Panasonic CS-ME10EB1E Service Manual

Other manuals for CS-ME10EB1E: Operating Instructions Manual

Summary of CS-ME10EB1E

  • Page 1

    1 safety precautions 3 2 features 5 3 functions 6 3.1. Remote control 6 3.2. Indoor unit 7 4 product specifications 9 5 dimensions 10 5.1. Cassette type 10 5.2. Grille 12 6 refrigeration cycle diagram 13 7 block diagram 14 8 wiring diagram 15 9 electronic circuit diagram 16 10 operation details (fun...

  • Page 2

    13.1. Operation characteristics 40 14 exploded view & replacement parts list 45 14.1. Exploded view 45 14.2. Replacement parts list 46 2 cs-me7eb1e / cs-me10eb1e / cs-me12eb1e / cs-me14eb1e operating instructions of this product can be referred at following web site. Http://phaam.Panasonic.Com.My.

  • Page 3: 1 Safety Precautions

    1 safety precautions 3 cs-me7eb1e / cs-me10eb1e / cs-me12eb1e / cs-me14eb1e.

  • Page 4

    4 cs-me7eb1e / cs-me10eb1e / cs-me12eb1e / cs-me14eb1e.

  • Page 5: 2 Features

    · serviceability − − − − self diagnosis − − − − test run at both cooling and heating rated frequency · built-in drain pump − − − − a drain pump is built in. The pipe can rise to 200 mm above the drain outlet. 2 features · product − − − − a single outdoor unit enables air conditioning of up to four s...

  • Page 6: 3 Functions

    3 functions 3.1. Remote control 6 cs-me7eb1e / cs-me10eb1e / cs-me12eb1e / cs-me14eb1e.

  • Page 7

    3.2. Indoor unit 7 cs-me7eb1e / cs-me10eb1e / cs-me12eb1e / cs-me14eb1e.

  • Page 8

    8 cs-me7eb1e / cs-me10eb1e / cs-me12eb1e / cs-me14eb1e.

  • Page 9: 4 Product Specifications

    4 product specifications model cs-me7eb1e cs-me10eb1e cs-me12eb1e cs-me14eb1e item cassette type power source outdoor power (single 230v 50hz) air volume cooling m 3 /min. 9.1 9.6 9.5 heating m 3 /min. 10.1 10.9 9.8 noise level cooling (power) db(a) (db) hi:40(53) lo:32(45) hi:41(54) lo:32(45) hi:42...

  • Page 10: 5 Dimensions

    5 dimensions 5.1. Cassette type 10 cs-me7eb1e / cs-me10eb1e / cs-me12eb1e / cs-me14eb1e.

  • Page 11

    11 cs-me7eb1e / cs-me10eb1e / cs-me12eb1e / cs-me14eb1e.

  • Page 12

    5.2. Grille 12 cs-me7eb1e / cs-me10eb1e / cs-me12eb1e / cs-me14eb1e.

  • Page 13

    6 refrigeration cycle diagram 13 cs-me7eb1e / cs-me10eb1e / cs-me12eb1e / cs-me14eb1e.

  • Page 14: 7 Block Diagram

    7 block diagram cs-me7eb1e/me10eb1e/me12eb1e/me14eb1e 14 cs-me7eb1e / cs-me10eb1e / cs-me12eb1e / cs-me14eb1e.

  • Page 15: 8 Wiring Diagram

    8 wiring diagram 15 cs-me7eb1e / cs-me10eb1e / cs-me12eb1e / cs-me14eb1e.

  • Page 16

    9 electronic circuit diagram 16 cs-me7eb1e / cs-me10eb1e / cs-me12eb1e / cs-me14eb1e cs-me7eb1e cs-me10eb1e cs-me12eb1e cs-me14eb1e.

  • Page 17

    17 cs-me7eb1e / cs-me10eb1e / cs-me12eb1e / cs-me14eb1e.

  • Page 18

    10 operation details (functions & protection) 10.1. Simultaneous operation control 1. Operation modes which can be selected using the remote control unit: automatic, cooling, soft dry, heating, fan operation 2. Types of operations modes which can be performed simultaneously · cooling operation and c...

  • Page 19

    10.2. Airflow direction control the following shows how louver operation changes depending on the direction set with the air swing button and other operating conditions. Cooling and dry heating · the louver stops at the close position when the power switch or breaker is on. · the louver stops at the...

  • Page 20

    10.3. Indoor fan control · the following shows how fan speed changes depending on the setting made with the fan speed button and other operating conditions. · actual fan speed may differ from that you set with remote control. 20 cs-me7eb1e / cs-me10eb1e / cs-me12eb1e / cs-me14eb1e.

  • Page 21

    21 cs-me7eb1e / cs-me10eb1e / cs-me12eb1e / cs-me14eb1e.

  • Page 22

    10.4. Drain pump control basic operation · the drain pump starts 50 seconds after the indoor unit starts or the thermostat comes on (i.E., 10 seconds after the fan motor starts). The drain pump stops 30 seconds after the indoor unit stops or the thermostat turns off. · the drain pump repeats a cycle...

  • Page 23

    10.5. Auto restart control · if there is a power failure, operation will automatically be restarted when the power is resumed. It will start with the previous operation mode and airflow direction. (time delay safety control is valid) 1. Control start conditions the 24-hour timer must not be set. The...

