Proware EP-3164D-GAS3 User manual

Manual is about: iSCSI GbE to SAS/SATA II RAID Subsystem

Summary of EP-3164D-GAS3

  • Page 1

    Iscsi gbe to sas/sata ii raid subsystem user manual revision 1.1.

  • Page 2: Table of Contents

    Iscsi gbe to sas/sata ii raid subsystem 2 user manual table of contents preface ................................................................................................................................ 6 before you begin ...........................................................................

  • Page 3

    Iscsi gbe to sas/sata ii raid subsystem user manual 3 4.1 management interfaces ...................................................................................................................................... 36 4.1.1 serial console port ...........................................................

  • Page 4

    Iscsi gbe to sas/sata ii raid subsystem 4 user manual 5.5.4 hard drive s.M.A.R.T. Support ................................................................................................................. 88 5.6 system maintenance .........................................................................

  • Page 5

    Iscsi gbe to sas/sata ii raid subsystem user manual 5 chapter 7 troubleshooting .................................................................................... 134 7.1 system buzzer ....................................................................................................................

  • Page 6: Preface

    Iscsi gbe to sas/sata ii raid subsystem 6 user manual preface about this manual this manual provides information regarding the quick installation and hardware features of the raid subsystem. This document also describes how to use the storage management software. Information contained in the manual ...

  • Page 7: Before You Begin

    Iscsi gbe to sas/sata ii raid subsystem user manual 7 before you begin before going through with this manual, you should read and focus to the following safety guidelines. Notes about the subsystem’s controller configuration and the product packaging and delivery are also included. Safety guidelines...

  • Page 8

    Iscsi gbe to sas/sata ii raid subsystem 8 user manual the shipping package contains the following: note: if any damage is found, contact the dealer or vendor for assistance. Iscsi raid subsystem unit two (2) power cords two (2) ethernet lan cables two(2) lc-lc fibre optical cables two (2) external n...

  • Page 9: Chapter 1   Introduction

    Iscsi gbe to sas/sata ii raid subsystem user manual 9 chapter 1 introduction the iscsi raid subsystem unparalleled performance & reliability ƒ front-end 4 x 10gb iscsi ƒ supports 802.3ad port trunking, link aggregation control protocol (lacp) ƒ high data bandwidth of system architecture by powerful ...

  • Page 10

    Iscsi gbe to sas/sata ii raid subsystem 10 user manual features ƒ front-end 4 x 10gb ports support independent access, fail-over and load- balancing ƒ (802.3ad port trunking, lacp) ƒ supports iscsi jumbo frame ƒ supports microsoft multipath i/o (mpio) ƒ supports raid levels 0, 1, 0+1, 3, 5, 6, 10, 3...

  • Page 11

    Iscsi gbe to sas/sata ii raid subsystem user manual 11 1.1 technical specifications model ep-3164d-gas3 raid controller iscsi-sas controller dual (redundant) host interface four 10gb/s ethernet disk interface sas 3gb or sata ii sas expansion 4x mini sas (3gb/s) processor type intel iop342 64-bit (ch...

  • Page 12

    Iscsi gbe to sas/sata ii raid subsystem 12 user manual snapshot rollback mechanism support yes platform rackmount form factor 3u # of hot swap trays 16 tray lock yes disk status indicator access / fail led backplane sas / sata ii single bp # of ps/fan modules 500w x 2 w/pfc # of fans 4 power require...

  • Page 13

    Iscsi gbe to sas/sata ii raid subsystem user manual 13 1.2 terminology the document uses the following terms: raid redundant array of independent disks. There are different raid levels with different degree of data protection, data availability, and performance to host environment. Pd the physical d...

  • Page 14

    Iscsi gbe to sas/sata ii raid subsystem 14 user manual dg degraded mode. Not all of the array’s member disks are functioning, but the array is able to respond to application read and write requests to its virtual disks. Scsi small computer systems interface. Sas serial attached scsi. S.M.A.R.T. Self...

  • Page 15

    Iscsi gbe to sas/sata ii raid subsystem user manual 15 1.3 raid levels the subsystem can implement several different levels of raid technology. Raid levels supported by the subsystem are shown below. Raid level description min. Drives 0 block striping is provide, which yields higher performance than...

  • Page 16

    Iscsi gbe to sas/sata ii raid subsystem 16 user manual 1.4 volume relationship diagram this is the design of volume structure of the iscsi raid subsystem. It describes the relationship of raid components. One rg (raid group) consists of a set of vds (virtual disk) and owns one raid level attribute. ...

  • Page 17

    Iscsi gbe to sas/sata ii raid subsystem user manual 17 chapter 2 identifying parts of the raid subsystem the illustrations below identify the various parts of the subsystem. 2.1 main components 2.1.2 front view.

  • Page 18

    Iscsi gbe to sas/sata ii raid subsystem 18 user manual 2.1.2.1 disk trays hdd status indicator part function hdd activity led this led will blink blue when the hard drive is being accessed. Hdd fault led green led indicates power is on and hard drive status is good for this slot. If hard drive is de...

  • Page 19

    Iscsi gbe to sas/sata ii raid subsystem user manual 19 2.1.2.2 lcd front panel smart function front panel the smart lcd panel is an option to configure the raid subsystem. If you are configuring the subsystem using the lcd panel, press the select button to login and configure the raid subsystem. Par...

  • Page 20

    Iscsi gbe to sas/sata ii raid subsystem 20 user manual environment status leds parts function power led green led indicates power is on. Power fail led if a redundant power supply unit fails, this led will turn to red and alarm will sound. Fan fail led when a fan fails or the fan’s rotational speed ...

  • Page 21

    Iscsi gbe to sas/sata ii raid subsystem user manual 21 2.1.2 rear view 1. Controller module the subsystem has one or two controller modules. 2. Power supply unit 1 ~ 2 two power supplies (power supply 1 and power supply 2) are located at the rear of the subsystem. Each psfm has one power supply and ...

