Polar Electro 7514-0050 Instruction Manual - Peak Hold Mode Operation
6
(System indicate)
Setting target torque
Peak hold/track mode
Set peak/track mode
Record no.
Clear record
Peak hold/track mode
Communication
(Exit)
Yes
Record value
Auto change
Recording
Apply torque
Apply torque
Current max. value
(Peak hold)
Released
Flashing
Buzzer
Buzzer
Green LED
Reached 90% of target torque
Red LED
Approaching target torque
Reached 90% of target torque
Reached target torque
START
PEAK HOLD MODE OPERATION
PEAK HOLD MODE RECORDED
VALUE REVIEW
((((((((
))))))))
((((((( )))))))
((…((… …))…)) ((…((… …)) …))
*Note 1
*Note 1
*Note 2
*Note 3
*Note 4, 5, 6
*Note 2
*Note 3
Note:
1. If
appears, it means the screw-
driver is overloaded. Overload = 110% of
maximum torque. Please contact your local
dealer for recalibration.
2. If
appears, that means the screw-
driver’s memory is full and the next value
record can not be written in. Please refer to
the “Peak hold mode recorded value review”
section to clear the memory records.
3. When reaching the setting target torque,
the green and red LED will be on at the same
time.
Note:
1. The ”Peak hold” mode recorded value review
can also be operated from ”Track” mode operation.
2. If you operate in the ”Peak hold” mode, the
display will show
. Please go to next step.
3. If the record is empty, it will show
.
4. This function is not supported on all models.
5. Communication mode is for uploading recorded
data to PC.
6. Communication mode is also for calibration of
the screwdriver.
Please contact your local dealer for information.
Long press
Press
Press
Press
(Give up)
Deleted
(Clear)
No