Panasonic Digital Fiber Sensor FX-301 Specification Sheet

Manual is about: Panasonic Digital Fiber Sensor Specification Sheet

Summary of Digital Fiber Sensor FX-301

  • Page 1

    Fx-301 digital fiber sensor superior performance and advanced user-friendly multi-functionality enables expert usage on the very first day 68 series long-range sensing made possible with built-in optical lens stable long-term sensing enhanced worksite-friendly installability for the first time in th...

  • Page 2: Fx-301

    69 fx-301 even beginners can quickly learn how to use the mode navi mode navi uses six indicators to display the amplifier’s basic operations. The current operating mode can be confirmed at a glance, so even a first time user can easily operate the amplifier without becoming confused. Easy maintenan...

  • Page 3: Fx-301

    70 fx-301 4 types of light sources available in addition to our red led (four-chemical emitting element) type, the blue, green, and infrared led types are also provided to correspond to your specific application. Easy code input setting every function can be directly set merely by the input of a fou...

  • Page 4: Fx-301

    71 fx-301 optional units for greater freedom and control when installing sensor-plc connection system this wire-saving system enables the collective connection of up to 16 i/o devices with an mil connector. Scattered installation is also possible with the help of a sensor separate unit. Sc series ba...

  • Page 5: Fx-301

    72 fx-301 order guide type appearance model no. Emitting element output npn output pnp output digital fx-301 fx-301b fx-301g fx-301h fx-301p fx-301bp fx-301gp fx-301hp red led blue led green led infrared led red led blue led green led infrared led amplifiers npn open-collector transistor pnp open-co...

  • Page 6: Fx-301

    73 fx-301 ft-fm10l ft-sfm2l ft-b8 ft-nb8 ft-fm2 ft-fm2s ft-fm2s4 ft-t80 ft-sfm2 ft-n8 ft-nfm2 ft-nfm2s ft-nfm2s4 ft-snfm2 ft-r80 ft-v10 ft-sfm2sv2 ft-v22 ft-v41 140 5.512 r25 mm r0.984 in r25 mm r0.984 in fiber r25 mm r0.984 in sleeve r25 mm r0.984 in r25 mm r0.984 in fiber r25 mm r0.984 in sleeve r...

  • Page 7: Fx-301

    74 fx-301 ft-wv42 ft-z8h ft-z8e ft-z8 ft-p80 ft-p60 ft-p40 ft-p2 ft-ps1 ft-w8 ft-ws3 ft-ws8 ft-wz8h ft-wz8e ft-wz8 ft-wkv8 ft-ws8l " 0.3 mm " 0.012 in opaque object " 0.25 mm " 0.010 in opaque object ft-wa30 ft-wa8 400 15.748 200 7.874 140 5.512 240 9.449 120 4.724 80 3.150 80 3.150 40 1.575 25 0.98...

  • Page 8: Fx-301

    75 fx-301 r25 mm r0.984 in r25 mm r0.984 in 600 23.622 300 11.811 220 8.661 120 4.724 60 2.362 40 1.575 120 4.724 60 2.362 40 1.575 80 3.150 35 1.378 10 0.394 3 0.118 2 0.079 1 0.039 14 0.551 7 0.276 4 0.157 130 5.118 64 2.520 45 1.772 300 11.811 150 5.906 110 4.331 60 2.362 30 1.181 20 0.787 60 2.3...

  • Page 9: Fx-301

    76 fx-301 100 3.937 50 1.969 35 1.378 44 1.732 22 0.866 14 0.551 100 3.937 50 1.969 35 1.378 72 2.835 36 1.417 26 1.024 320 12.598 160 6.299 120 4.724 160 6.299 80 3.150 50 1.969 120 4.724 60 2.362 35 1.378 100 3.937 50 1.969 30 1.181 36 1.417 18 0.709 12 0.472 50 1.969 25 0.984 18 0.709 22 0.866 11...

