Pacific Energy NEO 2.5 NEWCASTLE Installation And Operating Instructions Manual

Other manuals for NEO 2.5 NEWCASTLE: Installation And Operating Instructions Manual

Summary of NEO 2.5 NEWCASTLE

  • Page 1

    150715-24 neo25 - newcastle 5055.880 installation and operating instructions safety notice if this stove is not properly installed, a house fire may result. For your safety, follow the installation instructions. Contact local building or fire officials about restrictions and installation inspection ...

  • Page 2: Contents

    2 150715-24 ©pacific energy fireplace products ltd. Please save these instructions this manual describes the installation and operation of the pacific energy, newcastle 2.5 freestanding wood woodstove. This woodstove meets the 2015 u.S. Environmental protection agency's crib wood emission limits for...

  • Page 3

    150715-24 3 ©pacific energy fireplace products ltd. Chimney smoke and creosote formation when wood is burned slowly, it produces tar and other organic vapours, which combine with expelled moisture to form creosote. The creosote vapours condense in the relatively cool chimney flue of a slow burning f...

  • Page 4

    4 150715-24 ©pacific energy fireplace products ltd. Caution: never use gasoline, gasoline type lantern fuel, kerosene, charcoal lighter fluid or similar liquids to start or "freshen up" a fire in this woodstove. Keep all such liquids well away from the woodstove while it is in use. Caution: hot whil...

  • Page 5

    150715-24 5 ©pacific energy fireplace products ltd. Proper draft 1. Draft is the force which moves air from the appliance up through the chimney. The amount of draft in your chimney depends on the length of the chimney, local geography, nearby obstructions and other factors. 2. Too much draft may ca...

  • Page 6

    6 150715-24 ©pacific energy fireplace products ltd. 1. Burn cord wood only, dry and well seasoned. The denser or heavier the wood when dry, the greater its heat value. This is why hardwoods are generally preferred. Green or wet wood will cause a rapid buildup of creosote. If you feel it is necessary...

  • Page 7

    150715-24 7 ©pacific energy fireplace products ltd. Maintenance checks check the following parts for damage such as cracks, excessive corrosion, burned out sections and excessive warping: (see website for descriptions and more detail) some warping of the baffle is normal(up to 1/4” or .65cm). Replac...

  • Page 8

    8 150715-24 ©pacific energy fireplace products ltd. Neo 2.5 dimensions crate removal 1) carefully remove wood top and supports. 2) remove plastic cover. 3) using a 7/16"(12mm) wrench, remove lag bolts that secure hold down brackets to bottom pallet. 4) slide the hold down brackets away from the stov...

  • Page 9

    150715-24 9 ©pacific energy fireplace products ltd. 3) remove the screws securing the top rear piece to the rear shield and lift the piece off over the flue collar. Fig. #3 4) open the door slightly and lift the door to disengage the hinge pins from the hinge bracket. 5) while support the side panel...

  • Page 10

    10 150715-24 ©pacific energy fireplace products ltd. 7) remove the two screws securing the front leg cover to the leg. Fig. #5 8) repeat steps 5-7 on the opposite side of the unit. 9) remove the stop screws in the ends of the curved brackets behind the leg adapter cover. Fig. #6 10) lift and turn th...

  • Page 11

    150715-24 11 ©pacific energy fireplace products ltd. 8" [203mm] 16" [406mm] 8" [203mm] canada only ember protection the stove may be installed on a combustible floor provided ember protection made from a non-combustible material with a minimum k value of 23.7 btu/ft h ˚f is used. Equivalent to 20ga ...

  • Page 12

    12 150715-24 ©pacific energy fireplace products ltd. Warning: under no circumstances is this woodstove to be installed in a makeshift or "temporary" manner. It may be fired only after the following conditions have been met. * do not attempt to connect this woodstove to any air distribution duct. * o...

