Palsonic AOS Owner's Manual - Installation Instructions
13
Installation instructions
Use drops from here
Hook the line here
Mounting plate
Dropping line
holes for fixing
Wall hole sleeve
(hard polythene tube
prepared by user)
5mm
(tilt downward)
3
Note: When installing the pipe as per the directions
1, 2 or 4, saw the corresponding unloading piece
off the indoor unit base.
Piping direction
4
Indoor unit installation
1. Installing the Mounting Plate
Decide an installing location for the mounting plate according to the indoor unit location and piping direction.
Keep the mounting plate horizontally with a horizontal ruler or dropping line.
Drill holes of 32mm in depth on the wall for fixing the plate.
Insert the plastic plugs to the hole, fix the mounting plate with tapping screws.
Inspect if the mounting plate is well fixed. Then drill a hole for piping.
Note: The shape of your mounting plate may be different from the one above, but the installation method is similar.
2. Drill a Hole for Piping
Decide the position of hole for piping according to the
location of the mounting plate.
Drill a hole on the wall. The hole should tilt a little
downward toward outside.
Install a sleeve through the wall hole to keep the wall
tidy and clean.
3. Indoor Unit Piping Installation
Put the piping (liquid and gas pipe) and cables through the wall hole from the outside or put them through
from the inside after indoor piping and cables connection complete so as to connect to outdoor unit.
Decide whether to cut the unloading piece off in accordance with the piping direction. (as shown below)
After connecting piping as required, install the drain hose. then connect the power cords. After connecting,
wrap the piping, cords and drain hose together with thermal insulation materials.
1
2
Saw the unloading piece
off along the trough
trough
Uploading
piece
IN
D
O
O
R
O
U
T
D
O
O
R