Pacific Energy BEDFORD A Series Installation And Operating Instructions Manual - Battery Holder

Manual is about: DIRECT VENT GAS INSERTS

Summary of BEDFORD A Series

  • Page 1

    Brsl.Bodyb bdfd.Bodyb bristol & bedford installation and operating instructions model: bristol / bedford series: b direct vent gas inserts 140515-44 5055.633-b warning: if the information in these instructions is not followed exactly a fire or explosion may result causing property damage, personal i...

  • Page 2

    Brsl.Bodyb bdfd.Bodyb important note for the commonwealth of massachusetts: from massachusetts rules and regulations 248 cmr 5.08: (a) for all side wall horizontally vented gas fuelled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, inc...

  • Page 3: Table Of Contents

    Brsl.Bodyb bdfd.Bodyb note for massachusetts ..................................... 2 owners information caution .............................................................. 4 safety ................................................................ 5 first fire .........................................

  • Page 4: Hot Glass Will Cause

    Hot glass will cause burns. Do not touch glass until cooled. Never allow children to touch glass. ! Danger a barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appliance and shall be installed for the protection of children and other at-risk individuals. Brs...

  • Page 5: Safety

    Brsl.Bodyb bdfd.Bodyb safety • due to high temperatures, this gas appliance should be located out of traffic and away from furniture and draperies. • children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. • young ch...

  • Page 6: Note: Fireplace May

    Note: fireplace may take up to 30 seconds to ignite each time the “on” button has been selected brsl.Bodyb bdfd.Bodyb first fire congratulations on your purchase of a pacific energy gas appliance. Your fireplace has been professionally installed by: dealer name: _______________________________ phone...

  • Page 7

    Brsl.Bodyb bdfd.Bodyb remote control operation figure 1: proflame transmitter figure 2: transmitter lcd display system description the proflame2 remote control system consists of two elements: 1. Proflame2 transmitter. 2. Proflame2 integrated fireplace control (ifc) board and a wiring harness to con...

  • Page 8: Ifc Module

    3. Ifc (integrated fireplace control) module. Figure 4. On/off switch. Position switch in the middle to use the hand-held remote control switch. Brsl.Bodyb bdfd.Bodyb ifc module the proflame2 integrated fireplace control (ifc) module (fig. 3) is a device that allows automatic ignition and pilot flam...

  • Page 9

    Brsl.Bodyb bdfd.Bodyb figure 6: display in fahrenheit figure 7: display in celsius temperature indication display with the system in the “off” position, press the thermostat key and the mode key at the same time. Look at the lcd screen on the transmitter to verify that a c or f is visible to the rig...

  • Page 10

    Brsl.Bodyb bdfd.Bodyb figure 9: figure 10 figure 11: smart flam function figure 12 remote flame control the proflame has six (6) flame levels. With the system on, and the flame level at the maximum in the appliance, pressing the down arrow key once will reduce the flame height by one step until the ...

  • Page 11

    Brsl.Bodyb bdfd.Bodyb comfort fan speed control if the heater is equipped with a hot air circulating fan, the speed of the fan can be con- trolled by the proflame2 system. The fan speed can be adjusted through six (6) speeds. To activate this function use the mode key (fig. 1) to index to the fan co...

  • Page 12: Warnings And Cautions

    Brsl.Bodyb bdfd.Bodyb warnings and cautions low battery power detection transmitter the life span of the remote control batteries depends on various factors: quality of the batteries used, the number of ignitions of the heater, the number of changes to the room thermostat set point, etc. When the re...

  • Page 13: Maintenance

    Brsl.Bodyb bdfd.Bodyb maintenance owner’s information turn off gas and electrical power supply (if applicable) and allow ample time for unit to cool before servicing appliance. It is recommended that the fireplace and its venting should be inspected at least once a year by a qualified service person...

  • Page 14: Lighting  Instructions

    Brsl.Bodyb bdfd.Bodyb lighting instructions owner’s information 14 140515-44 5055.633-b.

  • Page 15: Fireplace  Dimensions

    25.1/8” 20” 16 3/8” 12 5/8” 19 7/8” 18 3/4” 2 1/8” 5 5/8” 15 7/8” ‘ 16 34” 22 5/8” 33 1/8” 23” 17 3/8” 22 7/8” 17 3/8” 13 5/8” 21 7/8” 2 1/8” 6 1/4” 23 1/2” 17 5/8” 30 5/8” brsl.Bodyb bdfd.Bodyb fireplace dimensions bristol: bedford: figure 16: bristol dimensions figure 17: bedford dimensions instal...

