Pacific Energy Alderlea T5 Classic Insert Installation And Operating Instructions Manual

Summary of Alderlea T5 Classic Insert

  • Page 1

    080515-24 alt5.Cpinsb 5055.2031 model: alt5 insert series: d alderlea t5 classic insert important: these instructions are to remain with the homeowner save these instructions installation and operating instructions tested and listed to ulc s628 / ul 1482 meets the u.S. Environmental protection agenc...

  • Page 2: Contents

    2 alt5.Cpinsb 080515-24 ©pacific energy fireplace products ltd. Contents safety .................................................................................................................... 3 clearances .............................................................................................

  • Page 3

    6.5" 16" 20.5" 2" $gmdfhqw :doo 3 alt5.Cpinsb 080515-24 ©pacific energy fireplace products ltd. Safety please read this entire manual before installation and use of this wood burning insert. Failure to follow these instructions could result in property damage, bodily injury or even death. We strongl...

  • Page 4

    4 alt5.Cpinsb 080515-24 ©pacific energy fireplace products ltd. Maintenance checks check the following parts for damage such as cracks, excessive corrosion, burned out sections and excessive warping: (see website for descriptions and more detail) weekly: - firebrick - visual, for cracking. - door ga...

  • Page 5

    5 alt5.Cpinsb 080515-24 ©pacific energy fireplace products ltd. 16” non-combustible fi replace hearth 24 1/2” 21” 18” 8” 8” fireplace hearth requirements: (measured without the insert) the non-combustible fi replace hearth must be raised 2” above an adjacent combustible fl oor and extend 16” in fron...

  • Page 6

    6 alt5.Cpinsb 080515-24 ©pacific energy fireplace products ltd. 29 3/8" 42 1/2" 30 3/8" 42 1/2" 33 1/8" 34 1/8" 9 1/2" 33 5/8" 23 7/8" 10 5/8" 17 5/8" 20 7/8" 17 5/8" 28 3/8" 21 1/2" with regular surround with oversized surround alt5 insert & alt5 classic insert dimensions.

  • Page 7

    7 alt5.Cpinsb 080515-24 ©pacific energy fireplace products ltd. Installation your insert is designed to be installed into a masonry or factory- built, zero-clearance wood burning fi replace. The masonry fi replace must be built according to the requirements of the standard of chimneys, fireplaces, v...

  • Page 8

    8 alt5.Cpinsb 080515-24 ©pacific energy fireplace products ltd. Full flue liner (required in canada) fig #2 this fi replace insert must be installed with a continuous liner of 6” diameter extending from the fi replace insert to the top of the chimney. The chimney liner must conform to the class 3 re...

  • Page 9

    9 alt5.Cpinsb 080515-24 ©pacific energy fireplace products ltd. O/a cover screw o/a cover fig. # 5 fig. # 6 fig. # 7 combustion air consult local building codes regarding combustion air supply. Intake or combustion air can be supplied to the insert in one of two ways: 1) outside air (o/a) supply: re...

  • Page 10

    10 alt5.Cpinsb 080515-24 ©pacific energy fireplace products ltd. Surround assembly and installation 1) remove crate and all plastic packaging. 2) remove top(a) and shields(b). (fig. #8) 3) remove surround top and sides from packaging. 4) remove the surround brackets from the stove(fig. #9) and attac...

  • Page 11

    11 alt5.Cpinsb 080515-24 ©pacific energy fireplace products ltd. Fan removal/installation 1) remove decorative top and both fan shields as specifi ed in “fan speed control relocation” section on page 11. 2) disconnect fan wires as shown in fig #16 from appropri- ate fan that is being replaced. Remov...

  • Page 12

    12 alt5.Cpinsb 080515-24 ©pacific energy fireplace products ltd. 4) loosen the two bolts that secure the ash lip to the fi rebox (fig #22), carefully lift up the ash lip and remove from the fi rebox. 5) loosen the screws on the wire support tabs and turn to remove the wires (fig #23). 6) remove the ...