  • Page 10: Fx-301

    77 fx-301 fd-b8 fd-5 fd-fm2 fd-fm2s fd-fm2s4 fd-t80 fd-t40 fd-s80 fd-n8 fd-n4 fd-nfm2 fd-nfm2s fd-nfm2s4 fd-snfm2 fd-r80 fd-sfm2sv2 fd-v41 80 3.150 40 1.575 26 1.024 46 1.811 23 0.906 15 0.591 46 1.811 23 0.906 15 0.591 46 1.811 23 0.906 15 0.591 46 1.811 23 0.906 15 0.591 16 0.630 8 0.315 5 0.197 4...

  • Page 11: Fx-301

    78 fx-301 fd-wkz1 fd-w8 fd-w44 fd-wt8 fd-ws8 fd-wt4 fd-wg4 fd-wsg4 fd-wl41 fd-wl42 fd-wv42 fd-p80 fd-p60 fd-p50 fd-p40 fd-p2 23 0.906 11 0.433 8 0.315 5 0.197 2.5 0.098 1.5 0.059 23 0.906 11 0.433 8 0.315 5 0.197 2.5 0.098 1.5 0.059 11 0.433 5 0.197 3 0.118 40 1.575 20 0.787 13 0.512 20 0.787 10 0.3...

  • Page 12: Fx-301

    79 fx-301 fd-eg1 fd-eg2 fd-eg3 fd-e12 fd-e22 fd-en500s1 fd-enm1s1 list of fibers special use wide beam arr a y high precision ultr a-small diameter liquid le v el sensing t ough fle xib le fix ed-f ocus reflectiv e special use fibers (reflective type) :long :std :fast :s-d sensing range (mm in ) (no...

  • Page 13: Fx-301

    80 fx-301 fd-h35-m2 fd-h35-m2s6 fd-h20-m1 fd-h35-20s fd-h20-21 fd-h30-l32 fd-h18-l31 fd-h13-fm2 fd-6v 36 1.417 18 0.709 12 0.472 22 0.866 11 0.433 7 0.276 36 1.417 18 0.709 12 0.472 20 0.787 11 0.433 7 0.276 26 1.024 13 0.512 9 0.354 20 0.787 10 0.394 7 0.276 12 0.472 6 0.236 4 0.157 20 0.787 10 0.3...

  • Page 14: Fx-301

    81 fx-301 1,000 1,300 1,300 800 1,000 1,100 900 1,100 750 500 500 900 ft-b8 ft-fm2 ft-t80 ft-r80 ft-w8 ft-p80 ft-p60 ft-p81x ft-h35-m2 ft-h20w-m1 ft-h20w-m2 ft-h20-m1 3,500 (note 3) 3,500 (note 3) 3,500 (note 3) 3,500 (note 3) 3,500 (note 3) 3,500 (note 3) 3,500 (note 3) 3,500 (note 3) 3,500 (note 3...

  • Page 15: Fx-301

    82 fx-301 fx-ct2 fx-ct1 ftp-500 (0.5 m 1.640 ft ) ftp-1000 (1 m 3.281 ft ) ftp-1500 (1.5 m 4.921 ft ) ftp-n500 (0.5 m 1.640 ft ) ftp-n1000 (1 m 3.281 ft ) ftp-n1500 (1.5 m 4.921 ft ) fdp-500 (0.5 m 1.640 ft ) fdp-1000 (1 m 3.281 ft ) fdp-1500 (1.5 m 4.921 ft ) fdp-n500 (0.5 m 1.640 ft ) fdp-n1000 (1...

  • Page 16: Fx-301

    83 fx-301 12 to 24 v dc 10 % ripple p-p 10 % or less red led / infrared led type > normal operation: 960 mw or less current consumption 40 ma or less at 24 v supply voltage eco mode: 600 mw or less current consumption 25 ma or less at 24 v supply voltage npn open-collector transistor • maximum sink ...

