Panasonic CS-SA12CKP Operating Instructions Manual - page 9
ENGLISH
8
EVALUATION OF THE PERFORMANCE
●
Operate the unit for 15 minutes or more;
●
Measure the temperature of the intake and outlet air;
●
The temperature difference is more than 8˚C during
Cooling operation or more than 14°C during Heating
operation.
If the unit fulfils the above conditions, the unit is in normal
operation.
Air intake vent
Thermometer
Air outlet vent
1) This appliance must be earthed.
2) If the supply cord is damaged or need to be replaced, it must be replaced by the manufacturer or its service agent
or a similarly qualified person in order to avoid a hazard.
3) Remove power plug or disconnect from the mains before servicing this appliance.
4) Do not repair by yourself .
In case of malfunction of this appliance, do not repair by yourself.
Contact to the sales dealer or service dealer for a repair.
5) Do not use in an explosive atmosphere.
Do not use this appliance in a potentially explosive atmosphere.
6) Disconnect the power plug (isolation from main power supply).
Disconnect the power plug from the receptacle, or switch off the breaker, or switch off the power, disconnecting
mains plug to isolate the equipment from the main power supply in case of an emergency.
WARNING
DISCONNECT THE MAINS PLUG FROM THE SUPPLY SOCKET WHEN NOT IN USE , WHERE SUPPLY
CONNECTION IS VIA MAINS PLUG.
Airborne noise :
A-weighted sound pressure level of this appliance is less than 70dB(A) under the JIS C 9612 test conditions.
Maximum cooling operation
1 m from the unit
CAUTION
IMPORTANT
The wires in this mains lead are coloured in accordance with the following code :
Green and Yellow
:
Earth
Blue
:
Neutral
Brown
:
Live
“As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying
the terminals in your plug, proceed as follows:
The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked by the letter
E or by safety earth symbol
or coloured green or green and yellow.
The wire which is coloured blue must be connected to the terminal which is marked with letter N or coloured black.
The wire which is coloured brown must be connected to the terminal which is marked with letter L or coloured red.”
Use this air conditioner under the following conditions:
DBT: Dry Bulb Temp.
Indoor
Outdoor
WBT: Wet Bulb Temp.
DBT
WBT
DBT
WBT
Maximum Temperature – Cooling
32
23
43
26
(Maximum Temperature – Heating)
(30)
(–)
(24)
(18)
Minimum Temperature – Cooling
16
11
16
11
(Minimum Temperature – Heating)
(2)
(–)
(–5)
(–6)
Unit in ˚C
F563553/01-08/EN
5/6/02, 10:34 am
9