  • Page 22

    Iscsi gbe to sas/sata ii raid subsystem 22 user manual 2.2 controller module raid controller module 2.2.1 controller module panel note: only data port lan1 is available in default system configuration. Data port lan2 is optional. It can be purchased separately for upgrade..

  • Page 23

    Iscsi gbe to sas/sata ii raid subsystem user manual 23 1. Uninterrupted power supply (ups) port (apc smart ups only) the subsystem may come with an optional ups port allowing you to connect an apc smart ups device. Connect the cable from the ups device to the ups port located at the rear of the subs...

  • Page 24

    Iscsi gbe to sas/sata ii raid subsystem 24 user manual 2.3 power supply / fan module (psfm) the raid subsystem contains two 500w power supply / fan modules. All the power supply / fan modules (psfms) are inserted into the rear of the chassis. 2.3.1 psfm panel the panel of the power supply/fan module...

  • Page 25

    Iscsi gbe to sas/sata ii raid subsystem user manual 25 note: each psfm has one power supply and two fans. The psfm 1 has power#1, fan#1 and fan#2. The psfm 2 has power#2, fan#3 and fan#4. When the power supply of a psfm fails, the psfm need not be removed from the slot if replacement is not yet avai...

  • Page 26

    Iscsi gbe to sas/sata ii raid subsystem 26 user manual for better data service availability, all the connections among host servers, gbe switches, and the dual controllers are recommended as redundant as below..

  • Page 27

    Iscsi gbe to sas/sata ii raid subsystem user manual 27 chapter 3 getting started with the subsystem 3.1 connecting the iscsi raid subsystem to the network to connect the iscsi unit to the network, insert the network cable that came with the unit into the network port (lan1) at the back of iscsi unit...

  • Page 28

    Iscsi gbe to sas/sata ii raid subsystem 28 user manual 3.3 disk drive installation this section describes the physical locations of the hard drives supported by the subsystem and give instructions on installing a hard drive. The subsystem supports hot-swapping allowing you to install or replace a ha...

  • Page 29

    Iscsi gbe to sas/sata ii raid subsystem user manual 29 4. Place the hard drive in the disk tray. Turn the disk tray upside down. Align the four screw holes of the sas disk drive in the four hole a of the disk tray. To secure the disk drive into the disk tray, tighten four screws on these holes of th...

  • Page 30

    Iscsi gbe to sas/sata ii raid subsystem 30 user manual 5. Slide the tray into a slot. 6. Press the lever in until you hear the latch click into place. The hdd fault led will turn green when the subsystem is powered on and hdd is good. 7. If necessary, lock the disk tray by turning the lock groove..

  • Page 31

    Iscsi gbe to sas/sata ii raid subsystem user manual 31 3.3.2 installing a sata disk drive (dual controller mode) in a disk tray 1. Remove an empty disk tray from the subsystem. 2. Prepare the dongle board and two screws. 3. Place the dongle board in the disk tray. Turn the tray upside down. Align th...

  • Page 32

    Iscsi gbe to sas/sata ii raid subsystem 32 user manual note: all the disk tray holes are labelled accordingly. 4. Place the sata disk drive into the disk tray. Slide the disk drive towards the dongle board. Tray hole d.

  • Page 33

    Iscsi gbe to sas/sata ii raid subsystem user manual 33 5. Turn the disk tray upside down. Align the four screw holes of the sata disk drive in the four hole c of the disk tray. To secure the disk drive into the disk tray, tighten four screws on these holes of the disk tray. Note in the picture below...

  • Page 34

    Iscsi gbe to sas/sata ii raid subsystem 34 user manual 3.4 iscsi introduction iscsi (internet scsi) is a protocol which encapsulates scsi (small computer system interface) commands and data in tcp/ip packets for linking storage devices with servers over common ip infrastructures. Iscsi provides high...

  • Page 35

    Iscsi gbe to sas/sata ii raid subsystem user manual 35 the host side needs an iscsi initiator. The initiator is a driver which handles the scsi traffic over iscsi. The initiator can be software or hardware (hba). Please refer to the certification list of iscsi hba(s) in appendix a. Os native initiat...

  • Page 36: Chapter 4   Quick Setup

    Iscsi gbe to sas/sata ii raid subsystem 36 user manual chapter 4 quick setup 4.1 management interfaces there are three management methods to manage the iscsi raid subsystem described as follows: 4.1.1 serial console port use null modem cable to connect console port. The console settings are on the f...

  • Page 37

    Iscsi gbe to sas/sata ii raid subsystem user manual 37 4.1.3 lcd control module (lcm) after booting up the system, the following screen shows management port ip and model name: 192.168.10.50 iscsi-model press “enter” button, the lcm functions “system info.”, “alarm mute”, “reset/shutdown”, “quick in...

  • Page 38

    Iscsi gbe to sas/sata ii raid subsystem 38 user manual the following is lcm menu hierarchy. Proips cd [system info.] [firmware version x.X.X] [ram size xxx mb] [alarm mute] [cyes nod] [reset/shutdown] [reset] [cyes nod] [shutdown] [cyes nod] [quick install] raid 0 raid 1 raid 3 raid 5 raid 6 raid 0+...

  • Page 39

    Iscsi gbe to sas/sata ii raid subsystem user manual 39 caution! Before power off, it is better to execute “shutdown” to flush the data from cache to physical disks. 4.1.4 web gui the iscsi raid subsystem supports graphical user interface (gui) to operate the system. Be sure to connect the lan cable....

