Panasonic U-10MX4XPQ Installation Manual

Other manuals for U-10MX4XPQ: Operation Manual
Manual is about: URBAN MULTI AIR CONDITIONER

Summary of U-10MX4XPQ

  • Page 1

    Installation manual urban multi air conditioner english installationsanleitung urban multi klimaanlage deutsch manuel d'installation climatiseur urban multi français montagehandleiding urban multi airconditioner nederlands manual de instalación acondicionador de aire urban multi español manuale d'in...

  • Page 2

    7 3 5 2 b a c d a c b d a e b d e a c b d ≥ 1500 1 3 5 4 2 2 (mm) 6 3 ≥ 1000 ≥ 1000 ≥ 1000 ≥ 1500 ≥ 1500 ≥ 1500 722-737 ≥ 67 ≥ 67 765 67 67 a b 1 2 4 5 6 7 3 10 11 1 1 2 4 5 3 5 3 3 2 1 5 3 3 1 3 2 8 6 4 8 1 3 2 8 6 4 8 1 3 2 7 8 9 8 10 11 8 8 8 5 5 9 1 3 2 7 8 8 8 5 1 a b 2 1 4 8 ≥ 100 ≥ 100 a b c ...

  • Page 3

    21 18 19 20 23 24 25 22 l 1 l 2 l 3 n 1 3 4 2 13 15 14 16 a b ± 3 0 ° 1 1 17 1 2 3 4 5 a b c a b c f 1 f 2 f 1 f 2 q 1 q 2 a b c f1 f1 f2 f2 q1 q2 f1 f2 f1 f2 f1 f2 f1 f2 f1 f2 f1 f2 4 5 1 2 6 7 c/h selector to in/d unit to out/d unit to multi unit a1p 3 a b c f1 f2 f1 f2 q1 q2 q1 q2 a1p 4 4 5 6 2 1...

  • Page 4

    Installation manual 1 u-5~18mx4xpq urban multi air conditioner 4pw28163-1 c ontents page 1. Introduction................................................................................ 1 1.1. Combination................................................................................. 1 1.2. Standard...

  • Page 5

    U-5~18mx4xpq urban multi air conditioner 4pw28163-1 installation manual 2 ■ total capacity/quantity of indoor units 1.2. Standard supplied accessories see location 1 in figure 24 for reference to where following accessories are supplied with the unit. See location 2 in figure 24 for reference to whe...

  • Page 6

    Installation manual 3 u-5~18mx4xpq urban multi air conditioner 4pw28163-1 3. S election of location this is a class a product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. This unit, both indoor and outdoor, is ...

  • Page 7

    U-5~18mx4xpq urban multi air conditioner 4pw28163-1 installation manual 4 4. I nspecting and handling the unit at delivery, the package should be checked and any damage should be reported immediately to the carrier claims agent. When handling the unit, take into account the following: 1 fragile, han...

  • Page 8

    Installation manual 5 u-5~18mx4xpq urban multi air conditioner 4pw28163-1 6.1. Installation tools make sure to use installation tools (gauge manifold charge hose, etc.) that are exclusively used for r410a installations to withstand the pressure and to prevent foreign materials (e.G. Mineral oils suc...

  • Page 9

    U-5~18mx4xpq urban multi air conditioner 4pw28163-1 installation manual 6 2 removing the pinched piping when connecting refrigerant piping to the outdoor unit, first remove the pinched piping. Removing of the pinched piping must be carried out according to the following procedure: 1. Connect a charg...

  • Page 10

    Installation manual 7 u-5~18mx4xpq urban multi air conditioner 4pw28163-1 prohibited patterns : change to pattern 1 or 2. ■ to avoid the risk of oil retention to the outmost outdoor unit, always connect the stop valve and the piping between outdoor units as shown in the 4 correct possibilities of th...

  • Page 11

    U-5~18mx4xpq urban multi air conditioner 4pw28163-1 installation manual 8 6.6. Example of connection example of connection (connection of 8 indoor units heat pump system) branc h with line branc h pipe branc h with line branc h pipe and header branc h pipe branc h with header branc h pipe one outdoo...

  • Page 12

    Installation manual 9 u-5~18mx4xpq urban multi air conditioner 4pw28163-1 pipe siz e selection f or an outdoor unit m ulti installation (u-20~54mx4), select the pipe siz e in accordance with the f ollo wing figure . A,b,c. Piping between outdoor unit and refrigerant branc h kit • choose from the f o...

  • Page 13

    U-5~18mx4xpq urban multi air conditioner 4pw28163-1 installation manual 10 7. L eak test and vacuum drying the units were checked for leaks by the manufacturer. After connecting the field piping, perform the following inspections. 1 preparations referring to figure 27, connect an oxygen tank, a cool...

  • Page 14

    Installation manual 11 u-5~18mx4xpq urban multi air conditioner 4pw28163-1 8.1. Internal wiring – parts table refer to the wiring diagram sticker on the unit. The abbreviations used are listed below: a1p~7p ..................Printed circuit board bs1~5 ....................Push button switch (mode, s...

  • Page 15

    U-5~18mx4xpq urban multi air conditioner 4pw28163-1 installation manual 12 8.3. Power circuit and cable requirements a power circuit (see table below) must be provided for connection of the unit. This circuit must be protected with the required safety devices, i.E. A main switch, a slow blow fuse on...

