed. Note: if set0 has been selected, the countdown timer is not displayed. The first weight larger than 5d will be displayed and held. Semi-automatic operation (dynamic i...

  • Page 14: En-12

    En-12 ranger™ 2000 series 3.8 accumulation and statistics the accumulation feature enables manual or automatic totalizing of displayed values. Statistical data is stored in memory for review and printing. Accumulation works together with each application mode except dynamic. 3.8.1 accumulating displ...

  • Page 15: Ranger™ 2000

    Ranger™ 2000 series en-13 accumulation example: in weighing mode; sub menu accumm setting, select mmanu: if required, place an empty container on the pan and press tare. Step i: put the weight (0.04 kg) on the pan and press m+ key. The Σ icon indicator will keep flashing until the weight is removed ...

  • Page 16: En-14

    En-14 ranger™ 2000 series 3.9 additional features to use the weigh below hook feature, remove power from the scale and remove the protective cover for the weigh below opening. Install the hook (accessory) into the access hole at the bottom of the scale as shown. Do not over tighten, tighten finger t...

  • Page 17: Ranger™ 2000

    Ranger™ 2000 series en-15 4. Menu settings the user menu allows the customizing of scale settings. Note: additional sub-menus may be available if interface options are installed. See interface user manual for the additional setting information. 4.1 menu structure user menu: menu: c.A.L s.E.T.U.P r.E...

  • Page 18: En-16

    En-16 ranger™ 2000 series 4.2 menu navigation summary of button navigation functions in menu mode: -- yes allows entry into the displayed menu. - accepts the displayed setting and advances to the next item. -- no skips by the displayed menu. - rejects the displayed setting or menu item and advances ...

  • Page 19: Ranger™ 2000

    Ranger™ 2000 series en-17 4.3 calibration menu enter this menu to perform calibrations. Initial calibration when the scale is operated for the first time, a span calibration is recommended to ensure accurate weighing results. Before performing the calibration, be sure to have the appropriate calibra...

  • Page 20: En-18

    En-18 ranger™ 2000 series 4.4 setup menu enter this menu to set scale parameters. Reset [reset] reset the setup menu to factory defaults. No = not reset yes = reset power on unit [pwwr.Un] set the unit of measure displayed at startup. Auto = last unit in use when turned off kg = kilograms g = grams ...

  • Page 21: Ranger™ 2000

    Ranger™ 2000 series en-19 beeper key [bp.Key] set whether the beeper sounds when a button is pressed. Off = no sound on = sound accumulation [accumm] set the accumulation functionality. Off = accumulation disabled auto = automatic accumulation man = manual accumulation end setup [end] advance to the...

  • Page 22: En-20

    En-20 ranger™ 2000 series auto-zero tracking [azt] set the automatic zero tracking functionality. Off = disabled 0.5d = the display will maintain zero until a change of 0.5 divisions per second has been exceeded. 1d = the display will maintain zero until a change of 1 divisions per second has been e...

  • Page 23: Ranger™ 2000

    Ranger™ 2000 series en-21 4.6 mode menu this menu activates modes so they will be available for use with the mode button. Reset [reset] reset the mode menu to factory defaults. No = not reset yes = reset weigh [wweigh] set the status. Off = disabled on = enabled percent [percnt] set the status. Off ...

  • Page 24: En-22

    En-22 ranger™ 2000 series 4.7 unit menu this menu activates units so they will be accessible with the units button. The units in the menu m ust be turned “on” to be active. Note: available units vary by model and local regulations..

  • Page 25: Ranger™ 2000

    Ranger™ 2000 series en-23 4.8 print menu enter this menu to set printing parameters. Reset [reset] reset the print menu to factory defaults. No = no reset yes = reset stable only [stable] set the printing criteria. Off = values are printed immediately on = values are only printed when the stability ...

  • Page 26: En-24

    En-24 ranger™ 2000 series content [contnt] define the content of the printed data. Result set the status. Off = disabled on = the displayed reading is printed gross set the status. Off = disabled on = the gross weight is printed net set the status. Off = disabled on = the net weight is printed tare ...

  • Page 27: Ranger™ 2000

    Ranger™ 2000 series en-25 accu set the status. Off = disabled result = the accumulation result is printed all = all the accumulation data is printed layout [layout] set the format of the data output to a printer or computer. Format set the printing format. Multi = a multi-line (single column style) ...

  • Page 28: En-26

    En-26 ranger™ 2000 series 4.9 com menu enter this menu to define communication parameters. Reset [reset] reset the com menu to factory defaults. No = no reset yes = reset baud rate [baud] set the baud rate. 300 = 300 bps 600 = 600 bps 1200 = 1200 bps 2400 = 2400 bps 4800 = 4800 bps 9600 = 9600 bps 1...

