Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 1 kyalami business park kyalami, midrand 1685 wendywood, 2144 tel: (011) 996-4400 fax: (011) 466-1878 pi hsc816 home security controller programming and installation manual release ve...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 2 table of contents introduction 4 terminology 5-6 arming options arm when faulted 20 auto re-arm 20 quick arm 20 quick bypass 20 siren alert options 19 bus line transceiver adding co...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 3 programming levels 14 siren options alert on keypad arm 19 alert on remote away arm 19 alert on remote home arm 19 siren timer 18 siren trip count 19 siren beep on exit time expired...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 4 introduction: the pi hsc816 is a south african designed and manufactured security system, carrying full icasa licensing and complying with all safety regulations and specifications....
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 5 congratulations on your purchase of the pi hsc816. The south african designed and manufactured solution to all your electronic security requirements. Please take the time to read an...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 6 instant - a zone or input will create an immediate alarm condition when armed. Keypad - the user interface to the control panel, from which all commands and functions are carried ou...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 7 motherboard layout: ac +……………..Ac input maximum 16.5v 40va ac - ………………negative to be taken from any negative (earth) ................ This must be connected to building earth were p...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 8 expander board layout: zone 9 .............. Zone 1 input eol resistor 2k7 c ........................ Common zone 10 ............ Zone 2 input eol resistor 2k7 zone 11 ............ ...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 9 keypad wiring: 4 wire bus line o/p indications (remote led) off = system off. On = system on. Flashing = system alarmed. Keypad led indications: bank 1 led indicates zones 1 to 8. B...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 10 remote expander layout the remote expander is an 8 zone input and 4 trigger output self contained unit with independent charger and battery. Connection is via the 4 wire bus line a...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 11 bus line codex transceiver. By using the bus line transceiver, the hsc816 has the capability of accepting up to 16 codex transmitters. Each button could be assigned to any of the k...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 12 defaulting the control panel: 1. Default the control panel by removing all power and placing a jumper across lk1. 2. Apply power (ac volts) to the control panel. 3. After +/- 15 se...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 13 step 1 – adding remotes: 1) enter user programming mode. Select # 6. Ready led will flash slowly 2) enter the remote number to be programmed on the keypad 1-8. Key 0 will toggle be...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 14 bottom row of status leds indicate data present in a location. A flashing ready led indicates that the panel is in a programming mode. Binary values: zone led 1 2 3 4 5 6 7 8 9 10 ...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 15 24-hour silent - this zone type when activated will cause an instant alarm condition without any siren but with communicator. 24-hour fire - this zone type when activated will caus...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 16 question 1 to 16: location 1 = zone type location 2 = reserved location 3 = chime and home types location 4 = hardwired / wireless. Location 1 : zone type 0 disabled 1 entry / exit...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 17 question 17 to 37: reserved question 38: expander options select onboard or remote expander location 1 = expander options location 2 = reserved location 3 = reserved location 4 = r...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 18 question 45 : timers location 1 = siren timer location 2 = siren delay timer location 3 = tel line fault timer location 4 = ac fail (random time of 1 to 16 minutes + selection) sir...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 19 question 54: auto test delay location 1= auto test delay location 2=reserved location 3= reserved location 4=reserved value delay 0 1 day 1 2 days 2 3 days 3 4 days 4 5 days 5 6 da...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 20 question 59: arming options location 1 = fast arm location 2 = fast bypass location 3 = arm when faulted location 4 = auto re-arm location 1 location 2 value fast arm 0 1 location ...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 21 question 65: d ialer options: location 1 = reporting formats location 2 = dial attempts location 3 = ring count location 4 = dual reporting. Location 1: select the desired format r...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 22 location 4: question 66: dialer options location 1 = enable dialer location 2 = reporting delay location 3:= dtmf tx level (do not change) location 4 = dtmf rx level.(do not change...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 23 question 84: trigger polarity on power up location 1 = trigger polarity location 2 = reserved location 3: = reserved location 4 = reserved. Location 1: select as positive on power-...