ROBATA 72/54 CONCRETE FIRE CE Match-lit | Installation & Owner’s Manual
SPECIFICATIONS & CLEARANCES
1829
mm
203
mm
ROBATA 54
NATURAL GAS
ROBATA 54
PROPANE
ROBATA 72
NATURAL GAS
ROBATA 72
PROPANE
Burner Model #
LIN-E-36
LIN-E-36P
LIN-E-48
LIN-E-48P
Heat Input
G20, 20 mbar
20 kW
G31, 37 mbar
18 kW, 1210 gr/h
G20, 20 mbar
27 kW
G31, 37 mbar
25 kW, 1758 gr/h
Burner Pressure
8.7 mbar
25 mbar
8.7 mbar
25 mbar
Orifice Size
26
43
18
37
Burner Ports
35
35
47
47
Port Size
1/8" (~3 mm)
1/8" (~3 mm)
1/8" (~3 mm)
1/8" (~3 mm)
MINIMUM CLEARANCES TO COMBUSTIBLES
1829
mm
203
mm