Pacific Energy ESTATE Operating Instructions Manual - Door Installation/removal
26
INSTALLER
INFORMATION
Door Installation/Removal
Installation
1. Position the door so that the doors upper bracket is
positioned overtop of the lip on top of the firebox.
2. Lower the bottom edge of the door and secure it with
3/8”
bolts to the relief arms as shown in figure 28.
Removal
1. Locate and remove the
two 3/8” bolts securing the bottom
of door as seen in figure 28.
2. Tilt the bottom of the door away from the appliance and lift
the door off.
Figure 28: Door
Fan Installation / Removal
Removal
1. Pull the inner firebox out of fireplace cavity until the fan
access panel on the back of the fireplace can be
accessed as in Figure 29.
2.
Turn off main gas supply to unit and disconnect 3/8”
flex tubing from inner firebox. Also disconnect the
power cord from inner firebox.
3. Remove screws from access panel and pull fan out of
unit disconnecting wires to remove completely.
4. Insert all screws in fan access panel to attach the fan
to the unit, as in Figure 29.
5. Reconnect the gas supply and power and push the
inner firebox back into the fireplace cavity.
Installation
(before fireplace installation)
1. Remove back lower half of fireplace casing to reach fan access panel.
2. Connect Wiring to the fan and insert into the fireplace through the back of the unit.
3. Insert all screws in fan access panel to attach the fan to the unit, as in Figure 29.
4. Reinstall back lower half of fireplace casing.
Installation
(after fireplace installation)
1. Pull the inner firebox out of fireplace cavity until the fan access panel on the back of the
fireplace can be accessed as in Figure 29.
2.
Turn off main gas supply to unit and disconnect 3/8” flex tubing from inner firebox. Also
disconnect the power cord from inner firebox.
3. Connect Wiring to the fan and insert into the fireplace through the back of the unit.
4. Insert all screws in fan access panel to attach the fan to the unit, as in Figure 29.
5. Reconnect the gas supply and power and push the inner firebox back into the fireplace cavity.
Figure 29: Fan Access Panel