Panasonic KX-NS8188 Installation Manual

Manual is about: E1 Trunk Adaptor/PRI Adaptor

Summary of KX-NS8188

  • Page 1

    Installation manual e1 trunk adaptor/pri adaptor thank you for purchasing this panasonic product. Please read this manual carefully before using this product and save this manual for future use. Compatible pbx: kx-ns1000 pcmpr software file version 002.00000 or later model no. Kx-ns8188 kx-ns8290

  • Page 2: Introduction

    Introduction this installation manual is designed to serve as an overall technical reference for the kx-ns8188 e1 trunk adaptor/kx-ns8290 pri adaptor (trunk adaptor) for kx-ns1000. A trunk adaptor provides an e1/pri trunk interface to the kx-ns1000 and enables flexible trunk configuration. This manu...

  • Page 3: Table of Contents

    Table of contents 1 safety precautions ...................................................................................5 1.1 for your safety .................................................................................................................6 1.2 important safety instructions ..........

  • Page 4

    4 installation manual table of contents.

  • Page 5: Section  1

    Section 1 safety precautions this section provides important information intended to prevent personal injury and property damage. Installation manual 5.

  • Page 6: 1.1  For Your Safety

    1.1 for your safety to prevent personal injury and/or damage to property, be sure to observe the following safety precautions. The following symbols classify and describe the level of hazard and injury caused when this unit is operated or handled improperly. Warning this notice means that misuse cou...

  • Page 7: Warning

    Warning • do not install the system in the following locations: – areas where shocks or vibrations are frequent or strong. Such activity may lead to the product falling over and causing injury, or may impair the product’s performance. – areas with high amounts of dust. High amounts of dust can lead ...

  • Page 8

    • disconnect the trunk adaptor from the ac outlet and disconnect the lan cable if the trunk adaptor emits smoke, an abnormal smell, or makes unusual noise. These conditions can cause fire or electric shock. Confirm that smoke has stopped and contact an authorised service centre. • clean the ac plug ...

  • Page 9: Caution

    Caution • do not install the system in the following locations: – in direct sunlight and hot, cold, or humid places. (temperature range: 0 °c to 40 °c) – areas where sulphuric gases may be present, such as near thermal springs. – near devices that generate high frequencies, such as sewing machines o...

  • Page 10

    • unplug the system from its power source when wiring, and plug the system back in only after all wiring is completed. • use cables that are fire-resistant or fireproof. • make sure the cables are securely fastened to the wall. • the ac adaptor is used as the main disconnect device. Ensure that the ...

  • Page 11

    Notice safety requirements • before connecting the trunk adaptor, confirm that the trunk adaptor supports the intended operating environment. • if the trunk adaptor does not operate properly, disconnect the ac adaptor cord and lan cable, then connect again. • the trunk adaptor may not operate in the...

  • Page 12: Save These Instructions

    1.2 important safety instructions when using your telephone equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following: • do not use the product near water, for example, near a bathtub, wash bowl, kitchen si...

  • Page 13: 1.3  Precautions

    1.3 precautions for users in the european union only information for users on collection and disposal of old equipment and used batteries these symbols on the products, packaging, and/or accompanying documents mean that used electrical and electronic products and batteries should not be mixed with g...

  • Page 14

    Company because the telephone numbers include the toll access digit and area code digit. A toll charge may be incurred. Please check with the toll carrier concerned. • applicable only to telecom customers who have automatic access to other carriers for toll calls when calling back a number from the ...

  • Page 15: 1.4  Data Security

    1.4 data security in order to use the trunk adaptor safely and correctly, the security requirements below must be observed. Failure to do so may result in loss, leakage, falsification or theft of user information. What is user information? User information is defined as system data and error data in...

  • Page 16: 1.5  Additional Information

    1.5 additional information for users in canada only this product meets the applicable industry canada technical specifications. This class a digital apparatus complies with canadian ices-003. Notice attachment of non-ic certified/registered equipment is illegal in some areas of canada. Please consul...

  • Page 17: Section  2

    Section 2 system outline this section provides general information on the trunk adaptor, including the system capacity and specifications. Installation manual 17.

  • Page 18: 2.1.1  Model Line-Up

    2.1 basic system construction 2.1.1 model line-up the following table shows the different types of trunk adaptor. Model no. Type kx-ns8188x e1 trunk adaptor kx-ns8290ce pri adaptor (30 ch) kx-ns8290x pri adaptor (23 ch) 2.1.2 optional equipment ac adaptor • kx-a239al (pqlv206al) • kx-a239bx (pqlv206...