  • Page 13: Residential

    150715-24 13 ©pacific energy fireplace products ltd. Fig. #10 double wall connector - residential single wall connector - residential alcove: min. Height 7' max. Depth 3' 18" 457mm 12" 305mm 26 1/2” 673mm 20 5/8" 524mm 8" 203mm 11" 279mm 5" 127mm 15 5/8" 397mm 3" 76mm 8" 203mm 3" 76mm 8" 203mm 8" 20...

  • Page 14

    14 150715-24 ©pacific energy fireplace products ltd. Fig. #11 chimney storm collar * 4"(102mm) diameter air inlet with rodent screen * if the crawl space is well ventilated it is not necessary to extend air inlet to outside spark arrestor rain cap radiation shield chimney connector 44 3/8" (1127mm) ...

  • Page 15

    150715-24 15 ©pacific energy fireplace products ltd. Fig. #12 chimney * 4"(102mm) diameter air inlet with rodent screen * if the crawl space is well ventilated it is not necessary to extend air inlet to outside concrete cap chimney connector 12"(305mm) minimum first section of pipe. Fireclay flue li...

  • Page 16: Mobile Home

    16 150715-24 ©pacific energy fireplace products ltd. 15 5/8" 397mm 22 1/2" 572mm 8" 203mm 11" 279mm 5" 127mm 3" 76mm 3" 76mm mobile home minimum clearance to combustibles additional requirments: warning: under no circumstances is this woodstove to be installed in a makeshift or "temporary" manner. I...

  • Page 17

    150715-24 17 ©pacific energy fireplace products ltd. Optional blower the optional blower kit (wodc.Blow) is equipped with a three prong power cord and may be installed at any time. Follow installation instructions supplied with the kit. Route power supply cord away from woodstove. Electrical rating:...

  • Page 18

    18 150715-24 ©pacific energy fireplace products ltd. Troubleshooting problem cause cure glass is dirty 1. Wood is wet - use dry wood 2. Turning down air control - do not turn down until or damper too soon a) there is a good bed of coals b) the wood is charred 3. Draft too low - improper chimney heig...

  • Page 19

    150715-24 19 ©pacific energy fireplace products ltd. 16 ..........Air shutter assembly ......................................Ne16.7826 17 ..........Secondary air control assembly ..................... Ne16.7838 18 ..........Newcastle top assy. - cast .................Ca25.Tgassyxxx 19 ..........Leve...

  • Page 20

    20 150715-24 ©pacific energy fireplace products ltd. Operating tips 1. Always use dry, seasoned firewood, up to 18"(457mm) long. 2. Operate on a medium to high setting, for up to 1 hour from cold start. After the initial warm up period, refuel and leave the air control on a medium setting for 5 to 1...

  • Page 21

    150715-24 21 ©pacific energy fireplace products ltd. Item dimensions part number a 9” x 4 1/2” x 1 1/4” (230 mm x 115 mm x 32 mm) 5096.99 b 2 1/8” x 9” x 1 1/4” (57 mm x 230 mm x 32 mm) 7847.3 c 4 1/2" x 4 1/2” x 1 1/4” (115 mm x 115 mm x 32 mm) 7847 d 2 1/8" x 4 1/2” x 1 1/4” (57mm x 115 mm x 32 mm...

  • Page 22

    22 150715-24 ©pacific energy fireplace products ltd. Warranty information pacific energy limited lifetime warranty wood products pacific energy extends the following warranty coverage to the original registered purchaser of the product: ltd lifetime coverage (10 years) limited lifetime coverage is e...

  • Page 23: Caution

    150715-24 23 ©pacific energy fireplace products ltd. Label a. 12 in. / 305 mm 12 in. / 305 mm b. 12 in. / 305 mm 12 in./305 mm c. 8 in. / 203 mm 8 in. / 203 mm d. 23.5 in. / 597 mm 23.5 in. / 597 mm e. 15 in. / 381 mm 15 in. / 381 mm f. 17 in. / 432 mm 17 in. / 432 mm a. 8 in. / 203 mm 8 in. / 20...

  • Page 24

    Pacific energy fireplace products ltd. 2975 allenby rd., duncan, b.C. V9l 6v8 for technical support, please contact your retailer. Web site: http://www.Pacificenergy.Net printed in canada.