    Warning: if the information in these instructions is not followed exactly, a fi re or explosion may result causing property damage, personal injury or death. This appliance may be installed in an aftermarket permanently located, manufactured home (usa only) or mobile home, where not prohibited by lo...

  • Page 2: Danger

    2 5055.45-a 261015-44 trnt.Bodya hot glass will cause burns. Do not touch glass until cooled. Never allow children to touch glass. ! Danger a barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appliance and shall be installed for the protection of children a...

  • Page 3

    3 trnt.Bodya 5055.45-a 261015-44 important note for the commonwealth of massachusetts: from massachusetts rules and regulations 248 cmr 5.08: (a) for all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential pur...

  • Page 4: Caution

    4 5055.45-a 021115-40 trnt.Bodya owner information congratulations on your purchase of a pacific energy gas stove. Your trenton direct vent, free-standing gas stove has been professionally installed by: dealer name: ___________________________________ phone number: _________________________________ ...

  • Page 5: First Fire

    5 trnt.Bodya 5055.45-a 021115-40 owner information when lit for the first time, the gas stove will emit a slight odor for a couple of hours. This is due to the curing of paints, sealants, gaskets, and lubricants used in the manufacturing process. This condition is temporary. Open doors and windows t...

  • Page 6: Manufactured (Mobile) Homes

    6 5055.45-a 021115-40 trnt.Bodya owner information manufactured (mobile) homes in some jurisdictions, the trenton gas stove may be installed in manufactured homes after the “first sale”. Consult local codes for approval. The gas stove must be fastened in place. Install in accordance with the current...

  • Page 7: Remote Control System

    7 trnt.Bodya 5055.45-a 021115-40 owner information the profl ame remote control system consists of three elements: 1. Profl ame remote transmitter. 2. Profl ame integrated fireplace control (ifc) module. 3. A wiring harness to connect the ifc to the gas valve and stepper motor. Blue back lit lcd dis...

  • Page 8

    8 5055.45-a 021115-40 trnt.Bodya owner information temperature indication display with the remote transmitter in the “off” position, press the thermostat key and the mode key at the same time. Look at the lcd screen on the remote transmitter to verify that a c or f is visible to the right of the roo...

  • Page 9

    9 trnt.Bodya 5055.45-a 021115-40 owner information remote flame control the proflame has six (6) flame levels. With the system turned on, and the flame level at maximum in the gas stove, press the down arrow key once to reduce the flame height by one step until the flame is turned off. The up arrow ...

  • Page 10

    10 5055.45-a 021115-40 trnt.Bodya owner information comfort fan speed control if the gas stove is equipped with a hot air circulating fan, the speed of the fan can be controlled by the profl ame system. The fan speed can be adjusted through six (6) speeds. To activate this function use the mode key ...

  • Page 11: Warnings and Cautions

    11 trnt.Bodya 5055.45-a 021115-40 owner information low battery power detection remote transmitter the life span of the remote control batteries depends on various factors: quality of the batteries used, the number of ignitions of the gas stove, the number of changes to the room thermostat set point...

  • Page 12: Maintenance

    12 5055.45-a 021115-40 trnt.Bodya owner information turn off gas and electrical power supply (if applicable) and allow ample time for the gas stove to cool before servicing gas stove. It is recommended that the gas stove and its venting should be inspected at least once a year by a qualified service...

  • Page 13: Lighting Instructions

    13 trnt.Bodya 5055.45-a 021115-40 owner information for your safety read before lighting lighting instructions to turn off gas appliance warning: if you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This applianc...

  • Page 14: Trenton Gas Stove Dimensions

    14 5055.45-a 021115-40 trnt.Bodya installer information 26 3/4” 30 5/8” 21 15/16” 24” trenton gas stove dimensions dimensions height 30 5/8 inches width 26 3/4 inches depth 21 15/16 inches height to center of flue outlet 24 inches figure 21: trenton dimensions..

  • Page 15: Clearances to Combustibles

    15 trnt.Bodya 5055.45-a 021115-40 installer information clearances to combustibles minimum clearance to combustible materials interior side wall 4” interior back wall 4 “ interior ceiling 18” venting pipe clearance 1” 4” 4” 1” 4” 4” 4” 1” 4” vertical venting horizontal venting vertical venting verti...

  • Page 16: Vent Terminal Clearances

    16 5055.45-a 021115-40 trnt.Bodya installer information m k i a v g g h a j v g a b c a v v a v b f b l v e v v v d a= *12 inches (30 cm) min. Clearances above grade, veranda, porch, deck, or balcony b= *12 inches (30 cm) min. Clearance to window or door that may be opened c= 12 inches (30 cm) min. ...

  • Page 17

    17 trnt.Bodya 5055.45-a 021115-40 installer information trenton co-axial venting chart 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 venting horizontal run ve nt ing ve rt ic al ri se no venting option venting envelope no venting op...

  • Page 18: Co-Linear Venting

    18 5055.45-a 021115-40 trnt.Bodya installer information co-linear venting intake air exhaust air co-linear venting notes: • tn24 requires a 3 inch diameter exhaust vent and a 3 inch intake vent. • max. Vent height 35’ (15.25m) to termination • min. Vent height 10’ (3m) to termination. High wind cap ...

  • Page 19: Venting Components

    19 trnt.Bodya 5055.45-a 021115-40 installer information venting components description icc exceldirect® metal-fab® sure-seal security secure vent™ selkirk direct-temp™ duravent directvent pro® galvanize d black galvanized black galvanized black galvanized black galvanized black 6” pipe length 4dl6 4...