  • Page 19

    Note you can connect the trunk adaptor to the pbx without the need for activation keys. Pure ip-pbx (kx-ns1000) sip phone (kx-ut series) ip-pt (kx-nt series) pc (web maintenance console) telephone company lan e1/pri (23 ch/30 ch) e1 trunk adaptor (kx-ns8188)/ pri adaptor (kx-ns8290) dsu* 1 *1 dsu: d...

  • Page 20: 2.1.4  Service Feature

    2.1.4 service feature 2.1.4.1 e1 gateway the trunk adaptor for e1 trunks allows a kx-ns1000 to connect to an e1 line as it converts data between the sip and e1 protocols. Dsu kx-ns1000 pstn lan e1 trunk adaptor ip network e1 line e1 line sip sip the following table shows features supported by the e1...

  • Page 21

    The trunk adaptor for pri trunks—private mode allows a kx-ns1000 to connect to a pri qsig network as it converts data between the h.323 and isdn qsig protocols. Kx-ns1000 kx-ns1000 pstn lan pri adaptor ip network pri line pri line sip sip public mode private network lan pri adaptor ip network isdn q...

  • Page 22: 2.2  Specifications

    2.2 specifications 2.2.1 general description cpu arm11 450 mhz network port 1 port (rj45 connector) ieee802.3 10/100base-tx auto negotiation, auto mdi/mdix status led: link, 100 line interface 1 port (rj45 connector) framer e1/t1 framer nt/te mode e1/pri public mode: te qsig master: te qsig slave: n...

  • Page 23: Section  3

    Section 3 installation this section describes the procedures to connect the trunk adaptor to the pbx. Installation manual 23.

  • Page 24: 3.1  Before Installation

    3.1 before installation please read the following notes concerning installation and connection before installing the trunk adaptor. Be sure to comply with all applicable laws, regulations, and guidelines. Notice panasonic assumes no responsibility for injuries or property damage resulting from failu...

  • Page 25: 3.2.1  Unpacking

    3.2 installation of the trunk adaptor 3.2.1 unpacking unpack the box and check the items below: main unit ´ 1 screw ´ 2 washer ´ 2 notice after unpacking the product, dispose of the packing materials appropriately. 3.2.2 names and locations back side front side when wall mounted front side a b c de ...

  • Page 26: 3.2.3  Led Indications

    No. Name description f lan led (100) ethernet data transmission speed indication g line port e1 line interface (kx-ns8188x) pri23 line interface (kx-ns8290x) pri30 line interface (kx-ns8290ce) h initialize system initialise switch 3.2.3 led indications indication status colour system power off off a...

  • Page 27: 3.2.4  Types of Connectors

    3.2.4 types of connectors please refer to "types of connectors" in the installation manual of the kx-ns1000 pbx. The connector type for the trunk adaptor is rj45. 3.2.5 placing the trunk adaptor on a desktop when placing the trunk adaptor on a desktop, make sure to follow these instructions. Warning...

  • Page 28

    • only use the wall-mounting equipment (screws, washers) included with the trunk adaptor. • be careful not to drop any components. Dropping components may damage them or cause an injury. • when the trunk adaptor is no longer in use, make sure to detach it from the wall. Caution • make sure that the ...

  • Page 29

    3. Hook the trunk adaptor on the screw heads in any of the following 4 directions. Washer drive the screw to this point. A b c d hook this part onto both screws. Installation manual 29 3.2.6 wall mounting.

  • Page 30: 3.2.7  Wiring Requirement

    Reference for wall mounting please copy this page and use as a reference for wall mounting. Install a screw here. Install a screw here. 83 mm note make sure to set the print size to correspond with the size of this page. If the dimension of the paper output still deviates slightly from the measureme...

  • Page 31

    3.3 starting the trunk adaptor 3.3.1 installation procedure and connection diagrams this section describes the installation procedure for connecting the trunk adaptor and kx-ns1000 pbx. Requirements power supply: ac adaptor trunk adaptor ip address: static ip address warning when installing or testi...

  • Page 32

    7. Shutdown the trunk adaptor through web maintenance console and disconnect the ac adaptor from the trunk adaptor. 8. Change the trunk adaptor’s lan cable connection from the pc to the switching hub, and then connect the ac adaptor to the trunk adaptor again. 9. Confirm the running status of the tr...

  • Page 33: Section  4

    Section 4 programming with web maintenance console this section describes the installation procedure, structure, and functions of web maintenance console for programming the trunk adaptor. Installation manual 33.

