Pacific Energy Alderlea T5 Insert Installation And Operating Instructions Manual

Summary of Alderlea T5 Insert

  • Page 1

    150714-24 alt5.Ascinsb 5055.203-bas model: alt5 insert series - d alderlea t5 insert, t5 classic insert important: keep these instructions for future reference. Installation and operating instructions safety notice if this stove is not properly installed, a house fi re may result. For your safety, f...

  • Page 2

    2 alt5.Ascinsb 150714-24 ©pacific energy fireplace products ltd. Contents maintenance checks.......................................................................... 3 maintenance ...................................................................................... 4 baffle removal ..................

  • Page 3

    3 alt5.Ascinsb 150714-24 ©pacific energy fireplace products ltd. Check the following parts for damage such as cracks, excessive corrosion, burned out sections and excessive warping: (see website for descriptions and more detail) weekly: - firebrick - visual, for cracking. - door gasket - sagging, pl...

  • Page 4

    4 alt5.Ascinsb 150714-24 ©pacific energy fireplace products ltd. Maintenance 1. Burn wood only, dry and well seasoned. The denser or heavier the wood when dry, the greater its heat value. This is why hardwoods are generally preferred. Green or wet wood will cause a rapid buildup of creosote. If you ...

  • Page 5

    5 alt5.Ascinsb 150714-24 ©pacific energy fireplace products ltd. In case of a chimney fire 1. Prepare to evacuate to ensure everyone’s safety. Have a well understood plan of action for evacuation. Have a place outside where everyone is to meet. 2. Close down the damper on stove. 3. Call local fi re ...

  • Page 6

    6 alt5.Ascinsb 150714-24 ©pacific energy fireplace products ltd. Operation wood selection this heater is designed to burn natural wood only. Higher efficiency and lower emissions generally result when burning air-dried seasoned hardwoods, as compared to softwoods or too green or freshly cut hardwood...

  • Page 7

    7 alt5.Ascinsb 150714-24 ©pacific energy fireplace products ltd. Blower the alderlea insert comes equipped with twin variable speed circulating air blowers. The blower system is thermostatically controlled for automatic operation, as as well manually with a convenient bypass switch. Blower operation...

  • Page 8

    300mm 600mm 300mm 51mm adjacent w all 8 alt5.Ascinsb 150714-24 ©pacific energy fireplace products ltd. Safety please read this entire manual before installation and use of this wood burning insert. Failure to follow these instructions could result in property damage, bodily injury or even death. We ...

  • Page 9

    9 alt5.Ascinsb 150714-24 ©pacific energy fireplace products ltd. 400mm non-combustible fi replace hearth 622mm 533mm 457mm 200mm 200mm fireplace hearth requirements: (measured without the insert) the non-combustible fi replace hearth must be raised 50mm above an adjacent combustible fl oor and exten...

  • Page 10

    10 alt5.Ascinsb 150714-24 ©pacific energy fireplace products ltd. 746mm 1.08m 772mm 1.08m 841mm 867mm 241mm 854mm 606mm 270mm 448mm 530mm 448mm 721mm 546mm with regular surround with oversized surround alt5 insert & alt5 classic insert dimensions.

  • Page 11

    11 alt5.Ascinsb 150714-24 ©pacific energy fireplace products ltd. Installation warning: under no circumstances is this heater to be installed in a makeshift or “temporary” manner. It may be fi red only after the stove is installed properly. Do not attempt to connect this heater to any air distributi...

  • Page 12

    12 alt5.Ascinsb 150714-24 ©pacific energy fireplace products ltd. Be removed from the smoke shelf and adjacent damper frame if necessary to accommodate a chimney liner, provided that their removal will not weaken the structure of the fi replace and chimney, and will not reduce protection for combust...

  • Page 13

    13 alt5.Ascinsb 150714-24 ©pacific energy fireplace products ltd. Chimney and connector warning: install chimney and all components of chimney system according to chimney manufacturer’s instructions. Connect to a listed chimney complying with the requirements of as/nzs2918/2001 and a chimney suitabl...

  • Page 14

    14 alt5.Ascinsb 150714-24 ©pacific energy fireplace products ltd. O/a cover screw o/a cover fig. # 5 fig. # 6 fig. # 7 two ways: 1) outside air (o/a) supply: remove cover from ash clean out in existing fi replace. Place a rodent screen in place of the cover. Install the insert as described in the in...

  • Page 15

    15 alt5.Ascinsb 150714-24 ©pacific energy fireplace products ltd. 2) remove top(a) and shields(b). (fig. #8) 3) remove surround top and sides from packaging. 4) remove the surround brackets from the stove(fig. #9) and attach to the surround sides as shown in fig. #10. Use the bolts and washers in th...

  • Page 16

    16 alt5.Ascinsb 150714-24 ©pacific energy fireplace products ltd. 2) disconnect fan wires as shown in fig #16 from appropriate fan that is being replaced. Remove thermal switch if needed. (fig #17) 3) remove the two screws securing the fan bracket to the stove using a 7/16” socket or wrench. Reverse...

  • Page 17

    17 alt5.Ascinsb 150714-24 ©pacific energy fireplace products ltd. 5) loosen the screws on the wire support tabs and turn to remove the wires (fig #23). 6) remove the two screws securing the speed controls assembly to the ash lip (fig #24).Remove cover plate on opposite side. 7) remove the control as...

  • Page 18

    18 alt5.Ascinsb 150714-24 ©pacific energy fireplace products ltd. Is important to prevent damage to wires. Surround assembly and installation 1) remove crate and all plastic packaging. 8) route cable from speed control to fan and reattach wire support tabs on the underside of the ash lip. Note wire ...

  • Page 19

    20 19 alt5.Ascinsb 150714-24 ©pacific energy fireplace products ltd. Item description part no. 1............ Regular surround ............................. Alt5.Smbka .............. Surround, black enamel...................... Alt5.Pbka .............. Surround, majolica brown enamel ...... Alt5.Pbna...

  • Page 20

    20 alt5.Ascinsb 150714-24 ©pacific energy fireplace products ltd. 20 item description part no. 1............ Surround, black enamel....................Alt5.Spbka .............. Surround, majolica brown enamel ....Alt5.Spbna .............. O/s surround, black enamel .......Alt5.Spbkosa .................

  • Page 21

    21 alt5.Ascinsb 150714-24 ©pacific energy fireplace products ltd. 21 troubleshooting problem cause cure excessive creosote 1) wood is too wet - use dry wood buildup 2) turning down air control - do not turn down until: too soon a) there is a good bed of coals b) the wood is charred 3) draft too low ...

  • Page 22: Alderlea T5 Insert

    22 alt5.Ascinsb 150714-24 ©pacific energy fireplace products ltd. Item size part number n. America a 230 mm x 115 mm x 32 mm 5096.99 b 184 mm x 115 mm x 32 mm 245.0 alderlea t5 insert firebrick installation this package contains 18 full-size fi rebricks, as well as 1 cut-size brick. With the heater ...

  • Page 23

    23 alt5.Ascinsb 150714-24 ©pacific energy fireplace products ltd. Label 050914 5050.44as model: alderlea t5 series: d type: fireplace insert made in canada maximum average heat output burning hardwood - 10.0 kw overall average efficiency burning hardwood - 67% when tested in accordance with as/nzs 4...

  • Page 24

    ?pacific energy fireplace products ltd. Pacific energy fireplace products ltd. Www.Pacifi cenergy.Net technical support: 1-250-748-1184 2975 allenby rd., duncan, b.C. V9l 6v8 printed in canada.