  • Page 17: Fx-301

    84 fx-301 r25 mm r0.984 in or more [sleeve of a head with sleeve:r10 mm r0.394 in or more (note 1)] 40 to 70 °c 40 to 158 °f ft-sfm2sv2: 20 to 70 °c 4 to 158 °f ft-v22, fd-sfm2sv2: 20 to 60 °c 4 to 140 °f ft-v41, fd-v41, ft-v10: 40 to 60 °c 40 to 140 °f 35 to 85%rh (no dew condensation or icing allo...

  • Page 18: Fx-301

    85 fx-301 r10 mm r0.394 in or more 40 to 100 °c 40 to 212 °f (note 1) polyethylene polyetherimide (lens: polycarbonate) 1 fiber attachment set, fx-ct2 (fiber cutter) 1pc. Tying bands 4 pcs., anti-slip tubes 2 pcs. Protective tube: r40 mm r1.575 in or more fiber: r15 mm r0.591 in or more 40 to 125 °c...

  • Page 19: Fx-301

    86 fx-301 i/o circuit and wiring diagrams i/o circuit diagram wiring diagram notes: 1) the quick-connection sub cable does not have v (brown) and 0 v (blue). Notes: 2) 50 ma max., if five amplifiers, or more, are connected together. Symbols … d : reverse supply polarity protection diode z d : surge ...

  • Page 20: Fx-301

    87 fx-301 sensing characteristics (typical) parallel deviation ft-fm10l ft-sfm2l ft-b8 ft-nb8 ft-fm2 ft-fm2s ft-fm2s4 ft-t80 ft-sfm2 ft-n8 ft-nfm2 ft-nfm2s ft-nfm2s4 ft-snfm2 ft-r80 ft-v10 ft-sfm2sv2 ft-v22 ft-v41 l thru-beam type thru-beam type thru-beam type thru-beam type thru-beam type thru-beam...

  • Page 21: Fx-301

    88 fx-301 ft-ws8l ft-w8 ft-ws8 ft-ws3 ft-w4 ft-ws4 ft-wz8h fz-wz8e thru-beam type thru-beam type thru-beam type ft-wz8 thru-beam type thru-beam type thru-beam type thru-beam type parallel deviation ft-wa30 ft-a30 ft-wa8 ft-a8 l thru-beam type thru-beam type horizontal direction vertical direction ho...

  • Page 22: Fx-301

    89 fx-301 parallel deviation ft-wv42 thru-beam type horizontal direction vertical direction horizontal direction vertical direction ft-z8 ft-p80 ft-p60 ft-p40 thru-beam type thru-beam type thru-beam type thru-beam type ft-z8h ft-z8e thru-beam type thru-beam type ft-p2 ft-ps1 thru-beam type thru-beam...

  • Page 23: Fx-301

    90 fx-301 parallel deviation ft-kv1 thru-beam type horizontal direction vertical direction ft-kv8 thru-beam type horizontal direction vertical direction ft-p81x ft-h35-m2 ft-h35-m2s6 ft-h20w-m1 ft-h20w-m2 ft-h20-m1 thru-beam type thru-beam type thru-beam type thru-beam type ft-e12 ft-e22 thru-beam t...

  • Page 24: Fx-301

    91 fx-301 ft-z802y ft-6v ft-60v thru-beam type thru-beam type thru-beam type parallel deviation parallel deviation with fx-le2 (super-expansion lens) applied on both sides parallel deviation with fx-le1 (expansion lens) applied on both sides ft-b8 ft-w8 ft-p80 ft-h35-m2 thru-beam type thru-beam type...

  • Page 25: Fx-301

    92 fx-301 parallel deviation with fx-sv1 (side-view lens) applied on both sides parallel deviation with fx-le2 (super-expansion lens) applied on both sides ft-b8 thru-beam type horizontal direction vertical direction ft-w8 thru-beam type horizontal direction ft-p80 thru-beam type ft-h35-m2 thru-beam...

