Pacific Energy NEO 1.6 NEWCASTLE Installation And Operating Instruction

Summary of NEO 1.6 NEWCASTLE

  • Page 1

    130715-24 neo16 - newcastle 5055.855 installation and operating instructions safety notice if this stove is not properly installed, a house fire may result. For your safety, follow the installation instructions. Contact local building or fire officials about restrictions and installation inspection ...

  • Page 2: Contents

    2 130715-24 ©pacific energy fireplace products ltd. Please save these instructions this manual describes the installation and operation of the pacific energy, newcastle 1.6 freestanding wood stove. This woodstove meets the 2015 u.S. Environmental protection agency's crib wood emission limits for woo...

  • Page 3

    130715-24 3 ©pacific energy fireplace products ltd. Chimney smoke and creosote formation when wood is burned slowly, it produces tar and other or- ganic vapours, which combine with expelled moisture to form creosote. The creosote vapours condense in the relatively cool chimney flue of a slow burning...

  • Page 4

    4 130715-24 ©pacific energy fireplace products ltd. Caution: never use gasoline, gasoline type lantern fuel, kerosene, charcoal lighter fluid or similar liquids to start or "freshen up" a fire in this woodstove. Keep all such liquids well away from the woodstove while it is in use. Caution: hot whil...

  • Page 5

    130715-24 5 ©pacific energy fireplace products ltd. 2. Too much draft may cause excessive temperatures in the appliance. An uncontrollable burn or a glowing red stove part or chimney indicates excessive draft. 3. Inadequate draft may cause backpuffing into the room and plugging of the chimney. Smoke...

  • Page 6

    6 130715-24 ©pacific energy fireplace products ltd. 1. Burn cord wood only, dry and well seasoned. The denser or heavier the wood when dry, the greater its heat value. This is why hardwoods are generally preferred. Green or wet wood will cause a rapid buildup of creosote. If you feel it is necessary...

  • Page 7

    130715-24 7 ©pacific energy fireplace products ltd. Maintenance checks check the following parts for damage such as cracks, excessive corrosion, burned out sections and excessive warping: (see website for descriptions and more detail) some warping of the baffle is normal(up to 1/4” or .65cm). Replac...

  • Page 8

    8 130715-24 ©pacific energy fireplace products ltd. 37 1/4" 945 27 5/8" 701 36 1/2" 926 20 1/2" 522 18 5/8" 473 18 1/8" 459 6" 152 newcastle 1.6 dimensions crate removal 1) carefully remove wood top and supports. 2) remove plastic cover. 3) using a 7/16"(12mm) wrench, remove lag bolts that secure ho...

  • Page 9

    130715-24 9 ©pacific energy fireplace products ltd. 3) remove the screws securing the top rear piece to the rear shield and lift the piece off over the flue collar. Fig. #3 4) open the door slightly and lift the door to disengage the hinge pins from the hinge bracket. 5) while supporting the side pa...

  • Page 10

    10 130715-24 ©pacific energy fireplace products ltd. 7) remove the two screws securing the front leg cover to the leg. Fig. #5 8) repeat steps 5-7 on the opposite side of the unit. 9) remove the stop screws in the ends of the curved brackets behind the leg adapter cover. Fig. #6 10) lift and turn th...

  • Page 11

    130715-24 11 ©pacific energy fireplace products ltd. 8" [203mm] 16" [406mm] 8" [203mm] canada only ember protection the stove may be installed on a combustible floor provided ember protection made from a non-combustible material with a minimum k value of 23.7 btu/ft h ˚f is used. Equivalent to 20ga ...

  • Page 12

    12 130715-24 ©pacific energy fireplace products ltd. Warning: under no circumstances is this woodstove to be installed in a makeshift or "temporary" manner. It may be fired only after the following conditions have been met. * do not attempt to connect this woodstove to any air distribution duct. * o...

