    050515-24 neo25 - neostone 5055.875 installation and operating instructions safety notice if this stove is not properly installed, a house fi re may result. For your safety, follow the installation instructions. Contact local building or fi re officials about restrictions and installation inspection...

  • Page 2: Contents

    2 050515-24 ©pacific energy fireplace products ltd. Please save these instructions this manual describes the installation and operation of the pacifi c energy, neostone 2.5 freestanding wood heater. This heater meets the 2015 u.S. Environmental protection agency's crib wood emission limits for wood ...

  • Page 3

    050515-24 3 ©pacific energy fireplace products ltd. Chimney smoke and creosote formation when wood is burned slowly, it produces tar and other organic vapours, which combine with expelled moisture to form creosote. The creosote vapours condense in the relatively cool chimney fl ue of a slow burning ...

  • Page 4

    4 050515-24 ©pacific energy fireplace products ltd. Caution: never use gasoline, gasoline type lantern fuel, kerosene, charcoal lighter fl uid or similar liquids to start or "freshen up" a fi re in this heater. Keep all such liquids well away from the heater while it is in use. Caution: hot while in...

  • Page 5

    050515-24 5 ©pacific energy fireplace products ltd. Proper draft 1. Draft is the force which moves air from the appliance up through the chimney. The amount of draft in your chimney depends on the length of the chimney, local geography, nearby obstructions and other factors. 2. Too much draft may ca...

  • Page 6

    6 050515-24 ©pacific energy fireplace products ltd. 1. Burn cord wood only, dry and well seasoned. The denser or heavier the wood when dry, the greater its heat value. This is why hardwoods are generally preferred. Green or wet wood will cause a rapid buildup of creosote. If you feel it is necessary...

  • Page 7

    050515-24 7 ©pacific energy fireplace products ltd. Maintenance checks check the following parts for damage such as cracks, excessive corrosion, burned out sections and excessive warping: (see website for descriptions and more detail) some warping of the baffle is normal(up to 1/4” or 6mm). Replace ...

  • Page 8

    8 050515-24 ©pacific energy fireplace products ltd. 28 5/8" 728 40" 1016 41 3/8" 1051 21 7/8" 554 24" 610 24 7/8" 633 6 1/8" 157 neo 2.5 dimensions crate removal 1) carefully remove wood top and supports. 2) remove plastic cover. 3) using a 7/16"(12mm) wrench, remove lag bolts that secure hold down ...

  • Page 9

    050515-24 9 ©pacific energy fireplace products ltd. 2) while supporting the side panel, remove the four screws securing the front and rear pin brackets to the top face of the soapstone side panel. Fig. #3 3) carefully lift the soapstone side panel to disengage the pins from the hole in the bottom of...

  • Page 10

    10 050515-24 ©pacific energy fireplace products ltd. 8" [203mm] 16" [406mm] 8" [203mm] canada only ember protection the stove may be installed on a combustible fl oor provided ember protection made from a non-combustible material with a minimum k value of 23.7 btu/ft h ˚ f is used. Equivalent to 20g...

  • Page 11

    050515-24 11 ©pacific energy fireplace products ltd. Warning: under no circumstances is this heater to be installed in a makeshift or "temporary" manner. It may be fi red only after the following conditions have been met. * do not attempt to connect this heater to any air distribution duct. * do not...

  • Page 12: Residential

    12 050515-24 ©pacific energy fireplace products ltd. Fig. #7 double wall connector - residential single wall connector - residential alcove: min. Height 7' max. Depth 3' 18" 457mm 12" 305mm 26 1/2” 673mm 20 5/8" 524mm 8" 203mm 11" 279mm 5" 127mm 15 5/8" 397mm 3" 76mm 8" 203mm 3" 76mm 8" 203mm 8" 203...

  • Page 13

    050515-24 13 ©pacific energy fireplace products ltd. Fig. #8 chimney storm collar * 4"(102mm) diameter air inlet with rodent screen * if the crawl space is well ventilated it is not necessary to extend air inlet to outside spark arrestor rain cap radiation shield chimney connector 44" (1118 mm) mini...

  • Page 14

    14 050515-24 ©pacific energy fireplace products ltd. Fig. #9 chimney * 4"(102mm) diameter air inlet with rodent screen * if the crawl space is well ventilated it is not necessary to extend air inlet to outside concrete cap chimney connector 12"(305mm) minimum fi rst section of pipe. Fireclay flue li...

  • Page 15: Mobile Home

    050515-24 15 ©pacific energy fireplace products ltd. Procedure: caution: the structural integrity of the mobile home floor, wall and ceiling/roof must be maintained. - the services of a competent or certifi ed installer, (certifi ed by the wood energy technical training program (wett) - in canada, o...

  • Page 16

    16 050515-24 ©pacific energy fireplace products ltd. Optional blower the optional blower kit (wodc.Blow) is equipped with a three prong power cord and may be installed at any time. Follow installation instructions supplied with the kit. Route power supply cord away from heater. Electrical rating: 11...

  • Page 17

    050515-24 17 ©pacific energy fireplace products ltd. Troubleshooting problem cause cure glass is dirty 1. Wood is wet - use dry wood 2. Turning down air control - do not turn down until or damper too soon a) there is a good bed of coals b) the wood is charred 3. Draft too low - improper chimney heig...

  • Page 18

    18 050515-24 ©pacific energy fireplace products ltd. Replacement parts - neo 2.5 (when ordering, include part number with description) item description part no. 1............ Soapstone panel set ..................................... ???? 3............ Door catch ........................................

  • Page 19

    050515-24 19 ©pacific energy fireplace products ltd. Operating tips 1. Always use dry, seasoned fi rewood, up to 18"(457mm) long. 2. Operate on a medium to high setting, for up to 1 hour from cold start. After the initial warm up period, refuel and leave the air control on a medium setting for 5 to ...

  • Page 20

    20 050515-24 ©pacific energy fireplace products ltd. Item dimensions part number a 9” x 4 1/2” x 1 1/4” (230 mm x 115 mm x 32 mm) 5096.99 b 2 1/8” x 9” x 1 1/4” (57 mm x 230 mm x 32 mm) 7847.3 c 4 1/2" x 4 1/2” x 1 1/4” (115 mm x 115 mm x 32 mm) 7847 d 2 1/8" x 4 1/2” x 1 1/4” (57mm x 115 mm x 32 mm...

  • Page 21

    050515-24 21 ©pacific energy fireplace products ltd. Warranty information pacifi c energy limited lifetime warranty wood products pacifi c energy extends the following warranty coverage to the original registered purchaser of the product: ltd lifetime coverage (10 years) limited lifetime coverage is...

  • Page 22

    22 050515-24 ©pacific energy fireplace products ltd..

  • Page 23: Caution

    050515-24 23 ©pacific energy fireplace products ltd. Label a. 12 in. / 305 mm 12 in. / 305 mm b. 12 in. / 305 mm 12 in./305 mm c. 8 in. / 203 mm 8 in. / 203 mm d. 23.5 in. / 597 mm 23.5 in. / 597 mm e. 15 in. / 381 mm 15 in. / 381 mm f . 17 in. / 432 mm 17 in. / 432 mm a. 8 in. / 203 mm 8 in. / 203 ...

  • Page 24

    Pacific energy fireplace products ltd. 2975 allenby rd., duncan, b.C. V9l 6v8 for technical support, please contact your retailer. Web site: http://www.Pacifi cenergy.Net printed in canada.