  • Page 24

    10.6. Other indoor unit operation functions 10.6.1. Auto button proceed with operation when the air conditioner is stopped. (when the auto button is pressed during operation, the air conditioner is stopped.) 1. Emergency operation press the auto button and release it within 5 seconds to perform emer...

  • Page 25

    10.6.2. Drain test when installing the unit and you want the drain pump to operate independently, press the drain test switch to operate it for about 5 minutes. 25 cs-me7eb1e / cs-me10eb1e / cs-me12eb1e / cs-me14eb1e.

  • Page 26

    10.6.3. Self diagnosis display 10.6.3.1. Breakdown self diagnosis function (three digits alphanumeric code) · once abnormality has been detected during operation, the unit will immediately stop its operation. (timer led blinks.) · although timer led goes off when power supply is turned off, if the u...

  • Page 27

    10.6.3.2. Error co de 27 cs-me7eb1e / cs-me10eb1e / cs-me12eb1e / cs-me14eb1e symbol diagnosis diagnosis method h11 indoor / outdoor abnormal communication this error occurs when indoor/outdoor unit communication fails to be established after 30 seconds or more. 1. Measure the voltage of the indoor/...

  • Page 28

    28 cs-me7eb1e / cs-me10eb1e / cs-me12eb1e / cs-me14eb1e symbol diagnosis diagnosis method h30 outdoor discharge pipe temp. Sensor disconnected discharge sensor when the condensation temperature is higher than the discharge temperature + (plus) 6°c, a sensor disconnection is detected, operation stops...

  • Page 29

    29 cs-me7eb1e / cs-me10eb1e / cs-me12eb1e / cs-me14eb1e symbol diagnosis diagnosis method h99 indoor operating unit freezing the restriction on the compressor frequency is started when the indoor unit heat exchanger temperature is between 8°c and 12°c. Operation stops if a temperature below 0°c cont...

  • Page 30

    30 cs-me7eb1e / cs-me10eb1e / cs-me12eb1e / cs-me14eb1e symbol diagnosis diagnosis method f97 compressor high discharge temperature this error occurs and operation stops when this happens on 6 occasions (it is cleared when the operation is normal for 20 minutes). 1. Check the refrigerating cycle: ga...

  • Page 31

    Cs-me7eb1e / cs-me10eb1e / cs-me12eb1e / cs-me14eb1e 31 11 installation instructions.

  • Page 32

    Cs-me7eb1e / cs-me10eb1e / cs-me12eb1e / cs-me14eb1e 32.

  • Page 33

    Cs-me7eb1e / cs-me10eb1e / cs-me12eb1e / cs-me14eb1e 33.

  • Page 34

    Cs-me7eb1e / cs-me10eb1e / cs-me12eb1e / cs-me14eb1e 34.

  • Page 35

    Cs-me7eb1e / cs-me10eb1e / cs-me12eb1e / cs-me14eb1e 35.

  • Page 36: 12 Disassembly Of Parts

    12 disassembly of parts high voltages are generated in the electrical parts area by the capacitor, ensure that the capacitor has discharged sufficiently before proceeding with repair work. Failure to heed this caution may result in electric shocks. 12.1. Detaching the fan motor and cross flow fan 1)...

  • Page 37

    8) detach the air guide and unscrew the screw on the heat exchanger. 9) detach the float switch and unscrew the 3 screws and disengage the 2 catches on the fan motor holder. 10) loosen the screw fixing the shaft between the cross flow fan and the fan motor and detach the fan motor. 11) remove the cr...

  • Page 38

    3) loosen the screw on the cover and detach the cover. 4) unscrew the 2 screws on the control section cover and detach all connectors. 5) disengage the catch on the control board and remove it. 38 cs-me7eb1e / cs-me10eb1e / cs-me12eb1e / cs-me14eb1e.

  • Page 39

    12.4. Detaching the louver motor 3) loosen the screw on the cover and detach the cover. 4) unscrew the 2 screws on the control section cover and detach the connector for the louver motor. 5) unscrew the screw and disengage the 2 catches on the air outlet grille. 6) unscrew the 2 screws on the louver...

  • Page 40: 13 Technical Data

    13 technical data 13.1. Operation characteristics 40 cs-me7eb1e / cs-me10eb1e / cs-me12eb1e / cs-me14eb1e.

  • Page 41

    41 cs-me7eb1e / cs-me10eb1e / cs-me12eb1e / cs-me14eb1e.

  • Page 42

    42 cs-me7eb1e / cs-me10eb1e / cs-me12eb1e / cs-me14eb1e.

  • Page 43

    43 cs-me7eb1e / cs-me10eb1e / cs-me12eb1e / cs-me14eb1e.

  • Page 44

    44 cs-me7eb1e / cs-me10eb1e / cs-me12eb1e / cs-me14eb1e.

  • Page 45

    14 exploded view & replacement parts list 14.1. Exploded view note: the above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts. 45 cs-me7eb1e / cs-me10eb1e / cs-me12eb1e / cs-me14eb1e.

  • Page 46

    14.2. Replacement parts list ref. No. Part name & description q´ty part no. Remarks cs-me7eb1e cs-me10eb1e cs-me12eb1e cs-me14eb1e 1 float switch 1 cwa121207 ← ← ← ← ← ← ← ← ← ← ← ← l 2 thermal fuse 1 cwa16c1020j ← ← ← ← ← ← ← ← ← ← ← ← l 3 terminal board complete 1 cwa28k1045j ← ← ← ← ← ← ← ← ← ← ←...