Panasonic CS-E12PKR Operating Instructions Manual - page 9
AAF
9
English
Operation conditions
Use this air conditioner under the following temperature range.
DBT : Dry bulb temperature
WBT : Wet bulb temperature
Temperature (°C)
Indoor
Outdoor
DBT
WBT
DBT
WBT
COOL
Max. 32
23
46
26
Min. 16
11
5
4
HEAT
Max. 30
-
24
18
Min. 16
-
-15
-16
after
his
tes
lected,
FORT
l
C
C
C
C
Sunlight Sensor operation
Set
temperature
HEAT
COOL/DRY
+1 °C
-1 °C
-1 °C
ECONAVI ; Detecting sunlight intensity, the unit adjust temperature to save energy.
Ambient condition
Mode
ECONAVI is activated,
the unit maintains set
temperature until a high
sunlight intensity is detected.
The sunlight sensor detects
sunlight intensity during
weather or day/night
changes, and the unit adjusts
temperature.
• In a room without window or with thick curtain, the sunlight sensor will judge as cloudy/night.
The human activity sensor will also scan for area of heat source and movement in a room.
Detection area
Human activity indicator
120º
7m
At left area
At center / multiple area
At right area
The unit judges human activity area for a few seconds before indicator updates. Based on area activeness
horizontal airfl ow direction louver will adjust either fi x at predetermined position or swing left/right periodically.
• The human activity sensor performance is infl uenced by indoor unit location, movement speed, temperature
range, etc.
• The human activity sensor may:
- mistakenly detect an object with heat source & movement similar to human, such as pets, etc.
- mistakenly detect as non-heat source & movement if a human stays motionless for certain period of time.
• Do not place large objects near the sensor and keep away heating units or humidifi er from the sensor’s detection
area. They may cause sensor malfunction.
To
learn more...
F569361_EN.indd 9
F569361_EN.indd 9
7/9/2013 8:48:47 AM
7/9/2013 8:48:47 AM