  • Page 40

    Iscsi gbe to sas/sata ii raid subsystem 40 user manual there are seven indicators at the top-right corner. Raid light: x green Æ raid works well. X red Æ raid fails. Temperature light: x green Æ temperature is normal. X red Æ temperature is abnormal. Voltage light: x green Æ voltage is normal. X red...

  • Page 41

    Iscsi gbe to sas/sata ii raid subsystem user manual 41 4.2 how to use the system quickly 4.2.1 quick installation it is easy to use “quick installation” to create a volume. It uses all available physical disks to create a rg; the system will calculate maximum spaces on raid levels 0/1/3/5/6/0+1. “qu...

  • Page 42

    Iscsi gbe to sas/sata ii raid subsystem 42 user manual step2: confirm the management port ip address and dns, and then click “next”. Step 3: set up the data port ip and click “next”..

  • Page 43

    Iscsi gbe to sas/sata ii raid subsystem user manual 43 step 4: set up the raid level and volume size and click “next”. Step 5: check all items, and click “finish”. Step 6: done..

  • Page 44

    Iscsi gbe to sas/sata ii raid subsystem 44 user manual 4.2.2 volume creation wizard “volume create wizard” has a smarter policy. When the system is inserted with some hdds. “volume create wizard” lists all possibilities and sizes in different raid levels, it will use all available hdds for raid leve...

  • Page 45

    Iscsi gbe to sas/sata ii raid subsystem user manual 45 step 2: please select the combination of the rg capacity, or “use default algorithm” for maximum rg capacity. After rg size is chosen, click “next”. Step 3: decide vd size. User can enter a number less or equal to the default number. Then click ...

  • Page 46

    Iscsi gbe to sas/sata ii raid subsystem 46 user manual step 4: confirmation page. Click “finish” if all setups are correct. Then a vd will be created. Step 5: done. The system is available now. Note: a virtual disk of raid 0 is created and is named by system itself..

  • Page 47: Chapter 5   Configuration

    Iscsi gbe to sas/sata ii raid subsystem user manual 47 chapter 5 configuration 5.1 web gui management interface hierarchy the below table is the hierarchy of the management gui. System configuration system setting Æ system name / date and time / system indication network settin g Æ mac address / add...

  • Page 48

    Iscsi gbe to sas/sata ii raid subsystem 48 user manual firmware sync hronization Æ synchronize the slave controller’s firmware version with the master’s reset to factor y default Æ sure to reset to factory default? Import and export import/export / import file reboot and shu tdown Æ reboot / shutdow...

  • Page 49

    Iscsi gbe to sas/sata ii raid subsystem user manual 49 5.2 system configuration “system configuration” is designed for setting up the “system setting”, “network setting”, “login setting”, “mail setting”, and “notification setting”. 5.2.1 system setting “system setting” can be used to set system name...

  • Page 50

    Iscsi gbe to sas/sata ii raid subsystem 50 user manual 5.2.2 network setting “network setting” is for changing ip address for remote administration usage. There are 2 options, dhcp (get ip address from dhcp server) and static ip. The default setting is dhcp. User can change the http, https, and ssh ...

  • Page 51

    Iscsi gbe to sas/sata ii raid subsystem user manual 51 5.2.3 login setting “login setting” can set single admin, auto logout time and admin/user password. The single admin can prevent multiple users access the same controller at the same time. 1. Auto logout: the options are (1) disable; (2) 5 minut...

  • Page 52

    Iscsi gbe to sas/sata ii raid subsystem 52 user manual 5.2.4 mail setting “mail setting” can accept at most 3 mail-to address entries for receiving the event notification. Some mail servers would check “mail-from address” and need authentication for anti-spam. Please fill the necessary fields and cl...

  • Page 53

    Iscsi gbe to sas/sata ii raid subsystem user manual 53 5.2.5 notification setting “notification setting” can be used to set up snmp trap for alerting via snmp, pop-up message via windows messenger (not msn), alert via syslog protocol, and event log filter. “snmp” allows up to 3 snmp trap addresses. ...

  • Page 54

    Iscsi gbe to sas/sata ii raid subsystem 54 user manual using “system log server”, user can choose the facility and the event log level. The default port of syslog is 514. The default setting enables event level: info, warning and error event logs. There are some syslog server tools. The following we...

  • Page 55

    Iscsi gbe to sas/sata ii raid subsystem user manual 55 5.3.1 nic “nic” function is used to change the ip addresses of iscsi data ports. The iscsi raid subsystem has two 10gbe ports on each controller to transmit data. Each of them must be assigned to one ip address in multi-homed mode unless the lin...

  • Page 56

    Iscsi gbe to sas/sata ii raid subsystem 56 user manual mtu / jumbo frame: mtu (maximum transmission unit) size can be enabled by moving mouse to the gray button of lan port, click “enable jumbo frame”. Maximum jumbo frame size is 3900 bytes. Warning! The mtu size of network switch and hba on host mu...

  • Page 57

    Iscsi gbe to sas/sata ii raid subsystem user manual 57 for example, lan1 and lan2 are set to trunking mode. To remove trunking/lacp setting, check the gray button of lan port, click “delete link aggregation”. Then it will pop up a message to confirm. Ping host: user can ping the corresponding host d...

  • Page 58

    Iscsi gbe to sas/sata ii raid subsystem 58 user manual 5.3.2 entity property “entity property” is used to view the entity name of the iscsi raid subsystem, and setup “isns ip” for isns (internet storage name service). Isns protocol allows automated discovery, management and configuration of iscsi de...

  • Page 59

    Iscsi gbe to sas/sata ii raid subsystem user manual 59 5.3.3 node “node” can be used to view the target name for iscsi initiator. The iscsi raid subsystem supports up to 32 multinodes. There are 32 default nodes created for each controller. Chap: chap is the abbreviation of challenge handshake autho...

