Protherm Panther 25 (12) KOO User Manual - Contents

Manual is about: Wall-hang non-condensing boiler

Summary of Panther 25 (12) KOO

  • Page 1

    30 ktv v.19 25 ktv v.19 25 kov v.19 25 (12) kto v.19 25 (12) koo v.19 wall-hang non-condensing boiler power 10,4 - 29,6 (3,4 - 12,6) kw flow heating hw (external hw tank) panther v e r s i o n user manual en.

  • Page 3: Contents

    - 1 - contents study this manual carefully 1 read me ..................................................................................................... 3 1.1 welcome ........................................................................................... 3 1.2 user’s quick start manual ..........

  • Page 4: Contents

    - 2 - contents 8.16 operating sketch of 25(12) kto ..................................................... 18 8.17 air and exhaust lines ...................................................................... 19 8.18 connecting the boiler to the electricity supply ................................ 25 8....

  • Page 5

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 3 - study this manual carefully study this manual carefully 1 read me 1.1 welcome this manual is part of the equipment and following installation it must be provided to the user in compliance with valid regulations. Study the handbook car...

  • Page 6

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 4 - study this manual carefully the boiler (as well as all its optional accessories) complies with the requirements of european directive 90/396/eec on gas-fuelled appliances and european directive 92/42/eec on effi ciency, the european d...

  • Page 7

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 5 - study this manual carefully suffi cient to keep the surface temperature of these materials below 80°c. The minimum working (unhindered) space in close proximity to the boiler must be such that the boiler can be worked with easily and ...

  • Page 8

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 6 - study this manual carefully we bear no responsibility for damages resulting from failure to observe the instructions. 3.2 explanation of symbols a danger: risk of injury. E danger: risk of electric shock. B caution: risk of damage to ...

  • Page 9

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 7 - study this manual carefully • be prudent when using the hot water tap. Water coming out of this tap may be scalding. This equipment contains metal parts (components). In working with it and in cleaning it, particularly its corners, yo...

  • Page 10

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 8 - study this manual carefully 7 packing list 1 2 3 6 7 4 5 8 9 legend 1 boiler 2 draw bar 3* exhaust gas diffuser (only for 12 kto) 4 sealing 5 template 6 butt-end of water intake 7 butt-end of outlet valve 8 service manual 9 warranty *...

  • Page 11

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 9 - how to use the boiler how to use the boiler 8 using the equipment 8.1 overview 8.2 turning on and off the boiler is turned on and off at the main switch, which is located on the control panel of the boiler. 8.2.1 display icons when yo...

  • Page 12

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 10 - how to use the boiler 8.3.3 setting the temperature of the central heating water press the (+) or (-) key, followed by the mode key, and the ch value will begin to fl ash. Pressing the (+) or (-) keys sets the desired ch temperature ...

  • Page 13

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 11 - how to use the boiler 8.5 boiler connection parameters 8.5.1 panther 30 ktv 360 450 Ø46 807 230 225 110 65 116 65 94 217 27 208 181 8.5.2 panther 25 (12) koo, 25 kov 311 410 742 179 205 Ø125 8.5.3 panther 25 ktv, 25 kto 311 410 Ø41 7...

  • Page 14

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 12 - how to use the boiler 205 160 134 26 82 65 116 65 82 8.5.4 panther 12 kto 311 410 Ø36 742 158 175 (Ø43) 8.6 connecting the boiler to the ch, hw and gas piping the boiler connection terminals may not be placed under undue pressure fro...

  • Page 15

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 13 - how to use the boiler 8.7 operating pressure in the heating circuit the heating system (measured at the boiler) must be fi lled to a hydraulic pressure of at least 1 bar (corresponding to a hydrostatic height of water of 10 m.) the r...

  • Page 16

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 14 - how to use the boiler of water in the ch circuit (see the project installation documentation). 8.11 safety valve the safety valve is located the underside of the boiler on the left of the hydraulic block. Draining from the safety val...

  • Page 17

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 15 - how to use the boiler 8.13 operating sketch of 25 kov 1 a b c d e 1 2 3 4 5 6 7 8 9 10 20 19 17 18 16 14 13 12 15 11 legend 1 safety valve 2 gas valve 3 hw exchanger 4 discharge valve 5 burner 6 ignition electrodes 7 ntc ch water int...