  • Page 13

    13 alt5.Cpinsb 080515-24 ©pacific energy fireplace products ltd. 9) reconnect the wires to the fans (fig.28) and re-attach thermal snap switch (fig.29). Refi t ash lip, sides and top. Ensure that the power cable is correctly routed through the surround and it is not touching the fi rebox side (fig #...

  • Page 14

    14 alt5.Cpinsb 080515-24 ©pacific energy fireplace products ltd. Operation wood selection this heater is designed to burn natural wood only. Higher efficiency and lower emissions generally result when burning air-dried seasoned hardwoods, as compared to softwoods or too green or freshly cut hardwood...

  • Page 15

    15 alt5.Cpinsb 080515-24 ©pacific energy fireplace products ltd. Ash removal whenever ashes get 3 to 4 inches deep in your fi rebox, and when fi re has burned down and cooled, remove excess ashes. Leave an ash bed approximately 1 inch deep on the fi rebox bottom to help maintain a hot charcoal bed. ...

  • Page 16

    16 alt5.Cpinsb 080515-24 ©pacific energy fireplace products ltd. Chimney fires the result of excessive creosote buildup is a chimney fi re. Chimney fi res are dangerous. Chimney inside temperatures can exceed 2000 degrees f. This causes much higher than normal temperatures in the chimney and on its ...

  • Page 17

    17 alt5.Cpinsb 080515-24 ©pacific energy fireplace products ltd. Maintenance 1. Burn wood only, dry and well seasoned. The denser or heavier the wood when dry, the greater its heat value. This is why hardwoods are generally preferred. Green or wet wood will cause a rapid buildup of creosote. If you ...

  • Page 18

    20 18 alt5.Cpinsb 080515-24 ©pacific energy fireplace products ltd. Item description part no. 1............ Surround, black enamel................. Alt5.Cpsbka .............. Surround, majolica brown enamel . Alt5.Cpsbna .............. Surround, antique white enamel ...Alt5.Cpsawa .............. O/s...

  • Page 19

    19 alt5.Cpinsb 080515-24 ©pacific energy fireplace products ltd. Understanding & operating your pacifi c energy stove the pacifi c energy line of woodstoves is a culmination of years of research and development. Designed to be efficient, clean-burning and user-friendly, this heater will give you yea...

  • Page 20

    Alt5.Cpinsb 080515-24 ©pacific energy fireplace products ltd. 20 troubleshooting problem cause cure excessive creosote 1) wood is too wet - use dry wood buildup 2) turning down air control - do not turn down until: too soon a) there is a good bed of coals b) the wood is charred 3) draft too low - im...

  • Page 21: Alderlea T5 Insert

    21 alt5.Cpinsb 080515-24 ©pacific energy fireplace products ltd. Item size part number n. America a 9” x 4 1/2” x 1 1/4” (230 mm x 115 mm x 32 mm) 5096.99 b 7 1/4” x 4 1/2” x 1 1/4” (184 mm x 115 mm x 32 mm) 245.0 alderlea t5 insert firebrick installation this package contains 18 full-size fi rebric...

  • Page 22: Warranty Information

    22 alt5.Cpinsb 080515-24 ©pacific energy fireplace products ltd. Pacifi c energy limited lifetime warranty wood products pacifi c energy extends the following warranty coverage to the original registered purchaser of the product: ltd lifetime coverage (10 years) limited lifetime coverage is extended...

  • Page 23: Caution

    23 alt5.Cpinsb 080515-24 ©pacific energy fireplace products ltd. Label minimum clearance to combustibles (measured from insert body) dÉgagement minimum aux combustibles a) adjacent sidewall/ 520 mm / 20.5 in paroi latÉrale adjacente b/c) mantel/top facing/ 406 mm / 16 in mantel/ revÊtement supÉrieur...

  • Page 24

    ?pacific energy fireplace products ltd. Pacific energy fireplace products ltd. Www.Pacifi cenergy.Net technical support: 1-250-748-1184 2975 allenby rd., duncan, b.C. V9l 6v8 printed in canada.