  • Page 60

    Iscsi gbe to sas/sata ii raid subsystem 60 user manual 4. Click “ok”. 5. Go to “/ iscsi configuration / chap account” page to create chap account. Please refer to next section for more detail. 6. Check the gray button of “op.” column, click “user”. 7. Select chap user(s) which will be used. It’s a m...

  • Page 61

    Iscsi gbe to sas/sata ii raid subsystem user manual 61 change portal: users can change the portals belonging to the device node of each controller. 1. Check the gray button of “op.” column next to one device node. 2. Select “change portal”. 3. Choose the portals for the controller. 4. Click “ok” to ...

  • Page 62

    Iscsi gbe to sas/sata ii raid subsystem 62 user manual 5.3.4 session “session” can display iscsi session and connection information, including the following items: 1. Tsih (target session identifying handle) 2. Host (initiator name) 3. Controller (target name) 4. Initialr2t(initial ready to transfer...

  • Page 63

    Iscsi gbe to sas/sata ii raid subsystem user manual 63 5.3.5 chap account “chap account” is used to manage chap accounts for authentication. This iscsi raid subsystem allows creation of many chap accounts. To setup chap account, please follow these steps: 1. Click “create”. 2. Enter “user”, “secret”...

  • Page 64

    Iscsi gbe to sas/sata ii raid subsystem 64 user manual 5.4 volume configuration “volume configuration” is designed for setting up the volume configuration which includes “physical disk”, “raid group”, “virtual disk”, “snapshot”, and “logical unit”. 5.4.1 physical disk “physical disk” can be used to ...

  • Page 65

    Iscsi gbe to sas/sata ii raid subsystem user manual 65 physical disk: physical disks in slot 1, 2, 3 are created for a rg named “rg-r5”. Slot 4 is set as dedicated spare disk of the rg named “rg-r5”. The others are free disks.) step 4: the unit of size can be changed from (gb) to (mb). It will displ...

  • Page 66

    Iscsi gbe to sas/sata ii raid subsystem 66 user manual status the status of hard drive. “online” Æ the hard drive is online. “rebuilding” Æ the hard drive is being rebuilt. “transition” Æ the hard drive is being migrated or is replaced by another disk when rebuilding occurs. “scrubbing” Æ if the har...

  • Page 67

    Iscsi gbe to sas/sata ii raid subsystem user manual 67 pd operations description: set free disk make the selected hard drive to be free for use. Set global spare set the selected hard drive to global spare of all rgs. Set dedicated spares set hard drive to dedicated spare of selected rgs. Upgrade up...

  • Page 68

    Iscsi gbe to sas/sata ii raid subsystem 68 user manual step 2: confirm page. Click “ok” if all setups are correct. There is a raid 0 with 4 physical disks, named “rg-r0”. The second raid group is a raid 5 with 3 physical disks, named “rg-r5” step 3: done. View “raid group” page. Rg column descriptio...

  • Page 69

    Iscsi gbe to sas/sata ii raid subsystem user manual 69 #vd the number of virtual disks in raid group. Status the status of raid group. “online” Æ the raid group is online. “offline” Æ the raid group is offline. “rebuild” Æ the raid group is being rebuilt. “migrate” Æ the raid group is being migrated...

  • Page 70

    Iscsi gbe to sas/sata ii raid subsystem 70 user manual standby options: “disabled” Æ disable spindown. “30 sec / 1 min / 5 min / 30 min” Æ enable hard drive auto spindown to save power in the period of time. Read ahead: “enabled” Æ enable disk read ahead. (default) “disabled” Æ disable disk read ahe...

  • Page 71

    Iscsi gbe to sas/sata ii raid subsystem user manual 71 step 2: confirm page. Click “ok” if all setups are correct. Create a vd named “vd-01”, from “rg-r0”. The second vd is named “vd-02”, it’s initializing. Step 3: done. View “virtual disk” page. Vd column description: the button includes the functi...

  • Page 72

    Iscsi gbe to sas/sata ii raid subsystem 72 user manual x “rebuild” Æ the virtual disk is being rebuilt. X “migrate” Æ the virtual disk is being migrated. X “rollback” Æ the virtual disk is being rolled back. X “parity checking” Æ the virtual disk is being parity check. Type the type of virtual disk:...

  • Page 73

    Iscsi gbe to sas/sata ii raid subsystem user manual 73 vd operations description: create create a virtual disk. Extend extend a virtual disk capacity. Parity check execute parity check for the virtual disk. It supports raid 3 / 5 / 6 / 30 / 50 / 60. Regenerate parity: “yes” Æ regenerate raid parity ...

  • Page 74

    Iscsi gbe to sas/sata ii raid subsystem 74 user manual set clone set the target virtual disk for clone. Clear clone clear clone function. Start clone start clone function. Stop clone stop clone function. Schedule clone set clone function by schedule. Set snapshot space set snapshot space for executi...

  • Page 75

    Iscsi gbe to sas/sata ii raid subsystem user manual 75 5.4.4 snapshot “snapshot” can view the status of snapshot, create and modify snapshots. Please refer to next chapter for more detail about snapshot concept. The following is an example to take a snapshot. Step 1: create snapshot space. In “/ vol...

  • Page 76

    Iscsi gbe to sas/sata ii raid subsystem 76 user manual step 4: expose the snapshot vd. Check the gray button next to the snapshot vd number; click “expose”. Enter a capacity for snapshot vd. If size is zero, the exported snapshot vd will be read only. Otherwise, the exported snapshot vd can be read ...

  • Page 77

    Iscsi gbe to sas/sata ii raid subsystem user manual 77 health the health of snapshot: x “good” Æ the snapshot is good. X “failed” Æ the snapshot fails. Exposure snapshot vd is exposed or not. Right the right of snapshot: x “read-write” Æ the snapshot vd can be read / write. X “read-only” Æ the snaps...

