Panamax M8-AV-PRO Specifications - M8-Av-Pro
M8-AV-PRO
L629-B 11/09
FEATURES
www.panamax.com
HOME THEATER POWER MANAGEMENT
Power ON/Protection OK LED
(green) Normally ON; indicates
that the surge protector is
functioning properly and that all
connected equipment is protected.
Ground OK LED
(green) Normally ON; indicates
that the wall outlet is properly
wired and grounded.
CATV / Satellite Connectors
2 sets of IN /OUT,
universal coaxial
connectors
8 ft. AC Power Cord
Right Angle with
45 Degree Offset Plug
8 AC Outlets
Outlets 1-4 feature (4 top outlets)
“Balanced Double L” Filtration Circuit
Outlets 5-8 (4 side outlets) for high
current equipment.
ON / OFF Power Switch and
Circuit Breaker Combination
1
2
Accepts Panamax add on data line protection modules
(modules sold separately).
SPECIFICATIONS
Design and specifications subject to
change without notice due to product
upgrades and improvements.
UPC’S, QUANTITIES, WEIGHTS & MEASUREMENTS FOR ORDERING & SHIPPING
Dimensions Weight Dimensions Weight UPC Qty. Dimensions Weight UPC
12” x 5” x 1.75” 3.5 lbs 13.25” x 9.5” x 2.5” 4 Lbs 0 50616 00874 7 6 17.25” x 8.5” x 14” 25 Lbs 50 050616 00874 2
MODEL M8-AV-PRO SINGLE UNIT CARTON MASTER CARTON
1690 Corporate Circle, Petaluma, CA. 94954 • 800-472-5555 or 707-283-5900 • Fax 707-283-5901
(12.5 in. L Including brackets)
Accessory Included:
3 ft. Coax Cable Mounting Brackets
In/Out Telco/LAN Connectors
Telco and LAN Connector RJ-45
Unsafe Voltage LED (red) Normally OFF;
flashes when lit, indicates that incoming
voltages are unsafe and the surge protector
has disconnected the power to
connected equipment.
AC POWER
Protect or Disconnect™ Circuitry___________________Yes
Patented Power Management Circuit*________________Yes
Auto-resetting Overvoltage Shutoff_____________ 144V ±8V
Auto-resetting Undervoltage Shutoff_____________90V ±6V
Thermal Fusing______________________________ Yes
Line Voltage_______________________120VAC, 50/60Hz
Initial Clamping Level_____________200V Peak, 141V RMS
Voltage Protection Rating (UL 1449 3rd Edition, 3,000A)_________500V
UL 991____________________________________Yes
Protection Modes_____________________L-N, L-G, N-G
Maximum Current Rating_________________15A (1800W)
Single Pulse Energy Dissipation_____________1875 Joules
Peak Impulse Current______________________ 65,000 A
DC Trigger
For high current
outlets (5-8)
DC Trigger LED
(green) ON/OFF status depends upon
whether or not a 12VDC signal is being
received from another component
when utilizing.
LAN Protection:
Compatibility____________________________10/100bT
Clamping Level_______________________________7V
Suppression Modes________Differential & Common Ground
Wires Protected_____________________Pins 1, 2, 3, & 6
Connectors___________________RJ-45 Shared with Telco
Telco Protection:
Fuseless/Auto-Resetting________________________Yes
Clamping Level_____________________________260V
Capacitance_________________________30 pf (approx.)
Suppression Modes_____________Metallic & Longitudinal
Wires Protected____________________2 wire, 1 pair (4,5)
Connectors___________________ RJ-45 Shared with LAN
EMI/RFI Noise Filtration__________53dB (100kHz – 1 MHz)
Number of Isolated Banks of Outlets__________________2
Filter Circuits_______1 Common Mode
1 Normal Mode,
1 High-Current Inductorless
Filtered Outlet Banks____________53 dB (100 KHz - 1 MHz)
High-Current Outlets____________50 dB (100 KHz - 1 MHz)
Response Time_____________________________
Universal Coax Protection:
HD Ready__________________________________Yes
Shielded___________________________________Yes
Clamping Level______________________________75V
Frequency Range_____________________ 5MHz - 2.GHz
Insertion Loss____________________________
Connections__________________Female "F", Gold Plated
Bi-Directional______________________________ Yes