P3 International P4320 Operating Manual

Other manuals for P4320: Specification Sheet
Manual is about: Relocatable Power Tap / Transient Voltage Surge Suppressor

Summary of P4320

  • Page 1

    P4320 kill a watt tm ps operating manual thank you for purchasing the p4320 kill a watt™ ps relocatable power tap / transient voltage surge suppressor. This operating manual will provide an overview of the product, safety instructions, a quick guide to operation, and complete instructions for correc...

  • Page 2

    Safety instructions caution Å risk of electric shock do not open ã the lightning flash with arrowhead, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a r...

  • Page 3

    Power-cord protection – power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at plugs, convenience receptacles, and the point where they exit from the product. Lightning – for added prote...

  • Page 4

    Product functions: 1. Power strip: 8 outlets, spike-free switch. 2. Multi-meters: voltage, current, active power, power factor, kwh, leakage current, elapsed time. 3. Protection: abnormal voltage, over current, over load, surge. 4. Programmable breaker current: user adjustable 2, 5, 10, or 15a break...

  • Page 5

    Feature locations display panel quick start guide: use these quick start instructions to get up and running in just a few minutes. Be sure to review all the operating instructions later to ensure full enjoyment of the product. 1. Connect the kill a watt™ ps unit to the outlet and the appliance to th...

  • Page 6

    Installation: 1. Remove the protective film (if any) covering the lcd meter display by pulling the tab marked “remove before use”. 2. Turn off all appliances before connection to the unit and remove their power cords from the outlet. Connect the kill a watt™ ps unit to the outlet and the appliances ...

  • Page 7

    Appliance power consumption (in watts) with the currently measured power factor (in %), the maximum measured watts/pf (indicated by the max icon) and the minimum measured watts/pf (indicated by the min icon). The display will return to the currently measured values after a few seconds. Pressing and ...

  • Page 8

    3. Over current mode: when the current load presented by the connected appliances exceeds the setting on the max. Amps switch, the unit will switch to over current mode. The power will be switched off to the 8 outlets. The red led in the off switch will flash. The lcd will display the protected curr...

  • Page 9

    Troubleshooting: item symptoms action description 1 lcd display is flashing press any key 1. This is normal operation after you plug the unit into a wall outlet. 2. Ac power to the unit has been interrupted. 2 over current icon on lcd is flashing and audible alarm is sounded, output is off and the r...

  • Page 10

    Specifications: accuracy response time item range typ. Max. Action recovery rms voltage 120vrms 0.4% 2% 1sec rms current 0.0~15.0arms 0.6% 2% 1sec active power 0~1800 watt 1% 4% 1sec kwh 1 0.0~9999 kwh 1% 4% 1sec power factor 0~100% pf=w/vrms*arms 1sec leakage current 0~30ma ±1ma 1sec 00day/00hour~9...