Panamax M5510-PRO Owner's Manual - Feature Details
The MAX 5510-Pro requires line voltage to return to
within the safe operating range for 10 seconds before
returning to normal operating mode. This is referred
to as "Over/Under Voltage Recovery". The safe oper-
ating range is considered 5V above the under-voltage
threshold and 5V below the over voltage threshold.
Once this safe operating range is reached, the MAX
5510-Pro will perform the following functions:
1. Unsafe Voltage LED will flash 4 times per sec-
ond for Over/Under voltage Recovery.
2. Power is restored to all connected equipment
after the 10-second delay.
FEATURE DETAILS
(continued)
TECHNICAL SPECIFICATIONS
USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901
9
Clamping Level..............................................................................................260V
Capacitance......................................................................................30pf (approx.)
Suppression Modes...........................................................Metallic & Longitudinal
Wires Protected....................................................................2 wire/ 1 pr. (pins 4,5)
Fuseless/Auto-Resetting..................................................................................YES
Connections............................................................................................RJ-11/45
Clamping Level................................................................................................27V
Attenuation...............................................................<1 dB from 950MHz - 2.2GHz
Shielded...........................................................................................................YES
Connections......................................................................Gold plated, Female “F”
Clamping Level...............................................................................................1.4V
Attenuation.............................................................................<1 dB up to 950MHz
Shielded...........................................................................................................YES
Connections......................................................................Gold plated, Female “F”
GENERAL
SATELLITE CIRCUIT
Connection.......................................................................3.5 mm mono mini-plug
Voltage and Polarity...........................................3-18VDC nominal, bi-directional
Current Requirement....................................................................................>25mA
DC TRIGGER INPUT
Connection.......................................................................3.5 mm mono mini-plug
Voltage and Polarity...............................................................12V DC, + Center Pin
Current .......................................................................................................350mA
DC TRIGGER OUTPUT
ANT/CATV CIRCUIT
TELEPHONE CIRCUIT
LAN CIRCUIT
Initial Clamping Level.....................................................................................200V
UL 1449 Surge Suppression Rating................................................................330V
Protection Modes....................................................................... L - N, L - G, N - G
Line Voltage...............................................................................................120VAC
Max Current Rating.....................................................................15A (1800 Watts)
Response Time...............................................................................................<1ns
Joule Rating........................................................................................2325 Joules
Peak Impulse Current................................................................................91,000A
Catastrophic Surge Circuit ..............................................................................YES
Thermal Fuse...................................................................................................YES
Over/Under Voltage Protection.........................................................................YES
Over-voltage shutoff threshold / Response time........137±4 VAC, 10 milliseconds
Under-voltage shutoff threshold / Response time......95±4 VAC, 500 milliseconds
NOISE FILTRATION:
Filtered Outlet Banks........................................................55 dB (100 KHz - 1 MHz)
Isolation Transformer Outlets
Common Mode........................................................120 dB (100 KHz - 1 MHz)
Normal Mode..............................................................50 dB (100 KHz - 1 MHz)
High-Current Outlets
Normal Mode..............................................................50 dB (100 KHz - 1 MHz)
AC CIRCUIT PROTECTION AND FILTRATION
Dimensions................17.25” W x 12” D x 3.5” H, (4.1” H including feet)
Weight.............................................................................................31 lbs.
Design and specifications subject to change without notice due to product improvement.
Compatibility........................................................................10/100 baseT Ethernet
Clamping Level...................................................................................................8V
Wires Protected.............................................................................pins 1, 2, 3 and 6
Connections...................................................................................................RJ-45
Patented Over/Under Voltage Protection:
The MAX 5510-Pro constantly monitors the AC line
voltage for unsafe voltage conditions such as pro-
longed over voltages and under voltages (brownouts).
These unsafe conditions pose a very dangerous threat
to all electronic equipment within the home. If the
MAX 5510-Pro senses an unsafe power condition, it
will automatically disconnect your equipment from the
power to protect equipment from damage. Once the
voltage returns to a safe level, the MAX 5510-Pro will
automatically reconnect the power.
If the line voltage exceeds the over voltage threshold
or falls below the under voltage threshold, the MAX
5510-Pro will perform the following tasks until line
voltage returns to a safe level:
1. Disconnects power to all connected equipment.
2. Unsafe Voltage LED is activated and will blink
once per second during the unsafe voltage condition.
POWER
POWER
1. Voltage reaches an unsafe high
level and the SurgeGate Plus™
disconnects.
2. Voltage reaches a safe level and
SurgeGate Plus™ automatically
reconnects.
3. Voltage reaches an unsafe low level
and SurgeGate Plus™ disconnects.
4. Voltage reaches a safe level and
SurgeGate Plus™ automatically
reconnects.