Pacific Energy BEDFORD A Series Installation And Operating Instructions Manual - Door Installation/removal

Manual is about: DIRECT VENT GAS INSERTS

Summary of BEDFORD A Series

  • Page 1

    Visit www.Pacificenergy.Net for the most recent version of this manual brsl.Bodyb / bdfd.Bodyb model: bristol / bedford series: b direct vent gas inserts 050216-44 warning: if the information in these instructions is not followed exactly a fire or explosion may result causing property damage, person...

  • Page 2: Table of Contents

    Brsl.Bodyb bdfd.Bodyb 5055.633-b table of contents important note for the commonwealth of massachusetts: ...... 3 caution ....................................................................................... 4 safety ....................................................................................

  • Page 3

    Brsl.Bodyb bdfd.Bodyb important note for the commonwealth of massachusetts: from massachusetts rules and regulations 248 cmr 5.08: (a) for all side wall horizontally vented gas fuelled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, inc...

  • Page 4: Hot Glass Will Cause

    Hot glass will cause burns. Do not touch glass until cooled. Never allow children to touch glass. ! Danger a barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appliance and shall be installed for the protection of children and other at-risk individuals. Brs...

  • Page 5: Safety

    Brsl.Bodyb bdfd.Bodyb safety • due to high temperatures, this gas appliance should be located out of traffic and away from furniture and draperies. • children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. • young ch...

  • Page 6: First Fire

    Note: fireplace may take up to 30 seconds to ignite each time the “on” button has been selected brsl.Bodyb bdfd.Bodyb 5055.633-b first fire congratulations on your purchase of a pacifi c energy gas appliance. Your fi replace has been professionally installed by: dealer name: ________________________...

  • Page 7: Remote Control Operation

    Blue back lit lcd display on/off key thermostat key up/down arrow key mode key figure 1: profl ame 2 handset. Off on smart max max key lock low battery alarm room temperature cpi mode dimmer on dimmer on set point: temperature/level/state thermostat off/ on/smart transmission * see notice regarding ...

  • Page 8

    Figure 3: ifc module. Figure 4: on - off switch - battery holder. Figure 5: on - off switch cover. Brsl.Bodyb bdfd.Bodyb 5055.633-b ifc module the proflame 2 integrated fireplace control (ifc) module (figure 3) is a device that allows automatic ignition and pilot flame supervision, and commands the ...

  • Page 9

    The thermostat key (figure 1) on the remote handset needs to be held down. Keep it pressed down and remove one of the three batteries from the remote handset. Simply re-install the battery that was removed and the feature is activated. Use the same procedure to disable the thermostat function. Instr...

  • Page 10

    Flame off flame level 5 flame level max flame level 1 figure 9: flame level control. Room temperature set temperature figure 10: room temperature control. Brsl.Bodyb bdfd.Bodyb 5055.633-b remote flame control the proflame has six (6) flame levels. With the system on, and the flame level at the maxim...

  • Page 11

    Figure 13: comfort fan hi. Figure 14: comfort fan off. Brsl.Bodyb bdfd.Bodyb smart thermostat (transmitter operation) the smart thermostat function adjusts the fl ame height in accordance to the difference between the set point and the room temperatures. As the room temperature gets closer to the se...

  • Page 12

    Figure 17: low battery indication. Brsl.Bodyb bdfd.Bodyb 5055.633-b low battery power detection transmitter the life span of the remote control batteries depends on various factors: quality of the batteries used, the number of ignitions of the heater, the number of changes to the room thermostat set...

  • Page 13: Maintenance

    Brsl.Bodyb bdfd.Bodyb continuous pilot/intermittent pilot (cpi/ipi) selection maintenance caution: turn off gas and electrical power supply (if applicable) and allow ample time for unit to cool before servicing appliance. It is recommended that the fireplace and its venting should be inspected at le...

  • Page 14: Lighting Instructions

    Brsl.Bodyb bdfd.Bodyb 5055.633-b lighting instructions 14 050216-44.

  • Page 15: Fireplace Dimensions

    25.1/8” 20” 16 3/8” 12 5/8” 19 7/8” 18 3/4” 2 1/8” 5 5/8” 15 7/8” ‘ 16 34” 22 5/8” figure 19: bristol dimensions. 33 1/8” 23” 17 3/8” 22 7/8” 17 3/8” 13 5/8” 21 7/8” 2 1/8” 6 1/4” 23 1/2” 17 5/8” 30 5/8” figure 20: bedford dimensions. Brsl.Bodyb bdfd.Bodyb fireplace dimensions bristol: bedford: 15 5...

  • Page 16

    Figure 21: cavity dimensions. Brsl.Bodyb bdfd.Bodyb 5055.633-b existing fireplace preparation the bristol and bedford gas inserts are certified to be installed into pre-existing approved fire place cavities. The minimum cavity requirements are listed in figure 21 below. Before installing the bristol...