  • Page 18

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 16 - how to use the boiler 8.14 operating sketch of 30 ktv and 25 ktv 1 2 3 4 5 6 7 8 9 10 11 a b c d e 21 20 18 19 17 15 14 13 16 12 legend 1 safety valve 2 gas valve 3 hw exchanger 4 discharge valve 5 burner 6 ignition electrodes 7 ntc ...

  • Page 19

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 17 - how to use the boiler 8.15 operating sketch of 25 (12) koo 1 1 2 3 4 5 6 7 8 9 a b c d e 16 15 13 12 11 14 10 legend 1 safety valve 2 gas valve 3 discharge valve 4 burner 5 ignition electrodes 6 ntc ch water intake temperature sensor...

  • Page 20

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 18 - how to use the boiler 8.16 operating sketch of 25 (12) kto 1 2 3 4 5 6 7 8 9 10 a b c d e 17 16 14 13 12 15 11 legend 1 safety valve 2 gas valve 3 discharge valve 4 burner 5 ignition electrodes 6 ntc ch water intake temperature senso...

  • Page 21

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 19 - how to use the boiler 8.17 air and exhaust lines the type kov and koo is designed for combustion gases to be removed and discharged into a chimney (through a chimney inlet) with a minimum stabilised thrust of 2 pa. The boiler is conn...

  • Page 22

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 20 - how to use the boiler 8.17.3 the c 32 method (ktv, kto) vertical routes and vertical venting into an open space. An example of a vertical coaxial pipe route: version c 32 (complies with stn en 483) 8.17.4 the c 42 method (ktv, kto) c...

  • Page 23

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 21 - how to use the boiler for venting exhaust and bringing in air for combustion, separate piping may be used. The separate piping may not be routed on opposing walls of the building. Attention! Any duct crossing a wall that exceeds the ...

  • Page 24

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 22 - how to use the boiler 8.17.8 the b 22p method (only for 30ktv) 8.17.9 piping gradient the layout of the piping must permit a down-gradient of the exhaust piping towards the boiler at a nominal gradient of 3 percent. A device for draw...

  • Page 25

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 23 - how to use the boiler boiler method fume diameter diffuser diameter min max comment 25 ktv / 25 kto c12 60/100 - 0.3 3.5 with elbow 90° 41 0.5 with elbow 90° 80/125 - 0.5 11 with elbow 90° 41 1 with elbow 90° c32 60/100 - 1 4.5 no el...

  • Page 26

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 24 - how to use the boiler sketch of the zone from the axis of the aperture of the exhaust stack sited close to the upper part of the window - dual apertures set level in a fl at exterior wall distances of dual apertures set level with ea...

  • Page 27

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 25 - how to use the boiler 8.17.12 safety measures the distance of fl ammable materials from the exhaust component of the separate piping must be enough to ensure that the temperature at the surface of these materials is no higher than 80...

  • Page 28

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 26 - how to use the boiler by the manufacturer with a connector and is located in the frame of the boiler control panel. Room regulators may be connected to the panther boiler via ebus communication. For this type of equipment, however, w...

  • Page 29

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 27 - need help? 8.19 boiler wiring diagram 1 10 2 11 3 12 4 13 5 14 6 15 7 16 8 17 9 18 10 5 9 4 8 3 7 2 6 1 1 2 3 4 10 9 8 7 6 5 4 3 2 1 19 20 18 17 16 15 14 13 12 11 m d t t ntc ebus 24 v x2 x30 x90 x32 x40 x51 x31 x25 x21 x13 230 vac l...

  • Page 30

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 28 - need help? Need help? 9 troubleshooting this section contains all possible error codes together with the appropriate solutions that the user may carry out to restore the boiler to operation — corrective measures. Other error codes mu...

  • Page 31

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 29 - need help? Code description f24 low water level: rapid temperature rise f25 high fl ow temperature f26 incorrect fl ow value from stepmotor gas valve f27 flame sensing error – ionisation signal contrary to closed gas valve f28 failur...

  • Page 32

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 30 - need help? Code description f75 permanent failure ch pressure sensor. No rise in pressure detected following pump start f76 thermal fuse failure in primary exchanger f80 error in she entry sensor f81 error in charger pump f82 error i...

  • Page 33

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 31 - need help? • if water must be discharged from the boiler or from the circuit, it must not be dangerously hot • if water leaks from the boiler exchanger or if the exchanger fi lls with ice do not attempt to start the boiler until norm...

