Pacific Energy VISTA D SERIES Installation And Operating Instructions Manual

Summary of VISTA D SERIES

  • Page 1

    200516-20 vista insert-d 5055.3231 installation and operating instructions model: pacific vista insert series: d safety notice if this stove is not properly installed, a house fi re may result. For your safety, follow the installation instructions. Contact local building or fi re officials about res...

  • Page 2: Contents

    2 vista insert-d 200516-20 contents safety ............................................................................................ 3 dimensions ............................................................................................ 3 clearances ................................................

  • Page 3: Dimensions

    34 3/4” 883mm 15” 381mm 9” 229mm 9” 229mm 8” 203mm 16” 406mm clearances masonry or factory built fireplace the minimum required clearances to surrounding combustible replace are listed below and in fig. #1. Minimum clearances to combustibles (measured from insert body) adjacent sidewall ...............

  • Page 4

    Maintenance checks check the following parts for damage such as cracks, excessive corrosion, burned out sections and excessive warping: (see website for descriptions and more detail) weekly: - firebrick - visual, for cracking. - door gasket - sagging, placement, damage. Monthly - brick rail tabs and...

  • Page 5

    200516-20 vista insert-d 5 16” 406mm non-combustible fi replace hearth 24” 610mm 20” 508mm 15” 381mm 8” 203mm fireplace hearth requirements: (measured without the insert) the hearth may be fl ush with or raised above an adjacent combustible fl oor and must extend 16”(406mm) in front and 8”(203mm) be...

  • Page 6

    Installation your insert is designed to be installed into a masonry or fac- tory built zero-clearance fi replace. The masonry fi replace must be built according to the requirements of the standard of chimneys, fireplaces, vents and solid fuel burning appliances, n.F.P.A. 211 (latest edition) or appl...

  • Page 7

    Full flue liner -(required in canada) 1) measure the chimney height from the top of the existing fl ue to the fl oor of the hearth. This will allow extra length of liner for fl ashing and rain cap. 2) feed the stainless steel liner from top of the chimney, through the damper area and into the fi rep...

  • Page 8

    Surround assembly and installation 1) lay part a, b and c face down on a fl at non-marring surface. Fasten together with 1/4" x 1/2" bolts and nuts provided through holes at points “d” (fig. #8 and 9). 2) lift the surround assembly to the upright position and make sure the front face is fl at and ev...

  • Page 9

    Blower the insert comes equipped with a variable speed circulating air blower. The blower system is thermostatically controlled for automatic operation, as well manually with a convenient bypass switch. Blower operation automatic: to operate the blower automatically, push the rocker switch to the “0...

  • Page 10

    Operation wood selection this heater is designed to burn natural wood only. Higher efficiency and lower emissions generally result when burning air-dried seasoned hardwoods, as compared to softwoods or too green or freshly cut hardwoods. Wood should be properly air dried (seasoned) for six months or...

  • Page 11

    1. Highest smoke densities and emissions occur when a large amount of wood is added to a bed of hot coals and the air inlet is closed. The heated wood generates smoke, but without ample air, the smoke cannot burn. Smoke- free, clean burning requires small fuel loads, two or three logs at a time or 1...

  • Page 12

    To remove broken glass, undo the four retaining screws and remove the frame noting position for re-assembly. Remove all particles of glass. Be careful as they are very sharp. Install new glass complete with gasket. Replace frame and screws. Warning: do not overtighten, tighten screws very carefully....

  • Page 13

    Appendix a troubleshooting problem cause cure excessive creosote 1) wood is too wet - use dry wood buildup 2) turning down air control - do not turn down until: too soon a) there is a good bed of coals b) the wood is charred 3) draft too low - improper chimney height and/or diameter - chimney plugge...

  • Page 14: Pacifi C Vista Insert

    Pacifi c vista insert firebrick installation instructions this package contains 12 full-size fi rebricks. With the heater in the upright position, install fi rebricks as follows: - first, install 4 fi rebricks against the rear wall. - next, install the side fi rebricks, 2 each side. - lastly, place ...

  • Page 15: Replacement Parts

    26 27 25 22 20 19 11 18 16 15a 14 17 22 14 13 12a 13 2 3 1 4 5 10 6 7 15b 8 9 12b 22 2......Air control cover ............................................................... 2327 3......Blower bracket ................................................................... 2343 4......Glass clamp kit (c/...

  • Page 16: Replacement Parts - Blower

    Replacement parts - blower item description part no. Item description part no. 1.....Ash lip/blower housing ................................. Vinc.2310 1a...Ashlip ........................................................................2369 2.....Blower only ............................................

  • Page 17: Pacifi C Vista Insert

    Installation: unpack and inspect the hear th tr im. Install the surround assembly as per instruction supplied with the appliance. Attach hearth trim to the bottom of the surround with clips provided. The clips are installed up through the trim and into the surround. This kit contains: 1.......Hearth...

  • Page 18

    Warranty information pacifi c energy limited lifetime warranty wood products pacifi c energy extends the following warranty coverage to the original registered purchaser of the product: ltd lifetime coverage (10 years) limited lifetime coverage is extended to the following components (parts only) po...

  • Page 19: Made In Canada

    Label minimum clearance to combustibles (measured from insert body) dÉgagement minimum aux combustibles a) adjacent sidewall/ 229 mm / 9 in paroi latÉrale adjacente b) mantel 381 mm / 15in c) top facing/ 381 mm / 15 in revÊtement supÉrieur d) side facing/ 229 mm / 9 in revÊtement latÉral e) firing s...

  • Page 20

    Pacific energy fireplace products ltd. Phone: 1-250-748-1184 web site: http://www.Pacifi cenergy.Net 2975 allenby rd., duncan, b.C. V9l 6v8 pacific energy fireplace products ltd. Phone: 1-250-748-1184 web site: http://www.Pacifi cenergy.Net 2975 allenby rd., duncan, b.C. V9l 6v8 printed in canada.