Pacific Energy ESPR.BODYB Installation And Operating Instructions Manual - Warnings and Cautions

Manual is about: ZERO CLEARANCE FIREPLACE

Summary of ESPR.BODYB

  • Page 1

    Installer: leave this manual with the appliance. Consumer: retain this manual for future reference. This appliance is suitable for installation in a bedroom or bed sitting room. Esprit installation and operating instructions visit www. Pacificenergy.Net for the most recent version of this manual mod...

  • Page 2: Table of Contents

    Table of contents important note for the commonwealth of massachusetts ......................... 3 caution ....................................................................4 safety ......................................................................5 first fire ....................................

  • Page 3

    Important note for the commonwealth of massachusetts from massachusetts rules and regulations 248 cmr 5.08: (a) for all side wall horizontally vented gas fuelled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or o...

  • Page 4: Caution

    Caution this fireplace is equipped with a micro mesh safety screen for your protection and must be installed with the unit. Removal of the safety screen will cause the fireplace to become a burn and fire hazard. For your safety - do not install or operate your pacific energy fireplace without first ...

  • Page 5: Safety

    Safety • due to high temperatures, this gas appliance should be located out of traffic and away from furniture and draperies. • children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. • young children should be caref...

  • Page 6: First Fire

    Congratulations on your purchase of a pacific energy gas appliance. Your fireplace has been professionally installed by: dealer name: ___________________________________________________ phone number:___________________________________________________ if you discover any problems with your gas applia...

  • Page 7: Remote Control Operation

    Blue back lit lcd display on/off key thermostat key up/down arrow key mode key figure 1: proflame 2 handset. Off on smart max key lock low battery alarm room temperature cpi mode flame level set point: temperature/level/state thermostat off/ on/smart transmission comfort fan figure 2: proflame 2 lcd...

  • Page 8

    Ifc module the proflame 2 integrated fireplace control (ifc) module (figure 3) is a device that allows automatic ignition and pilot flame supervision, and commands the functions of the hearth fireplace. It’s configured to control the on/off main burner operation, giving the choice of both ipi (inter...

  • Page 9

    Temperature indication display with the system in the “off” position, press the thermostat key and the mode key at the same time. Look at the lcd screen on the transmitter to verify that a c or f is visible to the right of the room temperature display (figure 6 or figure 7). Turn on the fireplace wi...

  • Page 10

    Remote flame control the proflame2 has six (6) flame levels. With the system turned on, and the flame level at maximum in the fireplace, press the down arrow key once to reduce the flame height by one step until the flame is turned off. The up arrow key will increase the flame height each time it is...

  • Page 11

    Figure 13: comfort fan control. Figure 14: ipi cpi selection. Comfort fan speed control if the fireplace is equipped with a hot air circulating fan, the speed of the fan can be controlled by the proflame system. The fan speed can be adjusted through six (6) speeds. To activate this function use the ...

  • Page 12: Warnings and Cautions

    Figure 15: low battery icon. Warning fire hazard. Can cause severe injury or death the receiver causes ignition of the appliance. The appliance can turn on suddenly. Keep away from the appliance burner when operating the remote system or activating manual bypass of the remote system. Warning shock h...

  • Page 13: Maintenance

    Ignitor hood figure 17: esprit pilot assembly.Ai maintenance turn off gas and electrical power supply (if applicable) and allow ample time for unit to cool before servicing appliance. It is recommended that the fireplace and its venting should be inspected at least once a year by a qualified service...

  • Page 14: Lighting Instructions

    Lighting instructions 14 5056.201-a esprit 280617-40

  • Page 15: Fireplace Dimensions

    10” 254 mm 19” 482 mm 29 1/4” 725 mm 33 1/8” 841 mm 32” 813 mm 34 5/16” 871 mm 40 1/8” 1020 mm 43 3/8” 1101 mm 15 3/4” 400 mm figure 18: esprit dimensions. 48” 1219 mm 24” 610 mm 33 5/8” 854 mm 1 1/8” (29 mm) minimum non-combustible combustible 19 1/2” 495 mm figure 19: framing and finishing dimensi...

  • Page 16

    24” 610 mm 48” 1220 mm 33 5/8” 854 mm 1 1/8” 29 mm minimum combustible non combustible figure 20: framing at the corner. Figure 21: minimum clearance corner framing. 16 5056.201-a esprit 280617-40

  • Page 17: Clearances to Combustibles

    Mantel (reference point) 36” min. 26” min. Louvered surround top of glass (reference point) figure 22: minimum distance from top of the glass to ceiling. 36” min. Figure 23: front and side dimensions. Clearances to combustibles minimum clearance to combustible materials enclosed side wall 1.75” encl...

  • Page 18: Locating The Fireplace

    Figure 24: common installation options. 33 5/8” 854mm 45” 1143mm figure 25: framing dimensions. Locating the fireplace in planning the installation for the fireplace, it is necessary to determine where the unit is to be installed, location of vent system and where gas supply piping may be plumbed. V...

  • Page 19

    Surround base screen frame screen faceplate figure 26: louvered surround. Surround base faceplate screen with frame figure 27: clean face surround. Surround installation instructions installation 1. Fasten the surround base to the fireplace using supplied screws and mounting holes located along the ...