  • Page 29: Ranger™ 2000

    Ranger™ 2000 series en-27 alternate command [alt.Cmm] define command character for the print, tare and zero commands print set the alternate command character for print. A to z. Tare set the alternate command character for tare. A to z. Zero set the alternate command character for zero. A to z. End ...

  • Page 30: En-28

    En-28 ranger™ 2000 series 4.10 lock menu the lock menu is a software controlled option which can lock menu settings to prevent tampering. Reset [reset] reset the lock menu to factory defaults. No = no reset yes = reset lock cal [l.Cal] set the status. Off = calibration menu is not locked. On = calib...

  • Page 31: Ranger™ 2000

    Ranger™ 2000 series en-29 lock com [l.Comm] set the status. Off = com menu is not locked. On = com menu is locked. End lock [end] advance to the next menu or return to the top of the current menu. 4.11 end menu press ‘yes’ to exit the menu and return to the current application mode. Press ‘no’ to ad...

  • Page 32: En-30

    En-30 ranger™ 2000 series table 4-2. Geo codes 0 325 650 975 1300 1625 1950 2275 2600 2925 3250 325 650 975 1300 1625 1950 2275 2600 2925 3250 3575 0 1060 2130 3200 4260 5330 6400 7460 8530 9600 10660 1060 2130 3200 4260 5330 6400 7460 8530 9600 10660 11730 0°00' 5°46' 5 4 4 3 3 2 2 1 1 0 0 5°46' 9°...

  • Page 33: Ranger™ 2000

    Ranger™ 2000 series en-31 5. Legal for trade when the scale is used in trade or a legally controlled application it must be set up, verified and sealed in accordance with local weights and measures regulations. It is the responsibility of the purchaser to ensure that all pertinent legal requirements...

  • Page 34: En-32

    En-32 ranger™ 2000 series 6. Maintenance 6.1 cleaning the housing may be cleaned with a cloth dampened with a mild detergent if necessary. Do not use solvents, chemicals, alcohol, ammonia or abrasives to clean the housing or control panel. 6.2 troubleshooting the following table lists common problem...

  • Page 35: Ranger™ 2000

    Ranger™ 2000 series en-33 6.3 service information if the troubleshooting section does not resolve or describe your problem, contact your authorized ohaus service agent. For service assistance or technical support in the united states call toll-free 1-800-526-0659 between 8:00 am and 5:00 pm est. An ...

  • Page 36: En-34

    En-34 ranger™ 2000 series 7. Technical data the technical data is valid under the following ambient conditions: operating temperature: -10°c to 40°c relative humidity: 20% to 85% relative humidity, non-condensing height above sea level: up to 2000 m power: ac power 200-240v 50/60 hz, internal rechar...

  • Page 37: Ranger™ 2000

    Ranger™ 2000 series en-35 7.2 drawings figure 7-1. Dimensions 311 mm / 12.2 in 327 mm / 12.9 in 116 mm / 4.6 in 117 mm / 4.6 in.

  • Page 38: En-36

    En-36 ranger™ 2000 series 7.3 communication the scale is equipped with an rs232 interface located under the options cover. Connecting the scale to a computer enables you to operate the scale from the computer, as well as receive data such as displayed weight. 7.3.1 interface commands communicate to ...

  • Page 39: Ranger™ 2000

    Ranger™ 2000 series en-37 7.4 printouts the following sample print outs are generated by the print button, “p” command or alternate print command. The content of the printout is defined in the print content menu item. Weigh mode printout description comment 12.34 kg result line if printx  content ...

  • Page 40: En-38

    En-38 ranger™ 2000 series percent mode printout description comment 102.83 % result line if printx  content  result is on 12.34 kg g gross value line if printx  content  gross is on and a tare value is entered 11.11 kg n net value line if printx  content  net is on and a tare value is entered ...

  • Page 41: Ranger™ 2000

    Ranger™ 2000 series en-39 dynamic mode printout description comment 12.34 kg result line if printx  content  result is on 12.34 kg g gross value line if printx  content  gross is on and a tare value is entered 11.11 kg n net value line if printx  content  net is on and a tare value is entered ...

  • Page 42: En-40

    En-40 ranger™ 2000 series limited warranty ohaus products are warranted against defects in materials and workmanship from the date of delivery through the duration of the warranty period. During the warranty period ohaus will repair, or, at its option, replace any component(s) that proves to be defe...

  • Page 44

    Ohaus corporation 7 campus drive suite 310 parsippany, nj 07054 usa tel: +1 973 377 9000 fax: +1 973 944 7177 with offices worldwide / con oficinas alrededor del mundo / avec des bureaux dans le monde entier / weltweite geshäftsstellen / con uffici in tutto il mondo. Www.Ohaus.Com *30037458* p/n 300...