  • Page 1

    User’s guide version 1.2 oki electric industry co., ltd. Oki voice over ip telephony adapter.

  • Page 3

    Safety warning! This document contains information regarding the safe use of the oki voip-ta unit. Carefully observe and comply with all safety precautions..

  • Page 4

    Ii © 1999-2000, oki electric industry co., ltd. All rights reserved. The voip-ta internet telephony adapter and the maintenance console software are products of oki electric industry co. Ltd. The right to reproduce this manual and/or the maintenance console software is restricted by the copyright ac...

  • Page 5: Contents

    Iii contents contents important safety instructions iv introduction vi i outline 1 the voip-ta 1 features 1 front panel 2 leds 2 back panel 3 connectors 3 ii installation 5 connections 5 cautions 7 iii placing calls 8 via an ip network 8 general operation 8 services 9 third party incoming call durin...

  • Page 6

    Iv important safety instructions important safety instructions when handling or using the voip-ta unit, the following safety precautions should be observed to prevent injury and/or damage to the unit. Use of this equipment in a manner other than that specified in this and other voip-ta documents wil...

  • Page 7

    V important safety instructions • do not use ac adapters other than those specified or supplied. • if liquid enters the unit, immediately disconnect the power plug (by grasping the power plug, not the cord) from the power outlet and contact an authorized sales agent or service provider. Continued us...

  • Page 8: Introduction

    Vi introduction introduction welcome to the world of oki internet telephony… the oki voice over ip (internet protocol) telephony adapter, voip-ta, is a self-contained h.323 version 2 compliant communications device that allows organizations to route both voice and facsimile communications over any t...

  • Page 9: Outline

    1 outline i i outline the voip-ta the voip-ta is a one-channel internet telephony adapter that provides internet telephony services conforming to industry standard h.323 version 2 specifications. It can be connected to a conventional analogue telephone or g3 facsimile machine. Once installed, voip-t...

  • Page 10: Front Panel

    2 outline power indicates power on when lit. Green lamp. Alarm indicates alarmed condition detected in unit when lit. Red lamp. (see table 1 p. 4) line indicates pstn line is used during operation when lit. Green lamp. Lan indicates lan link is established and operating normally when lit . When blin...

  • Page 11: Back Panel

    3 outline back panel connectors tel connects a conventional analogue telephone or g3 facsimile machine. Dial signal: dtmf signaling only. Line connects to an analogue public telephone line. Pc* connects to a pc via a straight cable (category 3 or higher). Not for maintenance console software. Use ca...

  • Page 12

    4 outline mode alarm-led line-led status initialization blinks off with gatekeeper: (1 sec. The system will wait for intervals) lan link to be established while gatekeeper registers the voip-ta. Without gatekeeper: the system will wait for a lan link to be established. Operation off off standby off ...

  • Page 13: Installation

    5 ii ii installation ii ii installation place the main unit in a vertical position as placing it horizontally could shorten the life of the unit. Connections the following illustration shows where equipment should be connected to the ports at the rear of the voip-ta unit. Analogue telephone or g3 fa...

  • Page 14: Personal Computer

    6 personal computer (pc) connect a pc connector to the pc port at the back of the voip-ta unit using an unshielded twisted pair (utp) straight cable (categories 3 to 5). If both a pc and lan are to use 100base-tx communications, use category 5 [max. 100m]. It is recommended that only one pc is conne...

  • Page 15: Cautions

    7 installation cautions during installation • all cables used to connect the equipment must be accessories of the equipment or suitable to fit the equipment. • make sure the ac power plug is disconnected from the power outlet when connecting the fg cable to the unit. • when an exchange machine, such...

  • Page 16: III

    8 iii iii placing calls placing calls via an ip network placing and receiving calls with the voip-ta unit are usually quite simple and performed in the same way as conventional telephone networks. In some cases however, the phone numbers to be used, may differ slightly from the ones you used previou...

  • Page 17: Services

    9 placing calls services third party incoming call during another call you can respond to a third party’s incoming call while you are on another call. • a second party telephone call. • if a third party calls, a notification tone is sent to your telephone. • you may speak to a third party by hooking...

  • Page 18

    10 placing calls end-to-end service using dtmf signaling dtmf signaling can be used via the ip network for answering machines, etc. This service is unavailable when the facsimile transmission, via the voip line, is set in the data setup. For details of the data setup, please contact your network man...

  • Page 19

    11 placing calls • put the other party on hold by hooking, and dial a transfer destination number. • you may then speak to the party at the transfer destination. • when you hang up the handset again the call will be automatically transferred to the destination..

  • Page 20: Absent Service

    12 absent service if the absent service is registered, an incoming call is transferred to a registered destination. The transferred call will not be transferred any further. This service is inapplicable when a pstn is set in the data setup. For details of data setup, please contact your network mana...

  • Page 21: Details of Services

    13 placing calls details of services there are two ways to use the voip-ta unit; using both a pstn line and the ip network or using only the ip network. These services are determined by the data setup. Using both a pstn line and the ip network line selection the selection of a pstn line or ip networ...

  • Page 22

    14 • response to an incoming call from the ip network during a telephone call using a pstn line. • incoming operation from the ip network during a telephone call using the ip network. Placing calls.

  • Page 23

    15 placing calls for pstn line not receiving services using hookflash (hooking). • response to an incoming call from a pstn line during a telephone call using the ip network. • response to an incoming call from the ip network during a telephone call using a pstn line..

  • Page 24: Using The Ip Network Only

    16 • incoming operation from the ip network during a telephone call using the ip network. Using the ip network only incoming call during an existing telephone call. Placing calls.

  • Page 25: Troubleshooting

    17 troubleshooting iv iv symptom items to check unit does not • is the power turned on? Check the power operate. Lamp to see if it is lit. • is the power plug inserted into the port correctly? • is the ac power adapter connected to the power outlet correctly? The alarm lamp • is the lan port link es...

  • Page 26: Specifications

    Tel port interface conventional analogue telephone line selection signal dtmf signal fax transmission 14,400 bps 12,000 bps 9,600 bps speed 7,200 bps 4,800 bps 2,400 bps number of only one connectable ports lan port interface 10base-t/100base-tx pc port interface 10base-t/100base-tx line port interf...

  • Page 27

    19 important equipment information important equipment information the following information relates to the voip-ta compliance with radio interference requirements of various countries in which this equipment is sold. Eu model voip-ta conforms to the following directives: • low voltage directive: 73...

  • Page 28: Warranty and Service

    20 warranty and service warranty and service our authorized sales agents or service office will respond to your inquiries and services in a prompt and courteous manner. Warranty period in the event of a problem occurring during the warranty period, all necessary repairs and replacements will be done...

  • Page 29: Oki Service Offices

    21 oki service offices oki service offices your local dealer oki electric industry co., ltd. Head office 10-3 shibaura 4-chome, minato-ku, tokyo 108-8551 japan tel: +81-3-5445-6346/6353 fax: +81-3-5445-6363/6364 url: http://www.Oki.Co.Jp london office central house, balfour road hounslow, middlesex ...

  • Page 30: 3Pp3507-4104P002