PACH & COMPANY Aegis 7000 Plus Installation And Programming Manual

Summary of Aegis 7000 Plus

  • Page 1

    Installation and programming manual rev. 03-04-2011.

  • Page 2: Table Of Contents

    Aegis 7000p page 2 table of contents chapter 1 getting started -------------------------------------------------------------- 4 chapter 2 installation wiring diagram ---------------------------------------- 11 chapter 3 programming ------------------------------------------------------------------ 1...

  • Page 3

    Aegis 7000p page 3 limitations of liability this manual is subject to change without notice. Pach and company is not liable for any errors that might occur from use of this document, nor is any commitment to update the information herein implied. Pach and company does not assume any liability for an...

  • Page 4: Chapter  1

    Aegis 7000p page 4 chapter 1 getting started introduction pach & company thanks and congratulates you on the purchase of your aegis 7000p series telephone entry access control systems. The manual is designed to guide you through the proper programming and use of the aegis 7000p series. It is importa...

  • Page 5

    Aegis 7000p page 5 technical specifications o power input: 12 vac 40 va (supplied) or 12 vdc 40va ul listed transformer o current consumption: 500ma idle, 700ma operation o emergency battery: 12vdc, 4ahr rechargeable (not supplied) o telephone line: standard voice grade rj11 jack. O night light: 14v...

  • Page 6

    Aegis 7000p page 6 limited warranty pach and company new products are warranted to be free of defects in material or workmanship for a period of 24 month from the date of purchase. This warranty extends only to wholesale customers who buy direct from pach and company or through pach and company’s no...

  • Page 7

    Aegis 7000p page 7 there are no obligations and/or liabilities on the part of pach and company for consequential damages arising out of or in connection with use or performance of pach and company products or other indirect damages with respect to loss of property, revenue, or profit, or cost of rem...

  • Page 8

    Aegis 7000p page 8 o the products must be properly installed as specified; and maintained or used as intended cause of product failure is not due to vandalism or malicious mischief, improper installation, abnormal physical or o electrical stress, lightning, power surges, misuse, negligence, accident...

  • Page 9

    Aegis 7000p page 9 o pach and company reserves the right to replace a warranted product with a like product of equal value in the event original system cannot be repaired. O distributors and/or dealer-installer must first obtain a return merchandise authorization (rma) number from pach and company t...

  • Page 10

    Aegis 7000p page 10 insurance fees, for products shipped to pach and company repair center. O pach and company warranty does not guarantee any product, new or repaired, to be free of operation error or service interruption in any way during the course of daily product operation. O pach and company i...

  • Page 11: Chapter  2

    Aegis 7000p page 11 chapter 2 installation wiring diagram checking your installation figure 2.1.

  • Page 12

    Aegis 7000p page 12 1. Turn the “power” on, the display will go into cycle mode as show 2. Check for the tone on the keypad buttons 0-9, # and * 3. Clear the memory. 4. Adjust the speaker volume, press # wait for dial tone, clockwise-decrease, counter clockwise-increase refer to figure 2.1 5. Adjust...

  • Page 13: Chapter  3

    Aegis 7000p page 13 chapter 3 programmming i. Two ways to log-on to programming mode: first using system’s keypad 1. Press 0 and # simultaneously then release, see below press 0# simultaneously, lcd screen will stop scrolling if the lcd is still scrolling repeat the process then 4-digit master code ...

  • Page 14

    Aegis 7000p page 14 ii. Keypad function and layout iii. Programming function codes function code programming 00 master code (0000 is default) change the master code for your security must be in programming mode, see two ways to log-on to programming mode: on page 13 1. Enter function code 00 then pr...

  • Page 15

    Aegis 7000p page 15 3. Enter the person name up to 16-characters. Press # after entering each letter, see (keypad function and layout page 14). Press ## after entering last letter. The screen will show 4. Enter telephone number up to 11 digit, then press #, 5. Enter 4-digit access code then press #....

  • Page 16

    Aegis 7000p page 16 5. Enter 4-digit access code then press #. Repeat step 1 to edit another tenant directory. 03 deleting a directory must be in programming mode, see two ways to log-on to programming mode: on page 13 1. Enter function code 03 then press # 2. Enter directory number to be deleted (i...

  • Page 17

    Aegis 7000p page 17 press # 07 single or multi system 1= single 0= multi default is single must be in programming mode, see two ways to log-on to programming mode: on page 13 1. Enter function code 07 then press # 2. Select 1 or 0 then press # 08 system id not applicable not applicable 10 welcome me...

  • Page 18

    Aegis 7000p page 18 2. Select 0=unmask or 1=mask then press # 46 firmware version must be in programming mode, see two ways to log-on to programming mode: on page 13 1. Enter function code 46 then press # v:7150 is model number 7150p 01/28/11 is firmware release date 50 erase memory to factory defau...

  • Page 19

    Aegis 7000p page 19 2. Press 010-180 then press # 71 door open time 04-99 seconds default is 12 seconds must be in programming mode, see two ways to log-on to programming mode: on page 13 1. Enter function code 71 then press # 2. Press 04-99 then press # 72 lock out count 1-9 times default is 3 time...

  • Page 20

    Aegis 7000p page 20 2. Press 1= enable or 0= disable then press # 77 pbx 0= disable 1= enable default is disable must be in programming mode, see two ways to log-on to programming mode: on page 13 1. Enter function code 77 then press # 2. Press 1= enable or 0= disable then press #, if 1 is selected,...

  • Page 21: Chapter  4

    Aegis 7000p page 21 chapter 4 system’s operation a. How to view tenant’s directory 1. Press (scroll a-z) or 2. Press (scroll z-a) b. How to initiate a call from the system two ways to initiate a call 1. By scrolling (see a, press 3 or 6 to scroll) then press # to call 2. By directory, press # (wait ...

  • Page 22

    Aegis 7000p page 22 g. How to use the 4-digit access code to open the door 1. Press , the welcome screen will stop scrolling otherwise repeat this step. 2. Press 4-digit valid access code. H. How to increase or decrease the display’s intensity 1. Locate the display intensity adjustment see figure 2....

  • Page 23: Chapter  5

    Aegis 7000p page 23 chapter 5 trouble shooting guide audio problems no audio on key(s) press 1. Turn the system’s power off and on 2. Check the speaker and microphone connection, check for broken wires. 3. Disconnect the microphone and speaker connector then check the speaker’s impedance, must read ...

  • Page 24

    Aegis 7000p page 24 no dial tone 1. Turn the system’s power off and on 2. Check the phone line for dial tone. Must check at the end of the phone cord. 3. Disconnect the microphone and speaker connector then check the speaker’s impedance, must read between 18-24 ohms 4. Check the telephone line volta...

  • Page 25

    Aegis 7000p page 25 this equipment complies with part 68 of the fcc rules. Located on the back of your aegis system is a label that contains, among other information, the fcc registration and ringer equivalence number (ren) for the system. Prior to installing your aegis system, please call your tele...

  • Page 26

    Aegis 7000p page 26.