  • Page 34

    4.1 overview of web maintenance console web maintenance console of the trunk adaptor is designed to serve as an overall system programming reference for the trunk adaptor. You can programme and control the trunk adaptor over an ip network using web maintenance console. This section describes program...

  • Page 35

    Setting item description value range software version displays the trunk adaptor’s software version. 000.000.00–999.999.99 installation manual 35 4.1 overview of web maintenance console.

  • Page 36: 4.2  Pc Connection

    4.2 pc connection you can connect a pc to the trunk adaptor either directly or over a lan using the appropriate method for the port being used. Direct connection to lan port to ac adaptor lan port system initialise switch notice when connecting a pc to the trunk adaptor, a fixed ip address must be a...

  • Page 37

    Connection via virtual private network (vpn) to ac adaptor switching hub lan pc router router vpn system initialise switch lan port notice to access the trunk adaptor via vpn, the pc must be in the same vpn. Connection via internet to ac adaptor switching hub lan system initialise switch lan port pc...

  • Page 38

    4.3 starting web maintenance console system requirements required operating system • microsoft ® windows ® xp, windows vista ® business, or windows 7 professional operating system recommended display settings • screen resolution: xga (1024 ´ 768) • dpi setting: normal size (96 dpi) supported browser...

  • Page 39: 4.4.1  Easy Setup Wizard

    4.4 programming the trunk adaptor 4.4.1 easy setup wizard in the easy setup wizard, you will set up the mandatory settings required for the trunk adaptor. When you log in to web maintenance console for a trunk adaptor that is in its initialised, factory default state, the easy setup wizard will laun...

  • Page 40: 4.4.2  Setting List

    D. Enter the preferred and alternative dns ip addresses *1 . E. Click next. *1 valid ip address range: "1.0.0.0" to "223.255.255.255" *2 valid subnet mask address range: "0–255.0–255.0–255.0–255" (except "0.0.0.0" and "255.255.255.255") 5. In sntp / daylight saving, enter information for automatic t...

  • Page 41

    Category setting item value range default value incoming call inter-digit timer - ddi/did 0–30 s 5 s incoming call inter-digit timer - tie 3–30 s 5 s pri23/pri30 port property—main port 1 – port type co (fixed when network type is set to public) co qsig-slave, qsig-master (when network type is set t...

  • Page 42

    Category setting item value range default value pri23/pri30 port property—network configuration port 1 – port type co (fixed when network type is set to public) co qsig-slave, qsig-master (when network type is set to private) set during "4.4.1 easy setup wizard" connection ins, ous, fault – network ...

  • Page 43

    Category setting item value range default value called party number— type of number (private) unknown, international, national, network, subscriber unknown pri23/pri30 port property—system option port 1 – port type co (fixed when network type is set to public) co qsig-slave, qsig-master (when networ...

  • Page 44

    Category setting item value range default value seizure ack wait timer 0.5 × n (n=1–20) s 2.5 s liu send option mode-1 – mode-8 mode-8 liu receive option automatic, 6 db, 12 db, 18 db, 24 db automatic rai signal detection mode type1, type2 type1 dtmf tone—dtmf inter-digit pause 16 × n (n=4–15) ms 11...

  • Page 45

    Category setting item value range default value e1 card property— mfc-r2 setting1 ani service—mode none, incoming call only, outgoing call only, both calls none ani service—ani max. Digits none, 1–16 none mfc-r2 timer— forward 1–30 s 15 s mfc-r2 timer— backward 1–30 s 15 s mfc-r2 timer— disappearanc...

  • Page 46

    Category setting item value range default value mfc-r2 group-1[*][#]— e1 mfc-r2 group1[*] code 11–15 11 mfc-r2 group-1[*][#]— e1 mfc-r2 group1[#] code 11–15 12 e1 card property— mfc-r2 setting2 group-a code assignment—address complete 1–15 3 group-a code assignment—ani request 1–15 5 group-a code as...

  • Page 47

    Category setting item value range default value group-b code assignment— unallocated undefined, 1–15 3 group-b code assignment— congestion undefined, 1–15 4 group-b code assignment— out-of-service undefined, 1–15 4 group-b code assignment—no billing undefined, 1–15 undefined group-b code assignment—...

  • Page 48

    • receive digits • cpc detection time-out, in • dtmf width • ringback tone to outside caller • answer wait timer (*60s) • pause time • flash time • disconnect time configuration—ip interface category setting item value range default value voip setting—codec voice activity detection for g.711 disable...