  • Page 16

    Brsl.Bodyb bdfd.Bodyb existing fireplace preparation the bristol and bedford gas inserts are certified to be installed into pre-existing approved fire place cavities. The minimum cavity requirements are listed in figure 18 below. Before installing the bristol or bedford inserts have the chimney swep...

  • Page 17: Clearances to Combustibles

    Brsl.Bodyb bdfd.Bodyb clearances to combustibles 8” figure 19: mantel clearances figure 20: sidewall clearances * mantel clearance flat surround * mantel clearance bevelled surround ** mantel depth minimum hearth depth16” as measured from glass installer information bristol bedford louvere d clean b...

  • Page 18: Venting

    Brsl.Bodyb bdfd.Bodyb venting note: the following simpson duravent kits are recommended for use with this appliance. High-wind (bristol 46dva-cl33) (bedford 46dva-cl34) prairie co-linear kit (bristol 46dva-cl33p) (bedford 46dva-cl34p) only certified venting systems or components may be installed wit...

  • Page 19

    Brsl.Bodyb bdfd.Bodyb plumbing and electrical figure 24: gas and electrical connections note: installation requires that an electrical outlet be installed into existing fireplace cavity before insert is installed. To make the required electrical and gas connections start by positioning the gas inser...

  • Page 20: Gas Supply

    Brsl.Bodyb bdfd.Bodyb gas supply warning: the gas tray including gasket must be reinstalled after conversion/installation or servicing has been completed. Gas pressure requirements input pressure natural gas propane minimum 5.0” wc 11.0” wc maximum 13.9” wc 13.9” wc manifold pressure high 3.5” wc 10...

  • Page 21: Pilot Adjustment

    Brsl.Bodyb bdfd.Bodyb gas pressure testing procedure battery box note: to test the gas pressure, turn off the gas supply to the appliance before loosening test point screws. Verify gas pressures with the fireplace lit and at the highest setting. 1. Remove door (fig. 25) and locate the valve as seen ...

  • Page 22: Propane  Conversion

    Brsl.Bodyb bdfd.Bodyb propane conversion figure 28: pilot pilotorificesizes ng - #62 lp - #35 figure 29: venturi opening before starting the conversion make sure to shut off the gas supply to the unit and allow fireplace to cool to room temperature. T o convert the gas fireplace insert from natural ...

  • Page 23: Door Installation/removal

    Brsl.Bodyb bdfd.Bodyb door installation/removal note: in the event that the door glass breaks, the complete door assembly must be replaced. See replacement parts list for the appropriate part number. Installation 1. Position the door so that the doors upper bracket is positioned overtop of the lip o...

  • Page 24

    Surround installation instructions brsl.Bodyb bdfd.Bodyb the surround cover (fig.32) attaches to the lintel once the decorative backing plate has been installed. The surround easily fits into place by connecting all four of its hooks to the lintels four tabs (fig.33). Figure 34: top of surround fitt...

  • Page 25

    24” 20 1/2” 24” 20 1/2” 32” 23 1/2” brsl.Bodyb bdfd.Bodyb brca.18lfbkb-louveredblack brca.18lfgyb-louveredgrey figure 36: fronts sales codes bristol fronts bedford fronts brca.18cfbkb-contouredblack brca.18cfgyb-contouredgrey bdcd.30lfbkb-louveredblack bdcd.30lfgyb-louveredgrey bdcd.30cfbkb-contoure...

  • Page 26

    32” 24 7/16” 32” 24 7/16” 40” 27 9/16” 40” 29 9/16” 48” 30 9/16” 40” 27 1/2” brsl.Bodyb bdfd.Bodyb bdfd.30bsbbka-beveledbackingplate-black bdfd.30bsbgya-beveledbackingplate-grey brsl.18osfsbbka-oversizebackingplate-black brsl.18osfsbgya-oversizebackingplate-grey bdfd.30osfsbbka-oversizebackingplate-...

  • Page 27: Battery Holder

    Brsl.Bodyb bdfd.Bodyb a new battery holder bracket replaces the older one in the series a fireplaces. The older one (fig. 38) was riveted into place while the new series b bracket (fig. 39) is screwed into place. Figure 38: older riveted bracket. Figure 39: new bracket. Figure 40: new bracket with b...

  • Page 28: Fan Removal / Installation

    Brsl.Bodyb bdfd.Bodyb fan removal / installation figure 41 figure 42 figure 43 1. Make sure that the gas and electrical supply is shut off. Locate and remove the two 3/8” bolts securing the bottom of door as seen in figure 41 2. Tilt the bottom of the door away from the appliance and lift the door o...