  • Page 16

    Installation manual 13 u-5~18mx4xpq urban multi air conditioner 4pw28163-1 8.5. System examples (see figure 15) 8.6. Leading power line and transmission line ■ be sure to let the power line and the transmission line pass through a conduit hole. ■ lead the power line from the upper hole on the left s...

  • Page 17

    U-5~18mx4xpq urban multi air conditioner 4pw28163-1 installation manual 14 fixing transmission wiring (see figure 23) inside switchbox outside unit sequential start the outdoor unit pc board (a1p) is factory set at "sequential start available". Setting the cool/heat operation 1 performing cool/heat ...

  • Page 18

    Installation manual 15 u-5~18mx4xpq urban multi air conditioner 4pw28163-1 8.9. Wiring example for wiring inside unit see figure 26. 9. P ipe insulation after finishing the leak test and vacuum drying, the piping must be insulated. Take into account the following points: ■ make sure to insulate the ...

  • Page 19

    U-5~18mx4xpq urban multi air conditioner 4pw28163-1 installation manual 16 11. C harging refrigerant the outdoor unit is factory charged, but depending on the length of the piping when installed, the outdoor unit may require additional charging. For charging the additional refrigerant follow the pro...

  • Page 20

    Installation manual 17 u-5~18mx4xpq urban multi air conditioner 4pw28163-1 11.4. Additional refrigerant charge there are two ways to charge refrigerant. Use the selected method following the described procedure below. ■ adding refrigerant using leak detection function. Refer to "1 adding refrigerant...

  • Page 21

    U-5~18mx4xpq urban multi air conditioner 4pw28163-1 installation manual 18 to speed up the proces of charging refrigerant for large systems, it is recommended to first manually charge a portion of the refrigerant first before performing automatic charging. 1 calculate how much refrigerant to be adde...

  • Page 22

    Installation manual 19 u-5~18mx4xpq urban multi air conditioner 4pw28163-1 8. Operation when the following led display is shown, open valve a and close the frontpanel. If the frontpanel is left open, the system can not operate properly during the refrigerant charging. * = the state of this led is no...

  • Page 23

    U-5~18mx4xpq urban multi air conditioner 4pw28163-1 installation manual 20 2 adding refrigerant without using leak detection function ■ charge with the outdoor unit at standstill 1. Calculate how much refrigerant to be added using the formula explained in the chapter "how to calculate the additional...

  • Page 24

    Installation manual 21 u-5~18mx4xpq urban multi air conditioner 4pw28163-1 ■ charging in cooling mode 6. Start up wait while the unit is preparing for charging in cooling mode. 7. Ready press the button once within 5 minutes. If the button is not pushed within 5 minutes, p2 will be displayed on the ...

  • Page 25

    U-5~18mx4xpq urban multi air conditioner 4pw28163-1 installation manual 22 5 final adjustment of the amount of refrigerant ■ when the unit displays an out of temperature range, the automatic charging of refrigerant can not be completed. ■ out of outdoor temperature range complete the charging of ref...

  • Page 26

    Installation manual 23 u-5~18mx4xpq urban multi air conditioner 4pw28163-1 12.2. Checks before initial start-up after the installation, check the following before switching on the circuit breaker: 1 the position of the switches that require an initial setting make sure that switches are set accordin...

  • Page 27

    U-5~18mx4xpq urban multi air conditioner 4pw28163-1 installation manual 24 check operation procedure 1 turn the power on for the outdoor unit and the indoor unit. Be sure to turn the power on at least 6 hours before operation inorder to have power running to the crank case heater. 2 make sure that t...

  • Page 28

    Installation manual 25 u-5~18mx4xpq urban multi air conditioner 4pw28163-1 4 push the button and the setting is defined. 5 when the button is pushed again, the operation starts according to the setting. Refer to the service manual for more details and for other settings. Confirmation of the set mode...

  • Page 29

    U-5~18mx4xpq urban multi air conditioner 4pw28163-1 installation manual 26 4 set the check operation (without initial refrigerant decision) following setting mode 2 in the field setting and perform the check operation. The system operates for ±30 minutes and automatically stops the check operation. ...

  • Page 30

    Installation manual 27 u-5~18mx4xpq urban multi air conditioner 4pw28163-1 13. S ervice mode operation vacuuming method at the first installation, this vacuuming is not required. It is required only for repair purposes. 1 when the unit is at standstill and under the setting mode 2, set the required ...

  • Page 31

    U-5~18mx4xpq urban multi air conditioner 4pw28163-1 installation manual 28 2 calculate the smallest room volume (m 3 ) in a case such as the following, calculate the volume of (a), (b) as a single room or as the smallest room. 3 calculating the refrigerant density using the results of the calculatio...

  • Page 32

    26 12 13 14 15 16 17 18 5 1 7 10 3 2 9 6 6 6 6 7 4 11 8 6 6 6 6 6 6 7 7 9 8 4 11 6 6 1 10 3 2 6 6 6 6 27 13 6 9 8 1 2 4 3 5 14 15 16 12 11 10 10 7 28 13 14 3 5 4 2 1 7 8 9 6 10 10 11 10 2 2 12 9 9 29 13 14 3 5 4 2 1 7 8 9 6 10 10 11 12 26 27 28 29.

  • Page 33

    4pw28163-1.