  • Page 26: Fx-301

    93 fx-301 fd-b8 fd-5 fd-fm2 fd-t80 fd-s80 fd-fm2s fd-fm2s4 fd-t40 fd-nfm2 fd-nfm2s fd-nfm2s4 fd-snfm2 reflective type reflective type reflective type reflective type sensing fields fd-sfm2sv2 reflective type horizontal direction vertical direction horizontal direction vertical direction horizontal d...

  • Page 27: Fx-301

    94 fx-301 fd-a15 reflective type horizontal direction vertical direction fd-afm2 fd-afm2e reflective type horizontal direction vertical direction fd-eg1 fd-eg2 reflective type reflective type fd-g4 fd-g6 reflective type reflective type sensing fields fd-p60 fd-p50 reflective type reflective type fd-...

  • Page 28: Fx-301

    95 fx-301 fd-eg3 reflective type fd-en500s1 reflective type fd-e12 reflective type fd-e22 reflective type sensing fields fd-enm1s1 fd-p81x reflective type reflective type fd-g6x reflective type fd-h35-m2 fd-h35-m2s6 reflective type fd-h20-m1 fd-h35-20s reflective type reflective type fd-h20-21 refle...

  • Page 29: Fx-301

    96 fx-301 • make sure that the power supply is off while cascading or removing the amplifier. • make sure to check the allowable ambient temperature, as it depends on the number of amplifiers connected in cascade. • in case two, or more, amplifiers are connected in cascade, make sure to mount them o...

  • Page 30: Fx-301

    97 fx-301 the threshold value is displayed. ‘ ’ blinks in the digital display. The incident light intensity appears in the digital display and the setting is complete. 6 5 7 8 if jog switch is turned to the ‘ ’ side, ‘ ’ scrolls (twice) the display from right to left, and the threshold level is shif...

  • Page 31: Fx-301

    98 fx-301 precautions for proper use amplifier threshold value fine adjustment key-lock function press mode key to light up mode indicator / adj (yellow). When jog switch is pressed, the threshold value is confirmed. 1 2 2 step description display in case the threshold value is to be increased (sens...

  • Page 32: Fx-301

    99 fx-301 precautions for proper use amplifier pro mode table for pro mode settings • refer to the ‘fiber sensor guide book’ for more details pertaining to the pro mode settings and procedures. • the above can also be download from ‘sunx fiber sensor homepage’ (http://www.Fiber-sensor.Com) • pro set...

  • Page 33: Fx-301

    100 fx-301 m3 m4 m5 m6 m14 0.39 n·m 0.58 n·m 350 °c 662 °f heat-resistant fiber and ft-h20w-m : 0.98 nm, fd-h35-20s: 0.58 n m 0.98 n·m 350 °c 662 °f heat-resistant fiber: 1.96 n m 1.47 n m precautions for proper use fiber ft-ps1 fd-e12 ft-v22 ft-41, fd-v41 ft-sfm2sv2 fd-eg1 ft-wv42 fd-wv42 fd-sfm2sv...

  • Page 34: Fx-301

    101 fx-301 precautions for proper use fiber • mount the fiber head by using the enclosed set of screws. The tightening torque should be 0.15 n m or less • if the fiber head is mounted in places subject to vibrations or shocks, use a screw-locking adhesive, etc. • mount each fiber head as given below...

  • Page 35: Fx-301

    • protect the amplifier from heat radiation or hot air. • with the 350 c 662 °f heat-resistant type fiber, the surface of the fiber head or the spiral may be discolored by heat. However, this does not affect its performance. 102 fx-301 connection with reflective coaxial type fiber • with reflective ...

  • Page 36: Fx-301

    Fx-at10, fx-at13 > 1 thread the fiber cable through the gland and holder separately, and screw the gland into the holder clockwise. 2 insert the fiber cables one by one into the holes for "1.0 mm " 0.039 in or "1.3 mm " 0.051 in fiber cable of the fiber cutter (fx-ct2) from the direction shown in th...