  • Page 78

    Iscsi gbe to sas/sata ii raid subsystem 78 user manual 5.4.5 logical unit “logical unit” can view, create, and modify the status of attached logical unit number(s) of each vd. User can attach lun by clicking the “attach”. “host” must enter with an iscsi node name for access control, or fill-in wildc...

  • Page 79

    Iscsi gbe to sas/sata ii raid subsystem user manual 79 5.4.6 example the following is an example for creating volumes. Example 1 is to create two vds and set a global spare disk. š example 1 example 1 is to create two vds in one rg, each vd uses global cache volume. Global cache volume is created af...

  • Page 80

    Iscsi gbe to sas/sata ii raid subsystem 80 user manual 5. Done. An rg has been created. A raid 5 rg named “rg-r5” with 3 physical disks is created. The total size is 152gb. Because there is no related vd, free size still remains 152gb. Step 2: create vd (virtual disk). To create a data user volume, ...

  • Page 81

    Iscsi gbe to sas/sata ii raid subsystem user manual 81 5. Repeat steps 1 to 4 to create another vd. Two vds, “vd-r5-1” and “vd-r5-2”, were created from rg “rg-r5”. The size of “vd- r5-1” is 50gb, and the size of “vd-r5-2” is 64gb. There is no lun attached. Step 3: attach lun to vd. There are 2 metho...

  • Page 82

    Iscsi gbe to sas/sata ii raid subsystem 82 user manual step 4: set global spare disk. To set global spare disks, please follow the procedures. 1. Select “/ volume configuration / physical disk”. 2. Check the gray button next to the pd slot; click “set global spare”. 3. “global spare” icon is shown i...

  • Page 83

    Iscsi gbe to sas/sata ii raid subsystem user manual 83 3. Done. Then, the vds are deleted. Note: when deleting vd, the attached lun(s) related to this vd will be detached automatically. Step 8: delete rg (raid group). To delete the raid group, please follow the procedures: 1. Select “/ volume config...

  • Page 84

    Iscsi gbe to sas/sata ii raid subsystem 84 user manual 5.5 enclosure management “enclosure management” allows managing enclosure information including “ses configuration”, “hardware monitor”, “s.M.A.R.T.” and “ups”. For the enclosure management, there are many sensors for different purposes, such as...

  • Page 85

    Iscsi gbe to sas/sata ii raid subsystem user manual 85.

  • Page 86

    Iscsi gbe to sas/sata ii raid subsystem 86 user manual if “auto shutdown” has been checked, the system will shutdown automatically when voltage or temperature is out of the normal range. For better data protection, please check “auto shutdown”. For better protection and avoiding single short period ...

  • Page 87

    Iscsi gbe to sas/sata ii raid subsystem user manual 87 ups type select ups type. Choose smart-ups for apc, none for other vendors or no ups. Shutdown battery level (%) when below the setting level, system will shutdown. Setting level to “0” will disable ups. Shutdown delay (s) if power failure occur...

  • Page 88

    Iscsi gbe to sas/sata ii raid subsystem 88 user manual 5.5.3 ses ses represents scsi enclosure services, one of the enclosure management standards. “ses configuration” can enable or disable the management of ses. Enable ses in lun 0, and can be accessed from every host the ses client software is ava...

  • Page 89

    Iscsi gbe to sas/sata ii raid subsystem user manual 89.

  • Page 90

    Iscsi gbe to sas/sata ii raid subsystem 90 user manual 5.6 system maintenance “maintenance” allows the operations of system functions which include “system information” to show the system version and details, “event log” to view system event logs to record critical events, “upgrade” to the latest fi...

  • Page 91

    Iscsi gbe to sas/sata ii raid subsystem user manual 91 5.6.2 event log “event log” can view the event messages. Check the checkbox of info, warning, and error to choose the level of event log display. Click “download” button to save the whole event log as a text file with file name “log-modelname-se...

  • Page 92

    Iscsi gbe to sas/sata ii raid subsystem 92 user manual 5.6.3 upgrade “upgrade” can upgrade firmware. Please prepare new firmware file named “xxxx.Bin” in local hard drive, then click “browse” to select the file. Click “confirm”, it will pop up a message “upgrade system now? If you want to downgrade ...

  • Page 93

    Iscsi gbe to sas/sata ii raid subsystem user manual 93 5.6.4 firmware synchronization “firmware synchronization” can synchronize the firmware version when controller 1 and controller 2’s firmware are different. It will upgrade the firmware of slave controller to master ones no matter what the firmwa...

  • Page 94

    Iscsi gbe to sas/sata ii raid subsystem 94 user manual 5.6.6 import and export “import and export” allows user to save system configuration values: export, and apply all configuration: import. For the volume configuration setting, the values are available in export and not available in import which ...

  • Page 95

    Iscsi gbe to sas/sata ii raid subsystem user manual 95 5.7 home/logout/mute in the right-upper corner of web ui, there are 3 individual icons, “home”, “logout”, and “mute”. 5.7.1 home click “home” to return to home page 5.7.2 logout for security reason, please use “logout” to exit the web ui. To re-...

  • Page 96

    Iscsi gbe to sas/sata ii raid subsystem 96 user manual chapter 6 advanced operations 6.1 volume rebuild if one physical disk from a rg, which is set to a protected raid level (e.G. Raid 3, raid 5, or raid 6), failed or has been unplugged/removed, the status of rg is changed to degraded mode. The sys...

  • Page 97

    Iscsi gbe to sas/sata ii raid subsystem user manual 97 note: “set dedicated spare” is not available if there is no rg, or if rg is set to raid 0 or jbod, because user can not set dedicated spare disk to raid 0 & jbod. Sometimes, rebuild is called recover; they are the same meaning. The following tab...