  • Page 17: Clearances to Combustibles

    Figure 22: mantel clearances. 8” 8” figure 23: sidewall clearances. Brsl.Bodyb bdfd.Bodyb clearances to combustibles minimum hearth depth16” as measured from glass determine the mantel height from the fl oor (a,b & c) and depth from the wall (d,e & f) according to the fi replace model, the fi replac...

  • Page 18: Venting

    Figure 24: flue adaptor plate conections. Brsl.Bodyb bdfd.Bodyb 5055.633-b figure 26: co-linear venting. Venting note: the following simpson duravent kits are recommended for use with this appliance. High-wind (bristol 46dva-cl33) (bedford 46dva-cl34) prairie co-linear kit (bristol 46dva-cl33p) (bed...

  • Page 19: Plumbing and Electrical

    Figure 27: gas and electrical connections. Brsl.Bodyb bdfd.Bodyb plumbing and electrical note: installation requires that an electrical outlet be in close proximity to the gas insert. To make the required electrical and gas connections start by positioning the gas insert within the existing fireplac...

  • Page 20: Gas Supply

    Brsl.Bodyb bdfd.Bodyb 5055.633-b gas supply gas pressure requirements input pressure natural gas propane minimum 5.0” wc 11.0” wc maximum 13.9” wc 13.9” wc manifold pressure high 3.5” wc 10” wc low 1.6” wc 6.4” wc gas pressure check / output / efficiency bristol gas orifice output afue ng 1.98mm 18,...

  • Page 21: Pilot Adjustment

    Figure 28: valve location. Figure 29: valve. Brsl.Bodyb bdfd.Bodyb gas pressure testing procedure battery holder note: to test the gas pressure, turn off the gas supply to the appliance before loosening test point screws. Verify gas pressures with the fireplace lit and at the highest setting. 1. Rem...

  • Page 22: Propane Conversion

    Pilot assembly orifice figure 30: burner orifice and pilot. Figure 32: pilot. Figure 33: venturi opening. Brsl.Bodyb bdfd.Bodyb 5055.633-b propane conversion pilot orifice sizes ng - #62 lp - #35 before starting the conversion make sure to shut off the gas supply to the unit and allow fireplace to c...

  • Page 23: Door Installation/removal

    Figure 34: adjustment feet on the bottom rear of unit. Figure 35: releasing door screws. Brsl.Bodyb bdfd.Bodyb door installation/removal note: in the event that the door glass breaks, the complete door assembly must be replaced. See “replacement parts” on page 39 for the appropriate part number. Ins...

  • Page 24

    Figure 37: surround and lintel tab. Surround installation instructions figure 36: door. Figure 38: top of surround fi tting inside the baffl e during installation. Figure 39: surround in place (backing not shown). Brsl.Bodyb bdfd.Bodyb 5055.633-b the surround cover (figure 36) attaches to the lintel...

  • Page 25: Surround Front Dimensions

    24” 20 1/2” 24” 20 1/2” 32” 23 1/2” surround front dimensions brsl.Bodyb bdfd.Bodyb brca.18lfbkb - louvered black brca.18lfgyb - louvered grey bristol fronts bedford fronts brca.18cfbkb - contoured black brca.18cfgyb - contoured grey bdcd.30lfbkb - louvered black bdcd.30lfgyb - louvered grey bdcd.30...

  • Page 26: Surround Dimensions

    32” 24 7/16” 32” 24 7/16” 40” 27 9/16” 40” 29 9/16” 48” 30 9/16” 40” 27 1/2” surround dimensions brsl.Bodyb bdfd.Bodyb 5055.633-b bdfd.30bsbbka - beveled backing plate - black bdfd.30bsbgya - beveled backing plate - grey brsl.18osfsbbka - oversize backing plate - black brsl.18osfsbgya - oversize bac...

  • Page 27: Battery Holder

    Figure 40: older riveted bracket. Figure 41: new bracket. Figure 42: new bracket with battery. Brsl.Bodyb bdfd.Bodyb bdfd.30osfsbbka - oversize backing plate - black bdfd.30osfsbgtya - oversize backing plate - grey bdfd.30fsbbka - regular backing plate - black bdfd.30fsbgya - regular backing plate -...

  • Page 28: Fan Removal / Installation

    Figure 43: door bolts location. Figure 44: logs in place. Figure 45: left large ember block removed. Brsl.Bodyb bdfd.Bodyb 5055.633-b fan removal / installation 1. Make sure that the gas and electrical supply is shut off. Locate and remove the two 3/8” bolts securing the bottom of door as seen in fi...