  • Page 37: Fx-301

    104 fx-301 fiber precautions for proper use . Fiber cutter (fx-ct2) • to cut the fiber cables, insert them from the direction shown below. (fiber cable insertion direction) 1 slide part of the fiber cutter fully upward till it stops. 2 insert the fiber cables, mounted in the attachment, till they st...

  • Page 38: Fx-301

    105 fx-301 fiber precautions for proper use . Ft-l8y/v8y chemical-resistant type fiber • do not use it in the following chemicals: dissolved alkali metals (natrium, potassium or lithium), fluorine gas (f 2 ), cif 3 , of 2 (including gaseous state). • the beam axis mark is indicated on the side-view ...

  • Page 39: Fx-301

    106 fx-301 precautions for proper use . Fiber fd-f4 and fd-f9 liquid level sensing fiber • mount the fiber head on a pipe with the attached tying bands and anti-slip tubes as shown in the figure below. Make sure that the release lever is retracted (position as in the fig.) before mounting. Fasten tw...

  • Page 40: Fx-301

    107 fx-301 precautions for proper use . Fiber cautions for fx-mr5 side-view zoom lens usage • the spot diameter and the sensing range are adjustable by the screw-in depth as follows. Fitting protective tube • the threaded head free-cut fiber can be fitted with a protective tube. • the maximum tighte...

  • Page 41: Fx-301

    108 fx-301 dimensions (unit: mm in ) main cable (optional) cn-73-c1 cn-73-c2 cn-73-c5 sub cable (optional) cn-71-c1 cn-71-c2 cn-71-c5 amplifier mounting bracket (optional) ms-din-2 end plate (optional) ms-din-e model no. Cn-71-c1 cn-71-c2 cn-71-c5 length (mm in ) 1,000 39.370 2,000 78.740 5,000 196....

  • Page 42: Fx-301

    109 fx-301 dimensions (unit: mm in ) toothed lock washer "23 " 0.906 ft-fm10l free-cut ft-sfm2l ft-b8 ft-nb8 ft-fm2 toothed lock washer "8.5 " 0.335 ft-fm2s ft-fm2s4 ft-t80 ft-sfm2 ft-n8 ft-nfm2 thru-beam type fibers with fx-at3 free-cut with fx-at3 free-cut with fx-at3 free-cut with fx-at5 free-cut...

  • Page 43: Fx-301

    110 fx-301 dimensions (unit: mm in ) ft-r80 free-cut ft-v10 ft-sfm2sv2 ft-v22 15 0.591 ft-v41 ft-wa30 ft-wa8 ft-wz8h ft-wz8e thru-beam type fibers with fx-at3 with fx-at2 free-cut with fx-at3 with fx-at5 free-cut free-cut with fx-at3 with fx-at3 free-cut free-cut with fx-at4 free-cut with fx-at3 fre...

  • Page 44: Fx-301

    111 fx-301 dimensions (unit: mm in ) ft-ws8l free-cut ft-w8 ft-ws3 ft-ws8 ft-w4 ft-ws4 ft-wv42 ft-z8h ft-z8e ft-z8 thru-beam type fibers with fx-at3 free-cut with fx-at3 free-cut with fx-at3 free-cut with fx-at4 with fx-at5 free-cut free-cut with fx-at3 with fx-at3 free-cut free-cut with fx-at4 free...

  • Page 45: Fx-301

    112 fx-301 dimensions (unit: mm in ) ft-p40 free-cut ft-p2 ft-ps1 ft-a30 ft-a8 ft-afm2 ft-afm2e ft-k8 ft-kv8 ft-kv1 thru-beam type fibers with fx-at4 with fx-at2 free-cut with fx-at3 free-cut with fx-at3 free-cut with fx-at2 with fx-at3 with fx-at3 free-cut free-cut with fx-at3 free-cut with fx-at3 ...

