OHAUS RC31P15 Instruction Manual

Manual is about: OHAUS Ranger Count 3000 Series Scales

Summary of RC31P15

  • Page 1

    Range r™ count 3000 series instruction manual.

  • Page 3: 1. Introduction

    Ranger™ count 3000 series en-1 1. Introduction this manual contains installation, operation and maintenance instructions for the ranger™ count 3000 series. Please read the manual completely before using the scale. 1.1 definition of signal warnings and symbols safety notes are marked with signal word...

  • Page 4: En-2

    En-2 ranger™ count 3000 series 2.2 installing components install the sub-platform & metal pan as shown below. Press to lock the sub-platform into place. The scale can be operated without the pan, if desired. Figure 2-1. Installing sub-platform and metal pan 2.3 selecting the location use the scale o...

  • Page 5

    Ranger™ count 3000 series en-3 2.5 connecting power ac power is used to power the scale when battery power is not needed. First, connect the ac power cord (supplied) to the power input jack then connect the ac plug to an electrical outlet. 2.5.1 battery power: the scale can be used on ac power immed...

  • Page 6: En-4

    En-4 ranger™ count 3000 series 3. Operation 3.1 displays figure 3-1. Ranger count 3000 control panel with lcd displays table 3-1. Control functions button primary function (short press 1 ) on/zero turn scale on. Zero the display. Print send the displayed value to the com port. Target initiate the fu...

  • Page 7

    Ranger™ count 3000 series en-5 table 3-1. Cont. Button primary function (short press) 0-9 enter numeric values on the display. Enter decimal point (.) on the display. C clear the last character from the display. Tare perform a tare operation. Sample display/ start new apw secondary function (long pr...

  • Page 8: En-6

    En-6 ranger™ count 3000 series the colored led indicators on the left side of the control panel are used in checkweigh mode (section 3.5) and will light up according to the following rules: (red) loads > upper limit (green) loads ≥ lower limit and ≤ upper limit (yellow) loads figure 3-3. Below view ...

  • Page 9

    Ranger™ count 3000 series en-7 3.2 turning scale on/off to turn the scale on, press and hold the on/zero off button for 1 second. The scale performs a display test, momentarily displays the software version, and then enters the active weighing mode. To turn the scale off, press and hold the on/zero ...

  • Page 10: En-8

    En-8 ranger™ count 3000 series entering a known apw: 1. Press the apw key, [------] will be displayed in the piece window 2. Input the apw value. 3. Press the apw key, the new apw value will be displayed in piece weight window. 3.3.3 simple counting 1. After a valid apw is established, if required p...

  • Page 11

    Ranger™ count 3000 series en-9 5. If required, place an empty container on the pan and press tare. 6. Place sample material on the pan or in the container. If the sample weight is under the target weight range, the yellow led will light. If the sample is within the target weight range, the green led...

  • Page 12: En-10

    En-10 ranger™ count 3000 series 3.7 library when an item is processed on a regular basis, the item’s data (item or sku numbers, tare, check limits and accumulated values) may be stored in memory for future use. This memory is referred to as the scale’s library. Storing a record: 1. With the data est...

  • Page 13: 4. Menu Settings

    Ranger™ count 3000 series en-11 4. Menu settings the user menu allows the customizing of scale settings. Note: additional sub-menus may be available if interface options are installed. See interface user manual for the additional setting information. 4.1 menu navigation user menu: menu: c.A.L s.E.T....

  • Page 14: En-12

    En-12 ranger™ count 3000 series summary of button navigation functions in menu mode: -- yes allows entry into the displayed menu. - accepts the displayed setting and advances to the next item. -- no skips by the displayed menu. - rejects the displayed setting or menu item and advances to the next av...

  • Page 15

    Ranger™ count 3000 series en-13 4.2 cal menu enter this menu to perform calibrations. Initial calibration when the scale is operated for the first time, a span calibration is recommended to ensure accurate weighing results. Before performing the calibration, be sure to have the appropriate calibrati...

  • Page 16: En-14

    En-14 ranger™ count 3000 series zero2 [zero] initiates a 2 nd scale zero calibration. Span1 [span] initiates a span calibration procedure (zero and span). A span calibration is important when initially setting up the scale. Span2 [span2] initiates a 2 nd scale span calibration procedure. Lin1 [lin] ...

  • Page 17

    Ranger™ count 3000 series en-15 4.3 setup menu enter this menu to set scale parameters. Default settings are in bold. Reset [reset] reset the setup menu to factory defaults. No = not reset yes = reset dual scale [d.Scale] set the status of the second scale input (scale 2). Off = disabled on = enable...

  • Page 18: En-16

    En-16 ranger™ count 3000 series auto tare [a.Tare] set the automatic tare functionality. Off = automatic tare is disabled on = the first stable gross weight is tared on-acc = stable gross loads within the accept limits are tared (in check weighing mode) beeper opt [bp.Opt] set whether or not the bee...

  • Page 19

    R anger™ count 3000 series en-17 4.4 readout menu enter this menu to set user preferences. Default settings are in bold. Reset [reset] reset the read menu to factory defaults. No = not reset yes = reset stable range [stable] set the amount the reading can vary while the stability symbol remains on. ...

  • Page 20: En-18

    En-18 ranger™ count 3000 series 4.5 unit menu this sub-menu activates units so they will be accessible with the units button. The units in the menu must be turned “on” to be active. Note: available units vary by model and local regulations..

  • Page 21: Ranger™ Count 3000

    Ranger™ count 3000 series en-19 4.6 print1 menu enter this menu to set printing parameters. Default settings are in bold. Note: the print2 menu is only displayed if a second interface is installed. Reset [reset] reset the print menu to factory defaults. No = no reset yes = reset stable only [stable]...