  • Page 34

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 32 - need help? 16 technical parameters description units panther 30 ktv gas category ii2h3p distribution c12, c32, c42, c52, c82, b22p ignition electronic power / fuel natural gas propane maximum thermal consumption kw 32,5 minimum therm...

  • Page 35

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 33 - need help? Description units panther 30 ktv quantity of hw drawn (at ∆t 30°c) l/min 14 temperature range °c 38 - 60 electrical data voltage / frequency v/hz 230/50 consumption w 152 electrical casings ipx4 current a 0,66 exhaust vent...

  • Page 36

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 34 - need help? Description units panther 25 kov gas category ii2h3p distribution b11bs ignition electronic power/ fuel natural gas propane maximum thermal consumption kw 26,8 minimum thermal consumption kw 9,9 maximum thermal output kw 2...

  • Page 37

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 35 - need help? Description units panther 25 kov quantity of hw drawn (at ∆t 30°c) l/min 12,01 temperature range °c 38 - 60 electrical data voltage / frequency v/hz 230/50 consumption w 92 electrical casings ipx4 current a 0,4 exhaust ven...

  • Page 38

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 36 - need help? Description units panther 25 koo gas category ii2h3p distribution b11bs ignition electronic power/ fuel natural gas propane maximum thermal consumption kw 26,8 minimum thermal consumption kw 9,9 maximum thermal output kw 2...

  • Page 39

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 37 - need help? Description units panther 25 koo quantity of hw drawn (at ∆t 30°c) l/min - temperature range °c - electrical data voltage / frequency v/hz 230/50 consumption w 92 electrical casings ipx4 current a 0,4 exhaust venting metho...

  • Page 40

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 38 - need help? Description units panther 25 ktv gas category ii2h3p distribution c12, c32, c42, c52, c82, b22 ignition electronic power/ fuel natural gas propane maximum thermal consumption kw 26,5 minimum thermal consumption kw 10,6 max...

  • Page 41

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 39 - need help? Description units panther 25 ktv quantity of hw drawn (at ∆t 30°c) l/min 12,01 temperature range °c 38 - 60 electrical data voltage / frequency v/hz 230/50 consumption w 147 electrical casings ipx4 current a 0,4 exhaust ve...

  • Page 42

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 40 - need help? Description units panther 25 kto gas category ii2h3p distribution c12, c32, c42, c52, c82, b22 ignition electronic power/ fuel natural gas propane maximum thermal consumption kw 26,5 minimum thermal consumption kw 10,6 max...

  • Page 43

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 41 - need help? Description units panther 25 kto quantity of hw drawn (at ∆t 30°c) l/min - temperature range °c - electrical data voltage / frequency v/hz 230/50 consumption w 147 electrical casings ipx4 current a 0,4 exhaust venting meth...

  • Page 44

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 42 - need help? Description units panther 12 koo gas category ii2h3p distribution b11bs ignition electronic power/ fuel natural gas propane maximum thermal consumption kw 13,8 minimum thermal consumption kw 4,2 maximum thermal output kw 1...

  • Page 45

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 43 - need help? Description units panther 12 koo quantity of hw drawn (at ∆t 30°c) l/min - temperature range °c - electrical data voltage / frequency v/hz 230/50 consumption w 85 electrical casings ipx4 current a 0,5 exhaust venting metho...

  • Page 46

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 44 - need help? Description units panther 12 kto gas category ii2h3p distribution c12, c32, c42, c52, c82, b22 ignition electronic power/ fuel natural gas propane maximum thermal consumption kw 13,8 minimum thermal consumption kw 4,4 maxi...

  • Page 47

    P2_panther_user manual_ work basis_en_03 - 07/11 - protherm - 45 - need help? Description units panther 12 kto quantity of hw drawn (at ∆t 30°c) l/min - temperature range °c - electrical data voltage / frequency v/hz 230/50 consumption w 110 electrical casings ipx4 current a 0,61 exhaust venting met...

  • Page 50

    Www.Protherm.Eu p2 _p an th er _u ser ma nu al_ wo rk ba sis_ en _0 3 - 07 /11 insert the bar code protherm spol. S r.O. Pplk. Pľjušťa 45 909 01 skalica tel.: 034 6966 101 fax: 034 6966 111.