Protherm 60 Instructions For Use Manual - 5 Boiler Installation
Supplied By www.heating spares.co Tel. 0161 620 6677
18
221974A
5 Boiler Installation
Diagram 5.1
CONTROLS
COVER
FRONT
COVER
SHAKEPROOF
WASHER
9202
NUT
5.1 Boiler Preparation
Open the carton, check the items supplied against the boiler
pack contents list on the carton flap.
With the boiler still in in the bottom tray slide the controls cover
upwards and remove, see diagram 5.1.
Remove the front cover by undoing the wing nut, nut and
washer, lift the front cover off, see diagram 5.1.
Place controls cover and front cover to one side until required.
Fit suitable compression fittings to the required tappings on the
boiler.
Disconnect the air pressure tubes, see diagram 8.1.
Remove the blue and red electrical connections from the fan,
see diagram 8.1.
Remove the front right hand flue hood securing screw and
slacken off the front left hand one, see diagram 8.3.
Remove fan and flue hood assembly from boiler by drawing
assembly forward, place to one side until required.
5.2 Mounting the boiler
Lift the boiler into position ensuring first that the bottom of the
boiler is hooked on to the boiler mounting bracket and then
engage the two keyhole slots, located on top of the boiler, on to
the securing screws. Tighten the two securing screws, see
diagram 5.2
Note: Installations where the flue exits to the left of the boiler,
complete the water connections to the boiler before fitting the
flue.
From the fittings pack, place top turret gasket in position on
boiler flue opening, see diagram 5.3
Taking care not to damage the gasket, secure the top turret with
flue assembly to the boiler with four self-tap screws, see
diagram 5.3.
From the fittings pack, fit flue duct extension assembly into the
top turret flue ducting and loosely fit jubilee clip on elbow of the
flue duct extension, see diagram 5.4.
Refit fan and flue hood assembly, ensuring that the flue hood fits
in the flue hood retaining clamps and engage the fan into the
elbow of flue duct extension, see diagram 8.3
Tighten up left hand flue hood securing screw, replace the right
hand one and tighten, see diagram 8.3.
Secure fan to elbow of flue duct extension by tightening up
jubilee clip, see diagram 5.4.
WING
NUT
9270