  • Page 29

    Brsl.Bodyb bdfd.Bodyb figure 44 removing the burner and burner tray. 1. Remove the screw holding the burner to the burner tray (figure 44). 2. Remove two screws from the upper baffle and remove (fig. 45) figure45 figure 46 3. Remove two screws from the burner plate (fig. 46) and remove. 4. Remove th...

  • Page 30

    Brsl.Bodyb bdfd.Bodyb figure 51 figure 52 figure 50 5. Remove two screws which hold the back ledge (fig.50) in place and remove. 6. Remove the approximately 25 screws hold the base plate (fig. 51) to the frame of the fi rebox. 7. Gently remove the base plate (fig. 52) and set aside to the right hand...

  • Page 31

    Brsl.Bodyb bdfd.Bodyb 8. The fan is located inside the opening and toward the rear of the firebox. A 3/8” nut holds the fan assembly onto a threaded post. Remove the nut and gently extract the fan assembly from the fire box (fig. 54) be careful not to accidentally catch any other wires while the fan...

  • Page 32: Panel Installation / Removal

    Brsl.Bodyb bdfd.Bodyb note: air deflector from burner kit needs to be installed before panels. See burner kit installation. Panel installation / removal installation 1. Insert back panel so that it is sitting on ledge at the back of the firebox as shown in figure 57. 2. Insert first side panel by in...

  • Page 33

    Brsl.Bodyb bdfd.Bodyb air deflector installation / removal installation position the air deflector in the fireplace as seen in figure 60 and secure with two screws using a screw- driver. Removal remove the two screws seen in figure 60 using a screwdriver, and remove the air deflector from fireplace....

  • Page 34

    Brsl.Bodyb bdfd.Bodyb installer information log set installation / removal installation 1. Position rear log against the back firebox as seen in figure 65. 2. Position front log just behind the front burner tube as seen in figure 66. 3. Position log 3 with the thin end of the log resting on top of t...

  • Page 35

    Installer information brsl.Bodyb bdfd.Bodyb rustic log set installation / removal installation 1. Position rear logs #1 and #2 against the back fire- box as seen in figure 71. 2. Position front logs #3 and #4 between the front burner tubes as seen in figure 72. 3. Position side logs #5; #6 as seen i...

  • Page 36

    Brsl.Bodyb bdfd.Bodyb installer information glass burner installation / removal air deflector installation / removal installation position the air deflector in the fireplace as seen in figure 77 and secure with two screws using a screwdriver. Removal remove the two screws seen in figure 77 using a s...

  • Page 37: Damper/air Shutter

    Damper/air shutter brsl.Bodyb bdfd.Bodyb the bristol and bedford fireplaces both come with an adjustable damper that can limit the flow of intake air. This damper is located behind the air deflector at the rear of the inner firebox. Sometimes on installations that involve vertical venting configurat...

  • Page 38: Replacement Parts

    Brsl.Bodyb bdfd.Bodyb installer information replacement parts louvered front - black ............................ Brca.18lfbkb louvered front - grey.............................. Brca.18lfgyb contoured front - black ...........................Brca.18cfbkb contoured front - grey ........................

  • Page 39: Wiring  Diagram

    Brsl.Bodyb bdfd.Bodyb wiring diagram figure 82: wiring diagrams caution: label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Regular backing plate - black ...............Bdfd.30fsbbka regul...

  • Page 40: Bristol  Rating  Label

    B this appliance is equipped for use with / cet appareil est Équipé pour utilise avec : natural gas lp-gas gaz naturel lp gaz for use with/ en case d’emploi avec: natural gas/ du gaz naturel lp gas/ du gaz lp minimum supply pressure / pression minimum d’alimentation: (for the purpose of input adjust...

  • Page 41: Bedford  Rating  Label

    B this appliance is equipped for use with / cet appareil est Équipé pour utilise avec : natural gas lp-gas gaz naturel lp gaz for use with/ en case d’emploi avec: natural gas/ du gaz naturel lp gas/ du gaz lp minimum supply pressure / pression minimum d’alimentation: (for the purpose of input adjust...

  • Page 42

    Brsl.Bodyb bdfd.Bodyb installer information 42 140515-44 5055.633-b.

  • Page 43

    Brsl.Bodyb bdfd.Bodyb installer information 43 5055.633-b 140515-44.

  • Page 44

    ? 2015 copyright pacific energy fireplace products ltd. Reproduction, adaptation, or translation without prior written permission is prohibited except as allowed under the copyright laws. Installer for technical support, please contact your retailer web site: www. Pacificenergy.Net 2975 allenby rd.,...