Protemp PT-125-OFR-A User's Manual & Operating Instructions - Operation: 70-Ss / 125-Ofr

Manual is about: KEROSENE RADIANT HEATER

Summary of PT-125-OFR-A

  • Page 1

    Consumer: read and save these instructions general hazard warning: read and understand all of the instructions in this manual before assembling, starting, or servicing the heater. Be sure to comply with the instructions and warnings provided with this heater. Failure to comply can result in fire or ...

  • Page 2: Warning

    © 2017, pinnacle climate technologies, inc. Kerosene radiant heater user’s manual never leave heater unattended while burning or while connected to a power source ® 1 massachusetts residents: massachusetts state law prohibits the use of this heater in any building which is used in whole or in part f...

  • Page 3: Warning

    © 2017, pinnacle climate technologies, inc. Kerosene radiant heater user’s manual never leave heater unattended while burning or while connected to a power source ® 2 always use only the electrical power (voltage and frequency) specified on the model plate of the heater. Always use only three-prong,...

  • Page 4: Features

    © 2017, pinnacle climate technologies, inc. Kerosene radiant heater user’s manual never leave heater unattended while burning or while connected to a power source ® 3 features fuel pressure gauge (behind removable cover) 70-ss 125-ofr º top safety guard radiant cone front safety guard radiant visors...

  • Page 5: Assembly Instructions

    © 2017, pinnacle climate technologies, inc. Kerosene radiant heater user’s manual never leave heater unattended while burning or while connected to a power source ® 4 assembly instructions 70-ss what’s in the box tools needed: - phillips head screw driver figure 1 figure 2 attach the handle while st...

  • Page 6: Assembly Instructions

    © 2017, pinnacle climate technologies, inc. Kerosene radiant heater user’s manual never leave heater unattended while burning or while connected to a power source ® assembly instructions 125-ofr what’s in the box safety guards (top, front) wheel frame 5 long screws (6) short screws (4) 8 mm nuts (6)...

  • Page 7: Operation: 70-Ss / 125-Ofr

    © 2017, pinnacle climate technologies, inc. Kerosene radiant heater user’s manual never leave heater unattended while burning or while connected to a power source ® operation: 70-ss / 125-ofr fueling the heater: kerosene for optimal performance of this heater, it is strongly suggested that kerosene ...

  • Page 8: Operation: 70-Ss / 125-Ofr

    © 2017, pinnacle climate technologies, inc. Kerosene radiant heater user’s manual never leave heater unattended while burning or while connected to a power source ® operation: 70-ss / 125-ofr starting the heater: (ignition) 1. Fill the tank with kerosene or other approved fuel until needle on fuel g...

  • Page 9: Maintenance: 70-Ss / 125-Ofr

    © 2017, pinnacle climate technologies, inc. Kerosene radiant heater user’s manual never leave heater unattended while burning or while connected to a power source ® maintenance: 70-ss / 125-ofr long term storage: 1. Unscrew the fuel cap. 2. Using an approved siphon, remove the kerosene or diesel. 3....

  • Page 10: Maintenance: 70-Ss / 125-Ofr

    © 2017, pinnacle climate technologies, inc. Kerosene radiant heater user’s manual never leave heater unattended while burning or while connected to a power source ® maintenance: 70-ss / 125-ofr service (continued): nozzles: nozzles should be cleaned or replaced at least once per heating season. Cont...

  • Page 11

    © 2017, pinnacle climate technologies, inc. Kerosene radiant heater user’s manual never leave heater unattended while burning or while connected to a power source ® 10 troubleshooting guide: 70-ss / 125-ofr problem possible cause solution heater fires, but shuts down after a short period of time. 1....

  • Page 12: Wiring Diagram

    © 2017, pinnacle climate technologies, inc. Kerosene radiant heater user’s manual never leave heater unattended while burning or while connected to a power source ® 125-ofr 11 wiring diagram ac 120v/60hz ac 250v 3.15a electric outlet 70-ss.

  • Page 13: Exploded View

    © 2017, pinnacle climate technologies, inc. Kerosene radiant heater user’s manual never leave heater unattended while burning or while connected to a power source ® exploded view 12 25 23 24 9 21 22 20 19 26 10 7 28 6 4 3 1 2 27 8 12 13 29 5 16 17 18 14 15 11 30 31 70-ss.

  • Page 14: Parts List: 70-Ss

    © 2017, pinnacle climate technologies, inc. Kerosene radiant heater user’s manual never leave heater unattended while burning or while connected to a power source ® 13 parts list: 70-ss item # description 70-ss 1 fuel filter 75-023-0285 2 fuel line 75-024-0510 3 fuel gauge 75-022-0200 4 fuel cap 70-...

  • Page 15: Exploded View

    © 2017, pinnacle climate technologies, inc. Kerosene radiant heater user’s manual never leave heater unattended while burning or while connected to a power source ® 1 2 4 3 5 6 7 8 9 10 11 12 13 14 15 16 17 18 24 20 22 21 30 23 26 19 34 27 29 42 31 31 32 25 28 exploded view 125-ofr 14.

  • Page 16: Parts List: 125-Ofr

    © 2017, pinnacle climate technologies, inc. Kerosene radiant heater user’s manual never leave heater unattended while burning or while connected to a power source ® parts list: 125-ofr 15 item # description 125-ofr 1 fuel filter 72-022-0100 2 fuel cap 72-006-0140 3 wheel 72-041-1400 4 axle 72-041-02...

  • Page 17: Limited Warranty

    © 2017, pinnacle climate technologies, inc. Kerosene radiant heater user’s manual never leave heater unattended while burning or while connected to a power source ® 16 limited warranty pinnacle climate technnologies, inc. Warrants this heater to the original retail purchaser only, to be free from de...

  • Page 18

    1 industrial blvd #101, sauk rapids, mn 56379 usa • toll free (800) 779-3267 fax: 320-251-2922 • web: www.Protemp.Us • email: info@pinnacleclimate.Com © 2017 pinnacle climate technologies, inc..