    161009-24 spnd.Bodya 5055.101.C model: super insert design-d safety notice if this stove is not properly installed, a house fire may result. For your safety, follow the installation directions. Consult local building inspector or officials about restrictions and installation inspection requirements ...

  • Page 2

    2 spnd.Bodya 161009-24 contents safety.......................................................................................................................3 clearances ..............................................................................................................3 masonry or factory...

  • Page 3

    6.5" 30" 20.5" 2" 16" 21" with mantle shield 3 spnd.Bodya 161009-24 safety read all instructions before installing and using this appliance. We strongly recommend that smoke detectors be installed. If smoke detectors have been previously installed, you may notice that they are operating more frequen...

  • Page 4

    4 spnd.Bodya 161009-24 16” non-combustible fireplace hearth 24” 21” 18” 8” 8” fireplace hearth requirements:(measured without the insert) the non- combustible fireplace hearth must be raised 2” above an adjacent combustible floor and extend 16” in front and 8” beyond each side of the existing firepl...

  • Page 5

    5 spnd.Bodya 161009-24 42 5/8” 6 1/2” 28 7/8” 23 3/4” 21 1/2” 21 1/8” 36” 8 1/8” 20 3/4” 18” 28 1/8” 9 1/2” 10” 19 9/16” dimensions.

  • Page 6

    6 spnd.Bodya 161009-24 installation your insert is designed to be installed into a masonry or factory built zero-clearance fireplace. The masonry fireplace must be built according to the requirements of the standard of chimneys, fireplaces, vents and solid fuel burning appliances, n.F.P.A. 211 (late...

  • Page 7

    7 spnd.Bodya 161009-24 full flue liner - (required in canada) this fireplace insert must be installed with a continuous liner of 6” diameter extending from the fireplace insert to the top of the chimney. The chimney liner must conform to the class 3 requirements of can/ulc-s635, standard for lining ...

  • Page 8: Fan Speed Controller

    8 spnd.Bodya 161009-24 4) loosen the two bolts that secure the ash lip to the firebox, carefully lift up the ash lip and remove from the firebox. 5) remove the two screws securing the speed controls assembly to the ash lip. The cover plate on the opposite side can also be removed at this time 6) rem...

  • Page 9

    9 spnd.Bodya 161009-24 7) route cable from speed control to fan under the clips on the underside of the ash lip. Note wire positions.(fig.13 & fig.14) 8) remove thermal switch from right hand fan mounting bracket and secure to left hand fan mounting bracket. 9) reconnect the wires to the fans (fig.1...

  • Page 10: Surround Assembly and

    10 spnd.Bodya 161009-24 surround assembly and installation 1) lay part a, b and c face down on a flat non-marring surface. Fasten together with 1/4" x 1/2" bolts and nuts provided through holes at points “d” (fig. #19 and 22). 2) lift the surround assembly to the upright position and make sure the f...

  • Page 11

    S u r r o u n d s e c u r i n g f l a n g e screws screws tab surround screw at top of slot securing flange screw at bottom of slot. 11 spnd.Bodya 161009-24 10) once the surround is fastened to the insert, in order to maximize heated air discharge efficiency, the surround can be pulled upward so tha...

  • Page 12: Combustion Air

    12 spnd.Bodya 161009-24 combustion air consult local building codes regarding combustion air supply. Intake or combustion air can be supplied to the insert in one of two ways: 1) outside air (o/a) supply: remove cover from ash clean out in existing fireplace. Place a rodent screen in place of the co...

  • Page 13

    13 spnd.Bodya 161009-24 operation wood selection this heater is designed to burn natural wood only. Higher efficiency and lower emissions generally result when burning air-dried seasoned hardwoods, as compared to softwoods or too green or freshly cut hardwoods. Wood should be properly air dried (sea...

  • Page 14

    14 spnd.Bodya 161009-24 dispersed, they should be retained in the closed container until all cinders have thoroughly cooled. Other waste should not be placed in this container! Creosote formation and need for removal when wood is burned slowly, it produces tar and other organic vapours, which combin...

  • Page 15

    15 spnd.Bodya 161009-24 blower the super insert comes equipped with twin variable speed circulating air blowers. The blower system is thermostatically controlled for automatic operation, as well manually with a convenient bypass switch. Blower operation automatic: to operate the blowers automaticall...

  • Page 16

    16 spnd.Bodya 161009-24 maintenance 1. Burn wood only, dry and well seasoned. The denser or heavier the wood when dry, the greater its heat value. This is why hardwoods are generally preferred. Green or wet wood will cause a rapid buildup of creosote. If you feel it is necessary to burn wet or unsea...

  • Page 17

    Part revision 1 17 spnd.Bodya 161009-24 fig. # 33 2............Surround trim, black(* std.-size) .......Wind.45192 3............Front panel, left .................................. Spnd.4543 4............Bay top ............................................... Spnd.4542 5............Casing top .........

  • Page 18

    18 spnd.Bodya 161009-24 understanding & operating your pacific energy stove the pacific energy line of woodstoves is a culmination of years of research and development. Designed to be efficient, clean-burning and user-friendly, this heater will give you years of warm service. However, a knowledgeabl...

  • Page 19

    19 spnd.Bodya 161009-24 19 troubleshooting problem cause cure excessive creosote 1) wood is too wet - use dry wood buildup 2) turning down air control - do not turn down until: too soon a) there is a good bed of coals b) the wood is charred 3) draft too low - improper chimney height and/or diameter ...

  • Page 20

    20 spnd.Bodya 161009-24 notes:.

  • Page 21

    21 spnd.Bodya 161009-24 notes:.

  • Page 22

    22 spnd.Bodya 161009-24 notes:.

  • Page 23: Caution

    23 spnd.Bodya 161009-24 label minimum clearance to combustibles (measured from insert body) a) adjacent sidewall 520 mm / 20.5 in b) mantel 762 mm / 30 in mantel with shield 533 mm/ 21 in c) top facing 610 mm / 24 in d) side facing 165 mm / 6.5 in install and use only in accordance with the manufact...

  • Page 24

    Spnd.Bodya 161009-24 pacific energy fireplace products ltd. Www.Pacificenergy.Net technical support: 1-250-748-1184 2975 allenby rd., duncan, b.C. V9l 6v8 printed in canada.