Panasonic SU-MED640E Operating Instructions Manual

Manual is about: 64-CHANNEL

Summary of SU-MED640E

  • Page 1

    64-channel integrated amplifier operating instructions p/n: su-med640e panasonic.

  • Page 2

    Caution for ac main lead for your safety, please read the following text carefully this product is equipped with 2 types of ac main cable. One is for continental europe, etc. And the other one is only for uk. Appropriate main cable must be used in each local area, since the other type of main cable ...

  • Page 3

    3 safety precautions before using this unit please read these operating instructions carefully. Take special care to follow the warnings indicated on the unit itself as well as the safety suggestions listed below. Keep these precau- tions handy for future reference. The unit may be used only in the ...

  • Page 4

    4 service - never attempt to repair, disassemble or modify the unit if there seems to be a problem. A serious electric shock could result if you ignore this precautionary measure. - if a problem occurs during operation (smoke is detected, etc.) contact your dealer immediately. - disconnect the power...

  • Page 5

    5 components and their functions front panel (1) power to turn the amplifier on and off. Caution: do not turn on the power with a "mini-plug" connected on the output terminal of the internal stimulators (#2, 3, 4 & 5). This may cause damage to the microelectrode(s) on the probe. (2) output int(v) [c...

  • Page 6

    6 back panel (13) input to connect to the med probe, through the med-co3 connector, to the amplifier. (14) output(1-32ch) to connect the output of channels 1-32 to the to the first a/d board in the computer. (15) output(33-64ch) to connect the output of channels 33-64 to the to the second a/d board ...

  • Page 7

    7 connection to other components usage of internal stimulus amplifier (components and cables indicated with dashed lines are not included) med connector a/d board cables (ni sh-100100) connector cable (included) a/d board in pc (ni pci-6071e) a/d board in pc (ni pci-6071e).

  • Page 8

    8 using the med64 amplifier with external devices (stimulator, isolator, oscilloscope). Caution: do not connect med64 mini-plugs on the internal stimulator outputs (ch1 or ch2). (components and cables indicated with dashed lines are not included.) external stimulator external isolator external stimu...

  • Page 9

    9 precautions during use always, turn on the amplifier power before starting up the software. The software sends information to the amplifier that is necessary for initialization of stimuli and the recorded data. Failure to do so (i.E. Turn- ing on power to the amplifier after the software starts up...

  • Page 10

    10 specifications specifications may not be satisfied depending upon the type of computer or operating environments used. Only for use in animal studies research. Specifications and external appearance are subject to change without notice. October, 2005 [recording unit] channels 64 input impedance >...

  • Page 11

    Rqt5390-b matsushita electric industrial co., ltd. 1-4 matsuo-cho, kadoma, osaka 571-8505 japan.