  • Page 46: Fx-301

    113 fx-301 dimensions (unit: mm in ) 19.5 0.768 ft-p81x ft-h35-m2 toothed lock washer"8.5 " 0.335 [stainless steel (sus)] ft-h35-m2s6 ft-h20w-m1 ft-h20w-m2 ft-h20-m1 ft-h13-fm2 15 0.591 ft-z802y ft-l8y ft-v8y thru-beam type fibers with fx-at2 with fx-at2 free-cut with fx-at3 free-cut with fx-at3 fre...

  • Page 47: Fx-301

    114 fx-301 dimensions (unit: mm in ) fd-b8 free-cut fd-5 fd-fm2 fd-fm2s fd-fm2s4 fd-t80 fd-t40 fd-s80 fd-n8 fd-n4 fd-nfm2 reflective type fibers with fx-at3 free-cut with fx-at3 free-cut with fx-at5 free-cut with fx-at5 with fx-at10 free-cut with fx-at2 with fx-at3 free-cut free-cut with fx-at4 free...

  • Page 48: Fx-301

    115 fx-301 dimensions (unit: mm in ) " 4 " 0.157 fd-r80 free-cut fd-v41 fd-sfm2sv2 fd-wkz1 fd-w8 fd-w44 fd-wt8 fd-ws8 fd-wt4 fd-wg4 reflective type fibers with fx-at3 free-cut with fx-at3 free-cut with fx-at3 free-cut with fx-at5 free-cut free-cut with fx-at4 with fx-at4 with fx-at3 free-cut free-cu...

  • Page 49: Fx-301

    116 fx-301 dimensions (unit: mm in ) fd-wl42 free-cut fd-wv42 fd-p80 12 0.472 fd-p60 fd-p50 fd-p40 fd-p2 fd-a15 fd-afm2 fd-afm2e reflective type fibers with fx-at4 with fx-at5 with fx-at2 with fx-at3 with fx-at6 free-cut free-cut free-cut free-cut with fx-at4 with fx-at5 with fx-at4 with fx-at3 with...

  • Page 50: Fx-301

    117 fx-301 dimensions (unit: mm in ) fd-eg1 fd-eg2 with fx-at2 with fx-at2 with fx-at2 with fx-at5 with fx-at2 with fx-at2 fd-e12 ("3.2) ("0.126) model no. Tube (pvc) fd-e22 fd-eg3 15 0.591 15 0.591 fd-en500s1 fd-enm1s1 fd-l43 free-cut details of sensing part details of sensing part details of sensi...

  • Page 51: Fx-301

    118 fx-301 dimensions (unit: mm in ) fd-l41 free-cut fd-l42 with fx-at4 with fx-at4 with fx-at3 with fx-at2 with fx-at4 with fx-at4 with fx-at6 free-cut fd-l4 free-cut fd-f41 fd-f91 fd-f4 fd-f9 free-cut fd-f8y free-cut toothed lock washer "11 " 0.433 fd-p81x fd-g6x free-cut details of sensing part d...

  • Page 52: Fx-301

    119 fx-301 dimensions (unit: mm in ) fd-h35-m2 fd-h35-m2s6 fd-h20-m1 fd-h30-l32 fd-h20-21 fd-h35-20s fd-h18-l31 fd-h13-fm2 with fx-at3 free-cut free-cut with fx-at3 fd-6v fx-le1 details of sensing part details of sensing part details of sensing part details of sensing part details of sensing part de...

  • Page 53: Fx-301

    120 fx-301 dimensions (unit: mm in ) fx-le2 fx-sv1 super-expansion lens (optional) side-view lens (optional) fv-le1 fv-br1 expansion lens (for vacuum type fiber optional) photo-terminal (for vacuum type fiber optional) ft-j6 fx-mr1 fiber at atmospheric side (for vacuum type fiber optional) pinpoint ...