  • Page 29

    Figure 46: burner hold down screw location. Figure 47: removing upper baffle. Figure 48: removing burner plate. Figure 49: removing side firebox panel. Figure 50: removing rear firebox panel. Screws brsl.Bodyb bdfd.Bodyb removing the burner and burner tray. 1. Remove the screw holding the burner to ...

  • Page 30

    Figure 54: nut location. Figure 51: back ledge removal. Figure 52: removing base plate. Figure 53: base plate moved to the right side. Brsl.Bodyb bdfd.Bodyb 5055.633-b 6. Remove two screws which hold the back ledge (figure 51) in place and remove. 7. Remove the approximately 25 screws hold the base ...

  • Page 31

    Figure 55: removing blower fan. Figure 56: blower fan. Brsl.Bodyb bdfd.Bodyb need to disconnect any of the electrical or gas fittings. 9. The fan is located inside the opening and toward the rear of the firebox. A 3/8” nut holds the fan assembly onto a threaded post. Remove the nut and gently extrac...

  • Page 32: Panel Installation / Removal

    Figure 57: panel set. Figure 58: rear panel. Figure 59: side panel. Brsl.Bodyb bdfd.Bodyb 5055.633-b panel installation / removal installation 1. Insert back panel so that it is sitting on ledge at the back of the fi rebox as shown in figure 58. 2. Insert fi rst side panel by inserting the front edg...

  • Page 33

    Figure 60: removing baffle. Figure 61: baffle mount screw location. Figure 62: air deflector. Brsl.Bodyb bdfd.Bodyb installation position the air deflector in the fireplace as seen in (figure 62) and secure with two screws using a screwdriver. Removal remove the two screws seen in (figure 62) using ...

  • Page 34

    Burner tray installation / removal screws figure 63: burner tray. Figure 64: burner. Figure 65: burner components. Brsl.Bodyb bdfd.Bodyb 5055.633-b installation place burner in firebox so that the venturi is over top of the orifice. To secure burner insert screw using a screwdriver as seen in figure...

  • Page 35

    Figure 66: log set. Figure 67: rear log installation. Figure 68: front log installation. Figure 69: decorative log installation. Figure 70: ember placement. Figure 71: complete log set. Brsl.Bodyb bdfd.Bodyb log set installation / removal installation 1. Position rear log against the back fi rebox a...

  • Page 36

    Figure 72: rustic log set. Figure 73: rustic rear log installation. Figure 74: rustic front log installation. Figure 75: rustic side log installation. Figure 76: rustic decorative log installation. Figure 77: rustic complete log set. Brsl.Bodyb bdfd.Bodyb 5055.633-b rustic log set installation / rem...

  • Page 37

    Figure 78: glass burner kit. Figure 79: air deflector - glass burner. Screws figure 80: burner tray - glass. Figure 81: glass installation. Figure 82: rock placement. Brsl.Bodyb bdfd.Bodyb glass burner installation / removal air deflector installation / removal installation position the air deflecto...

  • Page 38: Damper/air Shutter

    Damper/air shutter figure 83: air shutter. Brsl.Bodyb bdfd.Bodyb 5055.633-b bristol aesthetic components brsl.Bodyb the bristol and bedford fireplaces both come with an adjustable damper that can limit the flow of intake air. This damper is located behind the air deflector at the rear of the inner f...

  • Page 39: Replacement Parts

    Brsl.Bodyb bdfd.Bodyb replacement parts louvered front - black ............................Brca.18lfbkb louvered front - grey ............................ Brca.18lfgyb contoured front - black .........................Brca.18cfbkb contoured front - grey ..........................Brca.18cfgyb descript...

  • Page 40: Wiring Diagram

    Brsl.Bodyb bdfd.Bodyb 5055.633-b wiring diagram caution: label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. 40 050216-44.

  • Page 41: Bristol Rating Label

    B this appliance is equipped for use with / cet appareil est Équipé pour utilise avec : natural gas lp-gas gaz naturel lp gaz for use with/ en case d’emploi avec: natural gas/ du gaz naturel lp gas/ du gaz lp minimum supply pressure / pression minimum d’alimentation: (for the purpose of input adjust...

  • Page 42: Bedford Rating Label

    B this appliance is equipped for use with / cet appareil est Équipé pour utilise avec : natural gas lp-gas gaz naturel lp gaz for use with/ en case d’emploi avec: natural gas/ du gaz naturel lp gas/ du gaz lp minimum supply pressure / pression minimum d’alimentation: (for the purpose of input adjust...

  • Page 43

    Brsl.Bodyb bdfd.Bodyb 43 5055.633-b 050216-44.

  • Page 44

    © 2016 copyright pacific energy fireplace products ltd. Reproduction, adaptation, or translation without prior written permission is prohibited except as allowed under the copyright laws. For technical support, please contact your retailer web site: www. Pacificenergy.Net 2975 allenby rd., duncan, b...