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 24 trigger event event restore l 1 l 2 l1 l2 event 24h zone 1 1 0 1 2 event 24h zone 2 2 0 2 2 event 24h zone 3 3 0 3 2 event 24h zone 4 4 0 4 2 event 24h zone 5 5 0 5 2 event 24h zon...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 25 trigger event event restore l1 l2 l1 l2 battery low c c d a zone bypass e a alarm f a any alarm condition keypad duress 1 b keypad medical 4 b keypad panic event b c keypad fire ev...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 26 location 4: trigger action (wireless triggers) wireless triggers can only be timed and location 4 must be selected as a zero for a single transmission. If a trigger number is inser...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 27 q176 l1 to l4 reporting code zone 1 default = 0010 q177 l1 to l4 reporting code zone 2 default = 0010 q178 l1 to l4 reporting code zone 3 default = 0010 q179 l1 to l4 reporting cod...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 28 q283 codex remote4 button 1 button 2 button 3 button 4 q284 codex remote4 button 5 button 6 button 7 button 8 q285 codex remote4 button 9 button 10 button 11 button 12 q286 codex r...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 29 q331 codex remote16 button 1 button 2 button 3 button 4 q332 codex remote16 button 5 button 6 button 7 button 8 q333 codex remote16 button 9 button 10 button 11 button 12 q334 code...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 30 arm home (stay) 3 441 d 0 key switch e=open r=close 409 e 0 time / date inaccurate 1 626 f 0 bell trouble 1 321 0 1 telco fault e=fail r=restore 351 1 1 battery test failure 1 309 ...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 31 24 hour non-burglary - 150 and 160 150 24 hour non-burglary zone 5 2 151 gas detected zone 6 2 152 refrigeration zone 7 2 153 loss of heat zone 8 2 154 water leakage zone 9 2 155 f...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 32 334 repeater failure zone 3 5 335 local printer out of paper zone 4 5 336 local printer failure zone 5 5 337 exp. Module dc loss zone 6 5 338 exp. Module low battery zone 7 5 339 e...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 33 407 remote arm/disarm user 2 8 408 quick arm user 3 8 409 keyswitch o/c user 4 8 441 armed stay user (home) 5 8 442 keyswitch armed stay user 6 8 450 exception o/c user 7 8 451 ear...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 34 525 reversing relay disable zone 1 b 526 notification appliance ckt.# 3 disable zone 2 b 527 notification appliance ckt.# 4 disable zone 3 b system peripheral disables -530 and 540...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 35 651 misc - 650 652 reserved for ademco use zone e d 653 reserved for ademco use user f d 654 reserved for ademco use user 0 e system inactivity zone 1 e default user codes: enter i...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 36 hsc816 programming work sheet installer code is changed in question # 000 question description zone type reserved home 1 or 2 hardwired default 001 zone 1 1004 question description...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 37 question description entry time reserved reserved reserved default 041 entry time 5000 question description exit time reserved reserved reserved default 043 exit time 5000 question...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 38 question description tg 1 to 4 reserved reserved reserved default 084 trig polarity 0000 question description condition reserved reserved reserved default 109 auto arm 0000 questio...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 39 question description digit 1 digit 2 trig num trig action default 142 h/w triggers 0000 question description digit 1 digit 2 trig num trig action default 143 h/w triggers 0000 ques...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 40 question wireless digit 1 digit 2 trig num trig action default 162 triggers 0000 question wireless digit 1 digit 2 trig num trig action default 163 triggers 0000 question wireless ...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 41 question reporting full id d1 full id d2 restricted d1 restricted d2 default 189 codes. Z14 0010 question reporting full id d1 full id d2 restricted d1 restricted d2 default 190 co...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 42 question rpt codes full id d1 full id d2 restricted d1 restricted d2 default 226 kp medical 0010 question rpt codes full id d1 full id d2 restricted d1 restricted d2 default 227 si...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 43 green ready led stops flashes. Repeat for all required users user 1 and 2 master users (all user functions including code changes) users 3 to 12 are normal users (arm and disarm). ...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 44 program codex remotes: two separate stages are required to program the codex remote step 1 – learn the remote into the hsc816 step 2 – define button functions. Step 1 - adding remo...
Pi hsc816 installation manual - revision beta this document and product are copyrighted and all rights are reserved. 45 the zone leds will flash fast to indicate that the zone has triggered enter a user code to cancel walk test or allow to time out after sms control functions: these functions are on...