  • Page 49

    Category setting item value range default value voip setting—dsp option2 jitter compensation operation for g.711 disable, enable enable jitter compensation operation for g.711 fax disable, enable enable jitter compensation operation for g.729a disable, enable enable jitter buffer delay min. For voic...

  • Page 50

    Category setting item value range default value gw name(secondary) max. 20 characters not stored gw ip address(secondary) 1.0.0.0– 223.255.255.255 – protocol tcp, udp tcp progress tone send mode external, internal internal system property— ipgw call signalling model direct, gatekeeper direct gatekee...

  • Page 51

    Category setting item value range default value t310 0–3000 1000 t313 0–600 60 t316 0–3000 0 t318 0–600 0 t319 0–600 0 t322 0–600 40 t3d3 0–3000 50 t3d9 0–3000 200 ip-gw card property— gk settings no. 1–48 – destination number (30 digits) max. 30 digits not stored device name max. 20 characters not ...

  • Page 52

    Sip port property copy you can copy the authentication password setting value from one port to other ports by clicking the button on the sip port property screen and configuring the sip port property copy screen. This feature is available only when the activation key mode setting is set to yes. Conf...

  • Page 53

    Configuration—maintenance category setting item value range default value system settings installer password 4–16 digits 1234 web-mc language english (us), english (uk), french, german, italian, spanish, russian, others english (uk) sip authentication id plan 1–3 digits 4 network service—system cont...

  • Page 54

    Category setting item value range default value ip address/ports— reference assigned ip address— ip address 1.0.0.0– 223.255.255.255 – assigned ip address— mac address 00:00:00:00:00:00– ff:ff:ff:ff:ff:ff – assigned ip address— subnet mask 0–255.0–255.0–255.0– 255 (except 0.0.0.0 and 255.255.255.255...

  • Page 55

    Category setting item value range default value automatic logout timer (min) 5, 10, 30, 60 × n (n=1– 24) 60 network service—client feature category setting item value range default value ftp connection 1–5— connection name max. 64 characters – connection 1–5—ip address/name ip address, name ip addre...

  • Page 56

    Network service—other category setting item value range default value security icmp echo reply— lan port enable, disable enable icmp echo reply— log output enable, disable disable ssl/tls—encryption suite aes256-sha, des-cbc3-sha, aes128-sha, des-cbc-sha des-cbc3-sha system control—program update ca...

  • Page 57

    File—file delete deletes files stored in the trunk adaptor. Log—error log collects and displays system error information. Click log information to download the error log to the connected pc. Log—syslog displays a log of system events. Monitor/trace—isdn/qsig protocol trace displays protocol trace da...

  • Page 58

    4.5 programming for the kx-ns1000 the following tables show the settings (items, value ranges, and defaults etc.) that you can configure using the kx-ns1000 web maintenance console. Ip-gw pbx configuration—[1-1] configuration—slot—virtual—v-ipgw16 port property category setting item value range sett...

  • Page 59

    Category setting item value range setting value sip account / user name—from 100–99999 set the sip account / user name start number for the trunk adaptor referring to the sip authentication id (sip port property) of the trunk adaptor’s first port. The default start number is 401. Port property - vir...

  • Page 60

    60 installation manual 4.5 programming for the kx-ns1000

  • Page 61: Section  5

    Section 5 troubleshooting this section provides information on the trunk adaptor troubleshooting. Installation manual 61.

  • Page 62: 5.1  Installation

    5.1 installation problem probable cause solution the system led of the trunk adaptor is lit or flashing red. A major system error has occurred in the trunk adaptor. Turn the trunk adaptor off and then back on. If the problem is not resolved, consult your dealer. Cannot set the ip address or subnet m...

  • Page 63: Index

    Index installation manual 63.

  • Page 64

    C connection diagram, system 18 connector types 27 d ddi/did, programming for the kx-ns1000 59 e e1 gateway 20 easy setup wizard 39 i installation precautions 24 ip-gw, programming for the kx-ns1000 58 n names and locations 25 p password security 38 pri gateway 20 programming for the kx-ns1000, ddi/...

  • Page 65

    The kx-ns8290ce is designed to interwork with the pan-european integrated services digital network (isdn) using isdn primary rate access. Panasonic system networks co., ltd. Declares that the kx-ns8290ce is in compliance with the essential requirements and other relevant provisions of radio & teleco...

  • Page 66

    1-62, 4-chome, minoshima, hakata-ku, fukuoka 812-8531, japan copyright: this material is copyrighted by panasonic system networks co., ltd., and may be reproduced for internal use only. All other reproduction, in whole or in part, is prohibited without the written consent of panasonic system network...