  • Page 98

    Iscsi gbe to sas/sata ii raid subsystem 98 user manual 6.2 rg migration to do migration, the total size of rg must be larger or equal to the original rg. It does not allow expanding the same raid level with the same hard disks of original rg. Take examples as following. The below operations are not ...

  • Page 99

    Iscsi gbe to sas/sata ii raid subsystem user manual 99 to migrate the raid level, please follow below procedures. 1. Select “/ volume configuration / raid group”. 2. Check the gray button next to the rg number; click “migrate”. 3. Change the raid level by clicking the down arrow to “raid 5”. There w...

  • Page 100

    Iscsi gbe to sas/sata ii raid subsystem 100 user manual 6.3 vd extension to extend vd size, please follow the procedures. 1. Select “/ volume configuration / virtual disk”. 2. Check the gray button next to the vd number; click “extend”. 3. Change the size. The size must be larger than the original, ...

  • Page 101

    Iscsi gbe to sas/sata ii raid subsystem user manual 101 6.4 snapshot / rollback snapshot-on-the-box captures the instant state of data in the target volume in a logical sense. The underlying logic is copy-on-write -- moving out the data which would be written to certain location where a write action...

  • Page 102

    Iscsi gbe to sas/sata ii raid subsystem 102 user manual 6.4.1 create snapshot volume to take a snapshot of the data, please follow the procedures. 1. Select “/ volume configuration / virtual disk”. 2. Move the mouse pointer to the gray button next to the vd number; click “set snapshot space”. 3. Set...

  • Page 103

    Iscsi gbe to sas/sata ii raid subsystem user manual 103 this is the snapshot list of “vd-01”. There are two snapshots. Snapshot vd “snapvd- 01” is exposed as read-only, “snapvd-02” is exposed as read-write. 10. There are two methods to clean all snapshots. In “/ volume configuration / virtual disk”,...

  • Page 104

    Iscsi gbe to sas/sata ii raid subsystem 104 user manual it will take snapshots every month, and keep the last 32 snapshot copies. Note: daily snapshot will be taken every 00:00. Weekly snapshot will be taken every sunday 00:00. Monthly snapshot will be taken every first day of month 00:00. 6.4.3 rol...

  • Page 105

    Iscsi gbe to sas/sata ii raid subsystem user manual 105 3. During rollback, data from snapshot vd to original vd, the original vd can be accessed and the data in vd just like it has finished rollback. At the same time, the other related snap vd(s) cannot be accessed. 4. After rollback, the other sna...

  • Page 106

    Iscsi gbe to sas/sata ii raid subsystem 106 user manual 6.6 vd clone the user can use vd clone function to backup data from source vd to target vd, set up backup schedule, and deploy the clone rules. The procedures of vd clone are on the following: 1. Copy all data from source vd to target vd at the...

  • Page 107

    Iscsi gbe to sas/sata ii raid subsystem user manual 107 3. Here are the objects, a source vd and a target vd. Before starting clone process, it needs to deploy the vd clone rule first. Click “configuration”. 4. There are three clone configurations, describe on the following. X snapshot space: this s...

  • Page 108

    Iscsi gbe to sas/sata ii raid subsystem 108 user manual the threshold setting will monitor the usage amount of snapshot space. When the used snapshot space achieves its threshold, system will automatically take a clone snapshot and start vd clone process. The purpose of threshold could prevent the i...

  • Page 109

    Iscsi gbe to sas/sata ii raid subsystem user manual 109 6. Select the target vd. Then click “confirm”. 7. Now, the clone target “targetvd_r6” has been set. 8. Click “start clone”, the clone process will start. 9. The default setting will create a snapshot space automatically which the capacity is do...

  • Page 110

    Iscsi gbe to sas/sata ii raid subsystem 110 user manual 10. After initiating the snapshot space, it will start cloning. 11. Click “schedule clone” to set up the clone by schedule. 12. There are “set clone schedule” and “clear clone schedule” in this page. Please remember that “threshold” and “restar...

  • Page 111

    Iscsi gbe to sas/sata ii raid subsystem user manual 111 š run out of snapshot space while vd clone while the clone is processing, the increment data of this vd is over the snapshot space. The clone will complete, but the clone snapshot will fail. Next time, when trying to start clone, it will get a ...

  • Page 112

    Iscsi gbe to sas/sata ii raid subsystem 112 user manual 6.7 sas jbod expansion 6.7.1 connecting jbod iscsi raidcontroller suports sas jbod expansion to connect extra sas dual jbod controller. When connecting a dual jbod controller which can be detected in raid subsystem management gui, it will be di...

  • Page 113

    Iscsi gbe to sas/sata ii raid subsystem user manual 113 “/ enclosure management / hardware monitor” can display the hardware status of sas jbods..

  • Page 114

    Iscsi gbe to sas/sata ii raid subsystem 114 user manual.

  • Page 115

    Iscsi gbe to sas/sata ii raid subsystem user manual 115 “/ enclosure management / s.M.A.R.T.” can display s.M.A.R.T. Information of all pds, including local and all sas jbods. Sas jbod expansion has some constraints as described in the followings: 1 user can create raid group among multiple chassis/...

  • Page 116

    Iscsi gbe to sas/sata ii raid subsystem 116 user manual 6.7.2 upgrade firmware of jbod to upgrade the firmware of jbod subsystem, please follow the steps. 1. Please prepare/download the new jbod firmware file and save in local hard drive. 2. There is a hidden web page for jbod firmware upgrade. Plea...

  • Page 117

    Iscsi gbe to sas/sata ii raid subsystem user manual 117 6.8 mpio and mc/s these features come from iscsi initiator. They can be setup from iscsi initiator to establish redundant paths for sending i/o from the initiator to the target. 1. Mpio: in microsoft windows server base system, microsoft mpio d...

