13
ERROR INDICATION
●
In case of errors, attempt the following measures.
Display
Error description
Measures
EEPROM writing error
Contact our office.
The load has short-circuited and excess
current is flowing.
Turn off the power, then check the load.
Communication error
(Disconnection, connection failure, etc.)
Check the wiring before using the setting copy function.
14
SPECIFICATIONS
Type
Standard
Long sensing range
NPN output
FX-101
FX-101-CC2
FX-102
FX-102-CC2
Item
PNP output
FX-101P
FX-101P-CC2
FX-102P
FX-102P-CC2
Supply voltage
12 to 24V DC±10% Ripple P-P 10% or less (within the rated range)
Power consumption
Normal operation: 720mW or less (Current consumption 30mA or less at 24V supply voltage)
ECO mode: 600mW or less (Current consumption 25mA or less at 24V supply voltage)
Output
NPN open-collector transistor
· Maximum sink current: 100mA
· Applied voltage: 30V DC or less
(between output and 0V)
· Residual voltage: 1.5V or less
(at 100mA sink current)
PNP open-collector transistor
· Maximum source current: 100mA
· Applied voltage: 30V DC or less
(between output and +V)
· Residual voltage: 1.5V or less
(at 100mA source current)
Output operation
Light-ON or Dark-ON, selectable
Short-circuit protection
Incorporated
External input
NPN non-contact input
•
Signal condition
High: +8V to +V DC or Open
Low: 0 to +2V DC
(Source current 0.5mA or less)
• Input impedance: Approx. 10kΩ
PNP non-contact input
•
Signal condition
High: +4V to +V DC
(Sink current 0.5 to 3mA or less)
Low: 0 to +0.6V DC or Open
• Input impedance: Approx. 10kΩ
Response time
Emission frequency 0: 250μs or less
Emission frequency 1: 450μs or less
Emission frequency 2: 500μs or less
Emission frequency 3: 600μs or less
Emission frequency 1: 2.5ms or less
Emission frequency 2: 2.8ms or less
Emission frequency 3: 3.2ms or less
Emission frequency 4: 5.0ms or less
Ambient temperature
-10 to +55˚C (No dew condensation or icing allowed) (Note 2), Storage: -20 to +70˚C
Ambient humidity
35 to 85% RH, Storage: 35 to 85% RH
Emitting element
Red LED (peak wavelength = 632nm)
Material
Enclosure and the cover: Polycarbonate, Fiber lock lever: PBT
Weight
Approx. 15g (Main body only)
Accessory
CN-14A-C2
(Cable with connector, 2m long) (
-CC2
type only): 1pc.
Notes: 1) Cable with connector
CN-14A-C2
is not enclosed with models that have no suffix “
-CC2
” with the model Nos.
Make sure to use the optional cable with connector
CN-14A-C
□, or a connector (contact: SPHD-001T-P0.5,
housing: PAP-04V-S) manufactured by JST Mfg. Co., Ltd.
2) When using the products in parallel, the ambient temperature is as follows.
4 to 7 units: -10 to +50˚C, 8 to 16 units: -10 to +45˚C
15
CAUTIONS
●
This product has been developed / produced for industrial use only.
●
Make sure that the power supply is off while wiring.
● Take care that if a voltage exceeding the rated range is applied, or if an AC power
supply is directly connected, the product may get burnt or damaged.
●
Take care that short-circuit of the load or wrong wiring may burn or damage the product.
●
Do not run the wires together with high-voltage lines or power lines or put them in
the same raceway. This can cause malfunction due to induction.
●
Verify that the supply voltage variation is within the rating.
●
If power is supplied from a commercial switching regulator, ensure that the frame
ground (F.G.) terminal of the power supply is connected to an actual ground.
●
In case noise generating equipment (switching regulator, inverter motor, etc.) is
used in the vicinity of this product, connect the frame ground (F.G.) terminal of the
equipment to an actual ground.
●
Do not use during the initial transient time (0.5 sec.) after the power supply is switched on.
● Extension up to total 100m is possible with 0.3mm
2
, or more, cable. However, in
order to reduce noise, make the wiring as short as possible.
●
Make sure that stress by forcible bend or pulling is not applied to the sensor cable joint.
● Take care that the product is not directly exposed to fluorescent lamp from a rapid-starter lamp,
a high frequency lighting device or sunlight etc., as it may affect the sensing performance.
●
This product is suitable for indoor use only.
●
Avoid dust, dirt, and steam.
●
Take care that the product does not come in contact with oil, grease, organic sol-
vents, such as thinner, etc., strong acid or alkaline.
● This product cannot be used in an environment containing inflammable or explosive gases.
●
Never disassemble or modify the product.
●
EEPROM is adopted to this product. It is not possible to conduct teaching 100 thou-
sand times or more, because of the EEPROM’s lifetime.
16
APPLICABLE STANDARD/REGULATIONS
●
This product complies with the following standards / regulations.
EMC Directive 2004/108/EC
ANSI/UL 60947-5-2, CAN/CSA C22.2 No.14
●
Caution about UL recognition
In case requiring conformity of UL listing mark or C-UL listing mark,
use class 2 power supply unit.
