Panamax MAX 5100 Owner's Manual - Feature Overview
USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901
3
FEATURE OVERVIEW
Switched Outlets Pushbutton:
1 of 2 Triggers that can activate a turn-on
or shutdown sequence for Outlet Bank 2
and the High-Current Outlets.
Diagnostic Lights:
The MAX
®
5100 is loaded with special features to save your connected
equipment from many different forms of dangerous power disturbances.
Five diagnostic lights on the front panel inform you in the event of either
a power disturbance or when a special feature is activated.
LED Voltmeter:
Displays AC line voltages from 90V to 135V.
High Current Outlet Bank:
Two delayed outlets designed for high-current
components such as amplifiers and powered
subwoofers. The current available to connected
equipment is not limited by the noise filtration
components.
Voltage Sense
Trigger Input:
1/8 inch Mini-Plug jack.
Connect to a remote trigger
device that provides 12VDC
to trigger a startup/shutdown
sequence. This is the second
trigger that will activate the
MAX
®
5100 turn-on or
shutdown sequence. (See
switched outlets pushbutton
on front panel).
High Current Outlets
Turn-On Switch:
3-position slide switch.
Allows adjustment of
the Turn-On delay for
the two High-Current
Outlets. Choose
between 0, 10 and 30
seconds
Outlet Bank 2
Turn-Off Switch:
3-position slide switch.
Allows adjustment of
the Turn-Off delay for
Outlet Bank 2. Choose
between Always-On,
10 and 30 seconds.
Satellite Coax Jacks:
One pair of gold plated
F-Connectors optimized
for Satellite TV signal
line protection.
Cable TV Coax Jacks:
One pair of gold plated
F-Connectors optimized for
Cable TV and non-amplified
Rooftop Antenna signal line
protection.
Telephone Jacks:
In/Out connections
for telephone line or
pay-per-view line
protection.
15A Circuit Breaker:
Opens in the event that equipment plugged
into the MAX
®
5100 draws too much current.
When the white button of the breaker is
visible, the breaker has opened. Reduce
the load and push to reset.
Ground Lug: Provides a common
grounding point for equipment with
separate ground leads
Outlet Bank 1:
Four Always-On, filtered
outlets for audio/video
components that require
constant power to maintain
programmed settings.
Voltmeter Dimmer
Switch:
3-position slide switch.
Choose between low,
medium and high.
Switched Outlets:
Green LED. This light indicates the
status of the “Switched Outlets” push -
button on the front panel and corre -
sponds with the switch position.
DC Voltage Trigger:
Green LED. This light indicates status
of the DC voltage trigger on the back
panel of the MAX
®
5100.
Unsafe Voltage:
Red LED. Under normal voltage conditions, this
light stays off.
Ground Ok:
Green LED. When this light is ON, it
indicates that the wall outlet is prop -
erly wired.
Line Fault:
Red LED. When this light is ON, it is
indicating that the wall outlet has a
reversed line and neutral wire, or
there is no ground present. This
light will remain OFF if the wall
outlet is properly wired.
Outlet Bank 2:
Four switched, filtered
outlets for audio/video
components that do not
require constant power.