  • Page 118

    Iscsi gbe to sas/sata ii raid subsystem 118 user manual difference: mc/s is implemented on iscsi level, while mpio is implemented on the higher level. Hence, all mpio infrastructures are shared among all scsi transports, including fiber channel, sas, etc. Mpio is the most common usage across all os ...

  • Page 119

    Iscsi gbe to sas/sata ii raid subsystem user manual 119 6.9 trunking and lacp link aggregation is the technique of taking several distinct ethernet links to let them appear as a single link. It has a larger bandwidth and provides the fault tolerance ability. Beside the advantage of wide bandwidth, t...

  • Page 120

    Iscsi gbe to sas/sata ii raid subsystem 120 user manual important! Before using trunking or lacp, he gigabit switch must support trunking or lacp and enabled. Otherwise, host cannot connect the link with storage device..

  • Page 121

    Iscsi gbe to sas/sata ii raid subsystem user manual 121 6.10 dual controllers 6.10.1 perform i/o please refer to the following topology and have all the connections ready. To perform i/o on dual controllers, server/host should setup mpio. Mpio policy will keep i/o running and prevent fail connection...

  • Page 122

    Iscsi gbe to sas/sata ii raid subsystem 122 user manual 6.10.2 ownership when creating rg, it will be assigned with a prefered owner, the default owner is controller 1. To change the rg ownership, please follow the procedures. 1. Select “/ volume configuration / raid group”. 2. Check the gray button...

  • Page 123

    Iscsi gbe to sas/sata ii raid subsystem user manual 123 3. Lockdown: dual controller mode. The firmware of two controllers is different or the size of memory of two controllers is different. In this stage, only master controller can work and i/o will force to write through for protecting data. 4. Si...

  • Page 124

    Iscsi gbe to sas/sata ii raid subsystem 124 user manual 6.11 qreplica (optional) qreplica function will help users to replicate data easily through lan or wan from one subsystem to another. The procedures of qreplica are on the following: 1. Copy all data from source vd to target vd at the beginning...

  • Page 125

    Iscsi gbe to sas/sata ii raid subsystem user manual 125 2. The setting can be reverted by select “disable qreplica” in the operation menu. š create backup vd on the target subsystem 1. Before creating the replication job on the source subsystem, user has to create a virtual disk on the target subsys...

  • Page 126

    Iscsi gbe to sas/sata ii raid subsystem 126 user manual 2. The backup vd needs to be attached to a lun id first before creating replication job. š create replication job on the source subsystem 1. If the license key is activated on the subsystem correctly, a new qreplica tab will be added on the web...

  • Page 127

    Iscsi gbe to sas/sata ii raid subsystem user manual 127 2. Select the source vd which will be replicated to the target subsystem and click “next”. Note: if the message displays that there is not enough space for creation, please refer for the section of configure the snapshot space below for solutio...

  • Page 128

    Iscsi gbe to sas/sata ii raid subsystem 128 user manual 4. The qreplica uses standard iscsi protocol for data replication. User has to log on the iscsi node to create the iscsi connection for the data transmission. Enter the chap information if necessary and select the target node to log no. Click “...

  • Page 129

    Iscsi gbe to sas/sata ii raid subsystem user manual 129 6. A new replication job is created and listed on the qreplica page. š run the replication job 1. Click the “op” button on the replication job to open operation menu. Click “start” to run the replication job. 2. Click “start” again to confirm t...

  • Page 130

    Iscsi gbe to sas/sata ii raid subsystem 130 user manual 3. User can monitor the replication job from the “status” information and the progress is expressed by percentage. š create multi-path on the replication job 1. Click the “create multi-path” in the operation menu of the replication job. 2. Ente...

  • Page 131

    Iscsi gbe to sas/sata ii raid subsystem user manual 131 3. Select the iscsi node to log on and click “next”. 4. Choose the same target vd and click “next”. 5. A new target will be added in this replication job as a redundancy path..

  • Page 132

    Iscsi gbe to sas/sata ii raid subsystem 132 user manual š configure the replication job to run by schedule 1. Click “schedule” in the operation menu of the replication job. 2. The replication job can be scheduled to run by day, by week or by month. The execution time can be configurable per user’s n...

  • Page 133

    Iscsi gbe to sas/sata ii raid subsystem user manual 133 1. To configure the snapshot space settings of qreplica, click the “configuration” button. There are three settings in the qreplica configuration menu, the snapshot space specifies the ratio of snapshot space allocated to the source vd automati...

  • Page 134: Chapter 7   Troubleshooting

    Iscsi gbe to sas/sata ii raid subsystem 134 user manual chapter 7 troubleshooting 7.1 system buzzer the system buzzer features are listed below: 1. The system buzzer alarms 1 second when system boots up successfully. 2. The system buzzer alarms continuously when there is error occurred. The alarm wi...

  • Page 135

    Iscsi gbe to sas/sata ii raid subsystem user manual 135 error sata prd mem fail failed to init sata prd memory manager error sata revision id fail failed to get sata revision id error sata set reg fail failed to set sata register error sata init fail core failed to initialize the sata adapter error ...

  • Page 136

    Iscsi gbe to sas/sata ii raid subsystem 136 user manual warning redboot failover redboot failover event occurred warning watchdog shutdown watchdog timeout shutdown occurred warning watchdog reset watchdog timeout reset occurred rms events level type description info console login login from via con...

  • Page 137

    Iscsi gbe to sas/sata ii raid subsystem user manual 137 info vd scrub finished parity checking on vd completes with info vd scrub aborted parity checking on vd stops with info rg migrate started rg starts migration. Info rg migrate finished rg completes migration. Info rg move started rg starts move...

  • Page 138

    Iscsi gbe to sas/sata ii raid subsystem 138 user manual vd . Warning scrub parity recovered the parity at lba regenerated when checking parity on vd . Info pd freed pd has been freed from rg . Info rg imported configuration of rg has been imported. Info rg restored configuration of rg has been resto...