●
Contact for CE
Panasonic Electric Works Europe AG
Rudolf-Diesel-Ring 2, D-83607 Holzkirchen, Germany
Panasonic Marketing Europe GmbH Panasonic Testing Center
Winsbergring 15, 22525 Hamburg,Germany
1.
Turn on the master side amplifier and the slave side amplifier at the same time. (Note)
2.
“
” is shown on the green digital display of the master side amplifier and 4-digit
code is shown on the red digital display of it, then the copying starts.
3.
When the copying is completed,
“
”
is shown on the green digital display of the
slave side amplifier, while the 4-digit code (the same code as the master side am
-
plifier) is shown on the red digital display of it.
4.
Turn off the power of the master side amplifier and the slave side amplifier and dis
-
connect the wire.
*
If copying the settings to another amplifier repeatedly, follow the steps
3
to
7
.
Note: Take care that if the power is not turned on at the same time, the setting contents may not be copied.
To cancel the setting copy mode of the master side amplifier
1.
While the slave side amplifier is disconnected, turn on the power of the master side
amplifier.
2.
Press MODE key for approx. 2 sec.
11
QUICK SETTING FUNCTION
●
Simply by selecting a setting number, output operation, emission amount, timer,
and emission frequency can be set.
●
For the setting numbers, refer to
. ● Make sure to return to RUN mode before turning OFF the power. If the power is turned OFF while setting, the changed contents have not been set. Press for 2 sec. (Quick setting) : Select a quick setting number (Note 1) (Emission frequency setting) (Note 1) : Select emission frequency AUTO Notes: 1) Cancellation is possible when pressing MODE key for 2 sec. or more before finalizing, then returns to RUN mode. 2) When the present setting is out of the quick setting range, “ ” is shown. When “ ” is selected, the set content is not changed. No. Output operation Emission amount setting Timer -00- D-ON Level 3 non -01- D-ON Level 2 non -02- D-ON Level 3 ofd 10ms -03- D-ON Level 2 ofd 10ms -04- D-ON Level 3 ofd 40ms -05- D-ON Level 2 ofd 40ms -06- D-ON Level 3 ond 10ms -07- D-ON Level 2 ond 10ms -08- D-ON Level 3 ond 40ms -09- D-ON Level 2 ond 40ms No. Output operation Emission amount setting Timer -10- L-ON Level 2 ond 40ms -11- L-ON Level 3 ond 40ms -12- L-ON Level 2 ond 10ms -13- L-ON Level 3 ond 10ms -14- L-ON Level 2 ofd 40ms -15- L-ON Level 3 ofd 40ms -16- L-ON Level 2 ofd 10ms -17- L-ON Level 3 ofd 10ms -18- L-ON Level 2 non -19- L-ON Level 3 non 12 CODE SETTING FUNCTION ● By selecting codes arbitrarily, output operation, timer, emission amount, emission fre- quency, ECO, external input, and shift amount can be set. ● For the codes, refer to ● Make sure to return to RUN mode before turning OFF the power. If the power is turned OFF while setting, the changed contents have not been set. 1 2 4 3 Press for 4 sec. (Note 1) (Code setting) (Note 2) (Note 3) : After finalizing, the digit shifts : Select codes (Note 4) AUTO Notes: 1) Although the quick setting function appears 2 sec. after the set value UP key and set value DOWN key are pressed, keep pressing the key. 2) Cancellation is possible when MODE key is pressed for 2 sec. or more before the digit blinks, then returns to RUN mode. 3) Cancellation of set value is possible when MODE key is pressed for 2 sec. or more while the digit is blinking. 4) When the fourth digit is determined, the settings are reflected. Code 1st digit 2nd digit 3rd digit 4th digit Output operation Timer (Note 5) Emission amount setting Emission frequency ECO External input Shift (Note 5) FX-101 □ FX-102 □ 0 D-on non Level 3 0 1 OFF Emission halt 5% 1 ond 10ms 1 2 Limit teaching [+] 10% 2 ond 40ms 2 3 Limit teaching [-] 15% 3 ofd 10ms 3 4 Full-auto teaching 20% 4 ofd 40ms Level 2 0 1 ECO 25% 5 L-on non 1 2 ON Emission halt 30% 6 ond 10ms 2 3 Limit teaching [+] 35% 7 ond 40ms 3 4 Limit teaching [-] 40% 8 ofd 10ms Level 1 0 1 Full-auto teaching 45% 9 ofd 40ms 1 2 ECO 50% A 2 3 OFF 2-level teaching b 3 4 Incident light intensity test c Auto 0 1 ON 2-level teaching d 1 2 Incident light intensity test E 2 3 F 3 4 Notes: 5) When the present setting is out of the code setting range, “–” is shown. When “–” is selected, the set content of the digit is not changed. 6) The factory setting is “ .” Model No. (Note1) http://panasonic.net/id/pidsx/global © Panasonic Industrial Devices SUNX Co., Ltd. 2012 Overseas Sales Division (Head Office) 2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan Phone: +81-568-33-7861 FAX: +81-568-33-8591 About our sale network, please visit our website. PRINTED IN CHINA
.