  • Page 20

    20 7/8” 530 mm 39 1/2” 990 mm 22 1/2” 559 mm 42 1/4” 1067 mm 1 5/8” 41 mm figure 29: esprit straight edge surround dimensions. 20 5056.201-a esprit 280617-40

  • Page 21: Venting

    35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 esprit linear fireplace venting chart venting horizontal run ve nt ing ve rt ic al ri se no venting option no venting option venting envelope ex ha u s...

  • Page 22

    M k i a v g g h a j v g a b c a v v a v b f b l v e v v v d fixed closed fixed closed open- able open- able air supply inlet vent terminal gas meter area where terminal is not permitted b b vent terminal minimum clearances this fireplace is certified for use with 4” x 6-5/8”coaxial venting component...

  • Page 23: Venting Components

    Figure 30: 4”x 6-five eights” rigid piping cross reference chart. Figure 31: 4”x6-five eigths” rigid pipe components cross reference chart. ^ a vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves both dwellings* ** onl...

  • Page 24: Plumbing and Electrical

    Figure 32: gas connection. Figure 33: electrical connection. Plumbing and electrical gas connection to make the required electrical and gas connections, start by positioning the gas fireplace. Connect the gas supply line to the 1/2” fitting that located on a shut off valve bracket as seen in figure ...

  • Page 25: Gas Supply

    Gas supply gas pressure check gas pressure requirements input pressure natural gas propane minimum 5.0” wc 11.0” wc maximum 13.9” wc 13.9” wc manifold pressure high 3.5” wc 10” wc low 1.6” wc 6.4” wc gas orifice output afue ng 2.55mm 30,000 btu/hr max. 75% 22,000 btu/hr min. Lp 1.52mm 26,000 btu/hr ...

  • Page 26

    Venturi adjustment screw figure 34: gas valve location. Gas pressure testing procedure note: to test the gas pressure, turn off the gas supply to the appliance before loosening test point screws. Verify gas pressures with the fireplace lit and at the highest setting. 1. Remove window surround and lo...

  • Page 27: Propane Conversion

    Pilot orifice figure 36: orifice and pilot. Figure 37: pilot hood removal. Venturi shutter figure 38: venturi shutter. Propane conversion before starting the conversion make sure to shut off the gas supply to the unit and allow fireplace to cool to room temperature. To convert the gas fireplace from...

  • Page 28: Door Installation/removal

    Door handles figure 39: door handles. Figure 40: fan installation and removal. Door installation/removal fan installation / removal installation 1. Place the door in the slot at the bottom of the firebox opening. He door against the firebox. Push 3 levers at the top of the door to secure the door. R...

  • Page 29: Panel Installation / Removal

    1 2 3 4 figure 41: panel set. Back panel figure 42: back panel. Side panel figure 43: side panel. Baffle figure 44: baffle mounts. Fan removal before fireplace installation. 1. Remove fan panel at the rear side of the fireplace as seen in figure 40. 2. Disconnect fan electrical wires and remove fan ...

  • Page 30

    Burner tray screws figure 45: burner tray. Screws to secure burner figure 46: burner. Figure 47: ember placement. Pilot air opening figure 48: pilot and air opening. Burner and tray installation / removal burner tray installation / removal installation place the burner tray in the fireplace. Turn of...

  • Page 31

    Figure 49: log set. 1 2 figure 50: rear logs 1 and 2. 3 figure 51: rear log number 3. 6 figure 52: left side log number 6. 4 5 figure 53: front logs numbers 4 and 5. 7 figure 54: center log number 7. Figure 55: completed log set up. Log set installation / removal place the logs #1 and #2 as seen in ...

  • Page 32

    Figure 56: glass media installation. Figure 57: rock set installation. Glass burner kit installation / removal glass installation to install the glass, evenly spread a thin layer of crushed glass across the entire burner pan as seen in figure 56 to install the optional rock set, simply place desired...

  • Page 33

    Damper figure 58: air damper location. Damper figure 59: damper detail. Intake air damper installation the esprit fireplaces come with the damper that can limit the flow of intake air. This damper is located behind the air baffle at the top of the inner firebox. Sometimes on installations that invol...

  • Page 34: Replacement Parts

    Replacement parts esprit linear gas fireplace sales codes unit part sku esprit linear gas fireplace ...................................... Espr.Bodya ....................................1203003 replacement parts esprit replacement door with glass ........................ Perp.3008 .....................

  • Page 35: Wiring Diagram

    Wiring diagram caution: label all wires prior to disconnection when servic- ing controls. Wiring errors can cause improper and danger- ous operation. Verify proper operation after servicing. Lamp comfort fan pilot burner diagnostics interface 35 280617-40 5056.201-a esprit.

  • Page 36: Rating Label

    B this appliance is equipped for use with / cet appareil est Équipé pour utilise avec : natural gas lp-gas gaz naturel lp gaz for use with/ en case d’emploi avec: natural gas/ du gaz naturel lp gas/ du gaz lp minimum supply pressure / pression minimum d’alimentation: (for the purpose of input adjust...

  • Page 37

    37 280617-40 5056.201-a esprit.

  • Page 38

    38 5056.201-a esprit 280617-40

  • Page 39

    39 280617-40 5056.201-a esprit.

  • Page 40

    © 2017 copyright pacific energy fireplace products ltd reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copy- right laws. For technical support, please contact your retailer web site: www.Pacificenergy.Net 2975 allenby rd., duncan, ...