  • Page 20

    20 5055.45-a 021115-40 trnt.Bodya installer information left blower fan ifc module right blower fan battery bay electrical connection gas connection gas valve trenton gas stove rear component this gas stove is certified for use with 4” x 6⅝”coaxial venting components only. It is permitted to only us...

  • Page 21: Gas Connection

    21 trnt.Bodya 5055.45-a 021115-40 installer information gas connection to make the required electrical and gas connections, start by positioning the gas stove. Connect the gas supply line (not included) to the ⅜” fl are fi tting at the rear of the unit as seen in (figure 32). Please see the gas supp...

  • Page 22: Packaging

    22 5055.45-a 021115-40 trnt.Bodya installer information packaging the trenton gas stove comes with the ceramic panels and gas burner already installed. The log set and glowing embers are packaged in protective styrofoam and secured in place by the glass door and screen. The glass door and screen mus...

  • Page 23: Log Set Pieces

    23 trnt.Bodya 5055.45-a 021115-40 installer information 1. Remove the mesh screen as described on page 22. 2. Remove the wing nut bolts (figure 37) securring the glass door retainer frame to the gas stove frame and tilt the glass door so that it can be removed (figure 38). 3. Remove the glass door t...

  • Page 24: Installation Of Log Set

    24 5055.45-a 021115-40 trnt.Bodya installer information installation of log set 1. Fill burner basket (figure 42) with embers so that the baskets are filled and overflowing the burners’ front row (figure 43). Reserve a small amount of embers for final placement. 2. Place first log onto the ledge in ...

  • Page 25

    25 trnt.Bodya 5055.45-a 021115-40 installer information 5. Place 4th log as shown in (figure 47). The black charcoal side of the piece must face inwards. This log will act as a support for the final log. 6. Place 5th log as shown in (figure 48) making sure that the log does not cover the holes of th...

  • Page 26: Glass Door Installation

    26 5055.45-a 021115-40 trnt.Bodya installer information (figure 49) shows the burners’ back row as not being covered by the logs. At this time, the small amount of embers reserved at the beginning of log placement can be used to fill any left over spaces. Note: although it is permisable to place a f...

  • Page 27: Screen Mesh Installation

    27 trnt.Bodya 5055.45-a 021115-40 installer information screen mesh installation the screen mesh is positioned between the glass door and the doors. It's purpose is to provide protection from the heat radiating from the glass door. The screen has a front side and a rear side and must be oriented cor...

  • Page 28

    28 5055.45-a 021115-40 trnt.Bodya installer information the bottom edge of the screen mesh must fi t fi rmly into the channel provided for it in the fi re box frame. (figure 57) shows the location of the screen mesh channel. Fire box side door side the screen mesh top holder (figure 58) positions th...

  • Page 29: Accent Lighting Glass Plates

    29 trnt.Bodya 5055.45-a 021115-40 installer information the trenton gas stove comes with an assortment of glass plates of various colours. Accent lighting is controlled via the remote control transmitter included with the trenton gas stove (figure 1 on page 7). The glass plate tray is located undern...

  • Page 30: Operating Procedure

    30 5055.45-a 021115-40 trnt.Bodya installer information 1. Install 4 aa batteries into the trenton battery holder (figure 62) located on the rear side of the trenton. Make sure that the selection switch on the switch cover is on the “remote” setting. 2. Install 3 aaa batteries into the profl ame2 re...

  • Page 31: Venturi Adjustment

    31 trnt.Bodya 5055.45-a 021115-40 installer information venturi adjustment adjustment loosen wing nut and move post up to open venturi, and down to close venturi. Tighten wing-nut once adjustment is complete. Note: venturi should be closed when using natural gas and open when using liquid propane. V...

  • Page 32: Gas Pressure Requirements

    32 5055.45-a 021115-40 trnt.Bodya installer information servicing of the gas stove can be performed from the rear of the unit by removing the access panel from the unit. Caution: the gas line should be installed by a qualified service person in accordance with all building codes. This section is int...

  • Page 33: Pilot Flame Adjustment

    33 trnt.Bodya 5055.45-a 021115-40 installer information note: to test the gas pressure, turn off the gas supply to the gas stove before loosening test point screws. Verify gas pressures with the gas stove lit and at the highest setting. 1. Remove back panel and locate the valve as seen in (figure 69...

  • Page 34: Propane Conversion

    34 5055.45-a 021115-40 trnt.Bodya installer information before starting the conversion make sure to shut off the gas supply to the unit and allow gas stove to cool to room temperature. To convert the gas stove from natural gas to propane the (trnt.Lpkita) kit is required. This kit comes with new pil...

  • Page 35: Replacement Parts

    35 trnt.Bodya 5055.45-a 021115-40 installer information replacement parts trenton sales codes description sales code trenton unit complete trnt.Bodya optional trenton lp conversion kit trnt.Lpkita replacement trenton door with glass trnt.Doora trenton screen trnt.Scrna trenton control tray complete ...

  • Page 36: Wiring Diagram

    36 5055.45-a 021115-40 trnt.Bodya installer information wiring diagram caution: label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Lamp comfort fan pilot burner.

  • Page 37: Rating Label

    37 trnt.Bodya 5055.45-a 021115-40 installer information rating label the rating label - as shown - is located on the rear of the gas stove..

  • Page 38

    38 5055.45-a 021115-40 trnt.Bodya installer information.

  • Page 39

    39 trnt.Bodya 5055.45-a 021115-40 installer information.

  • Page 40

    © 2015 copyright pacific energy fireplace products ltd reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws. For technical support, please contact your retailer web site: www. Pacificenergy.Net 2975 allenby rd., duncan, b...