  • Page 22: En-20

    En-20 ranger™ count 3000 series result set the status. Off = disabled on = the displayed reading is printed gross set the status. Off = disabled on = the gross weight is printed net set the status. Off = disabled on = the net weight is printed tare set the status. Off = disabled on = the tare weight...

  • Page 23: Ranger™ Count 3000

    Ranger™ count 3000 series en-21 accu set the status. Off = disabled result = the accumulation result is printed all = all the accumulation data is printed note: see section 7.4 for sample print out. Layout [layout] set the format of the data output to a printer or computer. Format set the printing f...

  • Page 24: En-22

    En-22 ranger™ count 3000 series 4.7 com1 menu enter this menu to define communication parameters. Default settings are in bold. Note: the com2 menu is only displayed if a second interface is installed. Reset [reset] reset the com menu to factory defaults. No = no reset yes = reset baud rate [baud] s...

  • Page 25: Ranger™ Count 3000

    Ranger™ count 3000 series en-23 alternate command [alt.Cmm] define command character for the print, tare and zero commands print set the alternate command character for print a to z. Tare set the alternate command character for tare a to z. Zero set the alternate command character for zero. A to z. ...

  • Page 26: En-24

    En-24 ranger™ count 3000 series lock print [l.Print] set the status. Off = print menu is not locked on = print menu is locked lock com [l.Comm] set the status. Off = com menu is not locked on = com menu is locked end lock [end] advance to the next menu or return to the top of the current menu. 4.9 e...

  • Page 27: Ranger™ Count 3000

    Ranger™ count 3000 series en-25 table 4-2. Geo codes 0 325 650 975 1300 1625 1950 2275 2600 2925 3250 325 650 975 1300 1625 1950 2275 2600 2925 3250 3575 0 1060 2130 3200 4260 5330 6400 7460 8530 9600 10660 1060 2130 3200 4260 5330 6400 7460 8530 9600 10660 11730 0°00' 5°46' 5 4 4 3 3 2 2 1 1 0 0 5°...

  • Page 28: En-26

    En-26 ranger™ count 3000 series 5. Legal for trade when the scale is used in trade or a legally controlled application it must be set up, verified and sealed in accordance with local weights and measures regulations. It is the responsibility of the purchaser to ensure that all pertinent legal requir...

  • Page 29: Ranger™ Count 3000

    Ranger™ count 3000 series en-27 figure 5-2. Sealing 5.3.2 audit trail seal (usa and canada only) for jurisdictions that use the audit trail sealing method, the local weights and measures official or authorized service agent must record the current configuration and calibration event counter values a...

  • Page 30: En-28

    En-28 ranger™ count 3000 series 6. Maintenance 6.1 cleaning the housing may be cleaned with a cloth dampened with a mild detergent if necessary. Do not use solvents, chemicals, alcohol, ammonia or abrasives to clean the housing or control panel. 6.2 troubleshooting table 6-1 lists common problems an...

  • Page 31

    Ranger™ count 3000 series en-29 6.3 service information if the troubleshooting section does not resolve or describe your problem, contact your authorized ohaus service agent. For service assistance or technical support in the united states call toll-free 1-800-526-0659 between 8:00 am and 5:00 pm es...

  • Page 32: En-30

    En-30 ranger™ count 3000 series 7. Technical data the technical data is valid under the following ambient conditions: indoor use only operating temperature: -10°c to 40°c relative humidity: 20% to 85% relative humidity, non-condensing height above sea level: up to 2000 m power: ac power 100-240v 50/...

  • Page 33

    Ranger™ count 3000 series en-31 7.2 drawings figure 7-1. Dimensions 311 mm / 12.2 in 327 mm / 12.9 in 117 mm / 4.6 in.

  • Page 34: En-32

    En-32 ranger™ count 3000 series 7.3 communication the scale is equipped with an rs232 interface (com1) located under the options cover. Connecting the scale to a computer enables you to operate the scale from the computer, as well as receive data such as displayed weight. 7.3.1 interface commands co...

  • Page 35

    Ranger™ count 3000 series en-33 7.4 printouts the following sample print outs are generated by the print button, “p” command or alternate print command. The content of the printout is defined in the print content menu item. A maximum of 24 characters can be printed on each line. Description comment ...

  • Page 36: En-34

    En-34 ranger™ count 3000 series 7.6 compliance compliance to the following standards is indicated by the corresponding mark on the product. Mark standard this product conforms to the emc directive 2004/108/ec, the low voltage directive 2006/95/ec and the non-automatic weighing instrument directive 2...

  • Page 37

    Ranger™ count 3000 series en-35 disposal in conformance with the european directive 2002/96/ec on waste electrical and electronic equipment (weee) this device may not be disposed of in domestic waste. This also applies to countries outside the eu, per their specific requirements. The batteries direc...

  • Page 38: En-36

    En-36 ranger™ count 3000 series limited warranty ohaus products are warranted against defects in materials and workmanship from the date of delivery through the duration of the warranty period. During the warranty period ohaus will repair, or, at its option, replace any component(s) that proves to b...

  • Page 40

    Ohaus corporation 7 campus drive suite 310 parsippany, nj 07054 usa tel: +1 973 377 9000 fax: +1 973 944 7177 with offices worldwide / con oficinas alrededor del mundo / avec des bureaux dans le monde entier / weltweite geshäftsstellen / con uffici in tutto il mondo. Www.Ohaus.Com *30037454* p/n 300...