  • Page 54: Fx-301

    121 fx-301 dimensions (unit: mm in ) 16 0.630 ms-ex-3 ftp- fdp- mounting bracket for fd-wkz1 fb-1 fx-ct2 fx-at2 fx-at3 fx-at4 fx-at5 fx-at6 mounting bracket for fx-mr2 (accessory for fx-mr2) material: brass (nickel plated) material: spcc-sd (zinc chromate plated) fx-ct2 is not attached with the ft-n...

  • Page 55: Fx-301-F

    Fx-301-f digital fiber sensor for leak detection / liquid detection fibers only easy operation even for beginners! Optimum settings can be realized with simple operations 518 for use with leak detection or liquid detection fiber only easy to operate with individual / collective teaching mode easy ma...

  • Page 56: Fx-301-F

    519 fx-301-f wiring- and labor-saving design allows side- by-side configuration for up to sixteen units easy operation with mode navi simple operation with easy access to advanced functions two switches with distinct functions only two switches, the large jog switch and the large mode key, are requi...

  • Page 57: Fx-301-F

    520 fx-301-f order guide fd-f7 series, ft-f9 series 12 to 24 v dc 10 % ripple p-p 10 % or less normal operation: 960 mw or less (current consumption 40 ma or less at 24 v supply voltage) eco mode: 600 mw or less (current consumption 25 ma or less at 24 v supply voltage) npn open-collector transistor...

  • Page 58: Fx-301-F

    521 fx-301-f symbols … d : reverse supply polarity protection diode z d : surge absorption zener diode tr : npn output transistor symbols … d : reverse supply polarity protection diode z d : surge absorption zener diode tr : pnp output transistor.

  • Page 59: Fx-301-F

    522 fx-301-f precautions for proper use mounting how to mount the amplifier cascading amplifiers • make sure that the power supply is off while cascading or removing the amplifiers. • make sure to check the allowable ambient temperature, as it depends on the number of amplifiers connected in cascade...

  • Page 60: Fx-301-F

    523 fx-301-f precautions for proper use individual teaching mode part description • the sensitivity selection function is set to the automatic sensitivity setting ( ) at the time of factory shipment. In case sensitivity selection setting is done, make sure to carry out ‘teaching’ after the sensitivi...

  • Page 61: Fx-301-F

    524 fx-301-f precautions for proper use press mode key to light up mode indicator / adj (yellow). Turn jog switch to the ‘ ’ side, to increase the threshold value. Turn jog switch to the ‘ ’ side, to decrease the threshold value. When jog switch is pressed, the changed threshold value blinks 3 times...

  • Page 62: Fx-301-F

    525 fx-301-f precautions for proper use press mode key to light up mode indicator / out (yellow). (present output state is displayed.) when jog switch is turned to the ‘ ’ side or ‘ ’ side, the output is compulsor y changed to on or off. Since the emitting element of the amplifier blinks, it is poss...

  • Page 63: Fx-301-F

    526 fx-301-f precautions for proper use no / nc selection function [liquid (f9) mode only] • the no / nc selection can be done by pressing the jog switch for 3 sec., or more, when liquid (f9) mode ( ) has been set and mode indicator / disp (yellow) lights up. In case of leak (f7) mode ( ), the displ...

  • Page 64: Fx-301-F

    527 fx-301-f.

  • Page 65: Fx-305

    Fx-305 digital fiber sensor four-chemical emitting element double coupling lens apc circuit n ew a dvanced sensor with v isible i ndicator digital fiber sensor with 2 independent outputs 122 series industry first! Light-emitting amount selection function stable sensing over long and short periods if...

  • Page 66: Fx-305

    123 fx-305 specifications i/o circuit dimensions (unit: mm in ) amplifier fx-305 fx-305p 2.5 0.098 digital display (red) jog switch mode key 0.7 0.028 output 1 operation indicator (orange) output 2 operation indicator (orange) 8.3 0.327 27.8 1.094 7 0.276 36.5 1.437 64.5 2.539 communication window 1...