Pacific Energy PACIFIC VISTA INSERT Installation And Operating Instructions Manual

Summary of PACIFIC VISTA INSERT

  • Page 1

    210513-24 vista insert-d 5055.3231 installation and operating instructions model: pacific vista insert series: d safety notice if this stove is not properly installed, a house fi re may result. For your safety, follow the installation instructions. Contact local building or fi re officials about res...

  • Page 2: Contents

    2 vista insert-d 210513-24 contents safety ............................................................................................ 3 dimensions ............................................................................................ 3 clearances ................................................

  • Page 3: Dimensions

    210513-24 vista insert-d 3 ರ 15” clearances masonry or factory built fireplace the minimum required clearances to surrounding combustible materials when installed into a masonry or factory built fi replace are listed below and in fig. #1. Minimum clearances to combustibles (measured from insert body...

  • Page 4

    4 vista insert-d 210513-24 maintenance checks check the following parts for damage such as cracks, excessive corrosion, burned out sections and excessive warping: (see website for descriptions and more detail) weekly: - firebrick - visual, for cracking. - door gasket - sagging, placement, damage. Mo...

  • Page 5

    210513-24 vista insert-d 5 16” non-combustible fi replace hearth 23 1/2” 19 7/8” 18” 8” 8” fireplace hearth requirements: (measured without the insert) the hearth may be fl ush with or raised above an adjacent combustible fl oor and must extend 16” in front and 8” beyond each side of the fi replace ...

  • Page 6

    6 vista insert-d 210513-24 installation your insert is designed to be installed into a masonry or fac- tory built zero-clearance fi replace. The masonry fi replace must be built according to the requirements of the standard of chimneys, fireplaces, vents and solid fuel burning ap- pliances, n.F.P.A....

  • Page 7

    210513-24 vista insert-d 7 full flue liner -(required in canada) 1) measure the chimney height from the top of the existing fl ue to the fl oor of the hearth. This will allow extra length of liner for fl ashing and rain cap. 2) feed the stainless steel liner from top of the chimney, through the damp...

  • Page 8

    8 vista insert-d 210513-24 surround assembly and installation 1) lay part a, b and c face down on a fl at non-marring surface. Fasten together with 1/4" x 1/2" bolts and nuts provided through holes at points “d” (fig. #8 and 9). 2) lift the surround assembly to the upright position and make sure the...

  • Page 9

    210513-24 vista insert-d 9 blower the insert comes equipped with a variable speed circulating air blower. The blower system is thermostatically controlled for automatic operation, as well manually with a convenient bypass switch. Blower operation automatic: to operate the blower automatically, push ...

  • Page 10

    10 vista insert-d 210513-24 operation wood selection this heater is designed to burn natural wood only. Higher efficiency and lower emissions generally result when burning air-dried seasoned hardwoods, as compared to softwoods or too green or freshly cut hardwoods. Wood should be properly air dried ...

  • Page 11

    210513-24 vista insert-d 11 in summary, a certain amount of creosote is inevitable and must be lived with. Regular inspection and cleaning is the solution. The use of dry, seasoned wood and ample combus- tion air will help to minimize the buildup. Chimney fires the result of excessive creosote build...

  • Page 12

    12 vista insert-d 210513-24 remove all particles of glass. Be careful as they are very sharp. Install new glass complete with gasket. Replace frame and screws. Warning: do not overtighten, tighten screws very carefully. - do not clean glass when hot - do not use abrasive cleaners on glass 6. Do not ...

  • Page 13

    210513-24 vista insert-d 13 appendix a troubleshooting problem cause cure excessive creosote 1) wood is too wet - use dry wood buildup 2) turning down air control - do not turn down until: too soon a) there is a good bed of coals b) the wood is charred 3) draft too low - improper chimney height and/...

  • Page 14: Pacifi C Vista Insert

    14 vista insert-d 210513-24 pacifi c vista insert firebrick installation instructions this package contains 12 full-size fi rebricks. With the heater in the upright position, install fi rebricks as follows: - first, install 4 fi rebricks against the rear wall. - next, install the side fi rebricks, 2...

  • Page 15: Replacement Parts

    210513-24 vista insert-d 15 28 26 27 25 27 22 20 19 11 18 16 15a 14 17 22 14 13 12a 13 2 3 1 4 5 10 6 7 15b 8 9 12b 22 2......Air control cover ............................................................... 2327 3......Blower bracket ....................................................................

  • Page 16: Replacement Parts - Blower

    16 vista insert-d 210513-24 replacement parts - blower item description part no. Item description part no. 1.....Ash lip/blower housing ................................. Vinc.2310 1a...Ashlip ........................................................................2369 2.....Blower only ................

  • Page 17: Pacifi C Vista Insert

    210513-24 vista insert-d 17 installation: unpack and inspect the hear th trim. Install the surround assembly as per instruction supplied with the appliance. Attach hearth trim to the bottom of the surround with clips provided. The clips are installed up through the this kit contains: 1.......Hearth ...

  • Page 18

    18 vista insert-d 210513-24.

  • Page 19: Made In Canada

    210513-24 vista insert-d 19 label minimum clearance to combustibles (measured from insert body) dÉgagement minimum aux combustibles a) adjacent sidewall/ 229 mm / 9 in paroi latÉrale adjacente b) mantel 381 mm / 15in c) top facing/ 381 mm / 15 in revÊtement supÉrieur d) side facing/ 229 mm / 9 in re...

  • Page 20

    Pacific energy fireplace products ltd. Phone: 1-250-748-1184 web site: http://www.Pacifi cenergy.Net 2975 allenby rd., duncan, b.C. V9l 6v8 pacific energy fireplace products ltd. Phone: 1-250-748-1184 web site: http://www.Pacifi cenergy.Net 2975 allenby rd., duncan, b.C. V9l 6v8 printed in canada.