  • Page 139

    Iscsi gbe to sas/sata ii raid subsystem user manual 139 battery backup events level type description info bbm start syncing abnormal shutdown detected, start flushing battery-backed data ( kb). Info bbm stop syncing abnormal shutdown detected, flushing battery- backed data finished info bbm installe...

  • Page 140

    Iscsi gbe to sas/sata ii raid subsystem 140 user manual info pd scrub started jbod pd starts disk scrubbing process. Info pd scrub completed jbod pd completed disk scrubbing process. Warning ps fail power supply of in jbod is fail info ps normal power supply of in jbod is normal warning fan fail coo...

  • Page 141

    Iscsi gbe to sas/sata ii raid subsystem user manual 141 error ipc fw upgrade timeout system firmware upgrade timeout on another controller info config imported config imported hac events level type description info rg owner changed the preferred owner of rg has been changed to controller . Info forc...

  • Page 142: Appendix

    Iscsi gbe to sas/sata ii raid subsystem 142 user manual appendix a. Certification list š iscsi initiator (software) os software/release number microsoft windows microsoft iscsi software initiator release v2.08 system requirements: 1. Windows 2000 server with sp4 2. Windows server 2003 with sp2 3. Wi...

  • Page 143

    Iscsi gbe to sas/sata ii raid subsystem user manual 143 š 10gbe gbic vendor model avago afbr-703sdz (10 gb/s sfp transceiver, 850nm) finisar ftlx8571d3bcv (10 gb/s sfp transceiver, 850nm) š 10gbe switch vendor model dell powerconnect 8024f (24x sfp+ 10gb with 4x combo ports of 10gbase-t) hp procurve...

  • Page 144

    Iscsi gbe to sas/sata ii raid subsystem 144 user manual seagate savvio 15k.2, st9146852ss, 147gb, 15000rpm, sas 2.0, 6.0gb/s, 16m (f/w: 0002) seagate constellation, st9500430ss, 500gb, 7200rpm, sas 2.0, 6.0gb/s, 16m (f/w: 0001) sata 3.5” vendor model hitachi deskstar 7k250, hds722580vlsa80, 80gb, 72...

  • Page 145

    Iscsi gbe to sas/sata ii raid subsystem user manual 145 04.05g04) westem digital re4-gp, wd2002fyps, 2tb, intellipower, sata 3.0gb/s, 64m, ncq (f/w: 04.01g01) westem digital re4, wd2003fyys, 2tb, 7200rpm, sata 3.0gb/s, 64m, ncq (f/w: 01.01d01) westem digital re4, wd1003fbyx, 1tb, 7200rpm, sata 3.0gb...

  • Page 146

    Iscsi gbe to sas/sata ii raid subsystem 146 user manual b. Microsoft iscsi initiator here is the step by step to setup microsoft iscsi initiator. Please visit microsoft website for latest iscsi initiator. This example is based on microsoft windows server 2008 r2. š connect 1. Run microsoft iscsi ini...

  • Page 147

    Iscsi gbe to sas/sata ii raid subsystem user manual 147 3. Click “done”. 4. It can connect to an iscsi disk now..

  • Page 148

    Iscsi gbe to sas/sata ii raid subsystem 148 user manual š mpio service 5. Please run “server manager” with below path: control panel\system and security\administrative tools 6. Click “feature” and select add features. 7. Please choose the checkbox of multipath i/o.

  • Page 149

    Iscsi gbe to sas/sata ii raid subsystem user manual 149 8. Install: 9. Installation succeeded..

  • Page 150

    Iscsi gbe to sas/sata ii raid subsystem 150 user manual š starting iscsi initiator 10. Please run “iscsi initiator” with below path: control panel\system and security\administrative tools 11. Click Æ discovery tab Æ discover portal 12. Input the ip address of controller1.

  • Page 151

    Iscsi gbe to sas/sata ii raid subsystem user manual 151 13. Click discover portal 14. Input ip address of controller2.

  • Page 152

    Iscsi gbe to sas/sata ii raid subsystem 152 user manual 15. Please connect ctrl1 16. Choose checkbox of “enable multipath-path”.

  • Page 153

    Iscsi gbe to sas/sata ii raid subsystem user manual 153 17. Please select the ip address for initiator & target of controller1 18. Please connect ctrl2..

  • Page 154

    Iscsi gbe to sas/sata ii raid subsystem 154 user manual 19. Choose checkbox of “enable multipath-path”. 20. Please select the ip address for initiator & target of controller2..

  • Page 155

    Iscsi gbe to sas/sata ii raid subsystem user manual 155 21. Iscsi initiator install finish. š setup mpio 22. Please run “mpio” with below path: control panel\system and security\administrative tools.

  • Page 156

    Iscsi gbe to sas/sata ii raid subsystem 156 user manual 23. Click tab of “discover multi-paths” 24. Choose checkbox of “add support for iscsi devices 25. Reboot.

  • Page 157

    Iscsi gbe to sas/sata ii raid subsystem user manual 157 š mc/s 26. If running mc/s, please continue. 27. Select one target name, click “properties…”. 28. Click “mcs…” to add additional connections..

  • Page 158

    Iscsi gbe to sas/sata ii raid subsystem 158 user manual 29. Click “add…”. 30. Click “advanced…”. 31. Select initiator ip and target portal ip, and then click “ok”. 32. Click “connect”. 33. Click “ok”..

  • Page 159

    Iscsi gbe to sas/sata ii raid subsystem user manual 159 34. Done..

  • Page 160

    Iscsi gbe to sas/sata ii raid subsystem 160 user manual š disconnect 35. Select the target name, click “disconnect”, and then click “yes”. 36. Done, the iscsi device disconnect successfully..