  • Page 13: Residential

    130715-24 13 ©pacific energy fireplace products ltd. Fig. #10 double wall connector - residential single wall connector - residential alcove: min. Height 7' max. Depth 3' 18" 457mm 12" 305mm 25 1/2” 673mm 20" 508mm 8" 203mm 11" 279mm 5" 127mm 15" 381mm 3" 76mm 8" 203mm 3" 76mm 8" 203mm 8" 203mm 21 1...

  • Page 14

    14 130715-24 ©pacific energy fireplace products ltd. Fig. #11 chimney roof flashing storm collar * 4" diameter air inlet with rodent screen * if the crawl space is well ventilated it is not necessary to extend air inlet to outside spark arrestor rain cap radiation shield chimney connector chimney su...

  • Page 15

    130715-24 15 ©pacific energy fireplace products ltd. Fig. #12 chimney * 4" diameter air inlet with rodent screen * if the crawl space is well ventilated it is not necessary to extend air inlet to outside concrete cap chimney connector 12"(305mm) minimum first section of pipe. Fireclay flue liner min...

  • Page 16: Mobile Home

    16 130715-24 ©pacific energy fireplace products ltd. 15" 381mm 21 1/2" 549mm 8" 203mm 11" 279mm 5" 127mm 3" 76mm 3" 76mm mobile home minimum clearance to combustibles additional requirments: warning: under no circumstances is this woodstove to be installed in a makeshift or "temporary" manner. It ma...

  • Page 17

    130715-24 17 ©pacific energy fireplace products ltd. The optional blower kit (wodc.Blow) is equipped with a three prong power cord and may be installed at any time. Follow installation instructions supplied with the kit. Route power supply cord away from woodstove. Electrical rating: 115 volts a.C.,...

  • Page 18

    18 130715-24 ©pacific energy fireplace products ltd. Troubleshooting problem cause cure glass is dirty 1. Wood is wet - use dry wood 2. Turning down air control - do not turn down until or damper too soon a) there is a good bed of coals b) the wood is charred 3. Draft too low - improper chimney heig...

  • Page 19

    130715-24 19 ©pacific energy fireplace products ltd. Replacement parts - newcastle 1.6 (when ordering, include part number with description) item description part no. Item description part no. 2............Newcastle side panel - cast .......Ca16.5037710107xxx 3............Door catch ...................

  • Page 20

    20 130715-24 ©pacific energy fireplace products ltd. Operating tips 1. Always use dry, seasoned firewood, up to 16"(406mm) long. Load wood, a mixture of large and small pieces, on top of a good ash base (1" minimum(25mm)). 2. Operate on a medium to high setting, for up to 1 hour from cold start. Aft...

  • Page 21

    130715-24 21 ©pacific energy fireplace products ltd. Item dimensions part number a 1 1/2” x 4 1/2” x 1 1/4” (39 mm x 115 mm x 32 mm) 248.0 b 3” x 4 1/2” x 1 1/4” (77 mm x 115 mm x 32 mm) 247.0 d 9” x 4 1/2” x 1 1/4” (230 mm x 115 mm x 32 mm) 5096.99 neo 1.6 firebrick installation instructions this p...

  • Page 22

    22 130715-24 ©pacific energy fireplace products ltd. Warranty information pacific energy limited lifetime warranty wood products pacific energy extends the following warranty coverage to the original registered purchaser of the product: ltd lifetime coverage (10 years) limited lifetime coverage is e...

  • Page 23: Caution

    130715-24 23 ©pacific energy fireplace products ltd. Label a. 12 in. / 305 mm 12 in. / 305 mm b. 12 in. / 305 mm  12 in./305 mm c. 8 in. / 203 mm 8 in. / 203 mm d. 22.5 in. / 572 mm 22.5 in. / 572 mm e. 15 in. / 381 mm 15 in. / 381 mm f. 17 in. / 432 mm 17 in. / 432 mm a. 8 in. / 203 mm 8 in. / ...

  • Page 24

    Pacific energy fireplace products ltd. 2975 allenby rd., duncan, b.C. V9l 6v8 for technical support, please contact your retailer. Web site: http://www.Pacificenergy.Net printed in canada.