QED Sample Pro 3 Inch Instruction Manual

Summary of Sample Pro 3 Inch

  • Page 1

    Sample pro 3/4" portable micropurge pump part no. 95192 3-9-04 sample portable pumps micropurge r manual instruction p.O. Box 3726 ann arbor, mi 48106-3726 usa 1-800-624-2026 fax (734) 995-1170 info@qedenv.Com www.Qedenv.Com.

  • Page 3: Contents

    Topic page introduction d escription a ssembly attaching t ubing / disassembly / cleaning / decontamination note figure 2 / main components figure 5 / using needlenose pliers for check ball stop assembly/disassembly figure 6 / pump tubing fitting assembly figure 7 / pump head assembly figure 4/ tubi...

  • Page 4: Introduction

    Ed 1- 80 0- 62 4- 20 26 p a t e n t p e n d in g r w w w .M ic ro pu rg e.C om introduction the sample pro 3/4” portable micropurge pump, ( figure 1) is the first pump de- signed specifically to meet the practical needs of sampling small diameter wells: easy to adjust to low-flow purging rates and e...

  • Page 5: Description

    2 the cap of the pump twists off for full disassembly of the inlet and outlet check valves and the tubing connection components. The pump uses 1/8” o.D. Tubing for compressed gas supply and 1/4” o.D. Tubing for the sample discharge. Tubing connections to the pump are made via push-in fittings built ...

  • Page 6: Description

    3 2 6 6 8 4 11 9 7 7 8 1 3 10 12 14 item no. 2 5 6 7 8 1 1 3 2 2 38434ep 38436 38470 38471 35172 cover grab plate 1/4” tube x 1/8” tube plate 1/4” tube x 1/8” tube o-ring, viton seal discharge seal air supply o-ring, viton ball, teflon ball stop 9 1 38438ep 10 1 38677 38676 qty part no. Description ...

  • Page 7: Assembly

    4 assembly use figure 2, (page 3) to identify main pump components and figure 3, (below) to identify o-ring locations. Detailed exploded view drawing of the upper end of the pump are shown on pages 7 and 8. 1. See figure 3 (below) to identify locations where o-rings and seals are to be installed and...

  • Page 8: Disassembly

    5 disassembly use figure 2, (page 3) to identify main pump components and figure 3, (page 4) to identify o-ring locations. 1. Reverse assembly sequence, taking care to position pump to retain check balls during removal of valve seats and stops. A screwdriver can be used if necessary to remove the in...

  • Page 9: Figure 5

    Using the supplied needlenose pliers for assembly/disassembly needlenose pliers are provided to make handling of certain smaller parts easier to handle during cleaning assembly and disassembly. Figure 5 demonstrates placement of the check ball stop into the pump head. 6 figure 5 assembly/disassembly.

  • Page 10: Figure 6

    Item no. 2 5 7 8 1 1 1 1 1 1 38434ep 38436 38471 35172 cover grab plate 1/4” tube x 1/8” tube o-ring, viton ball, teflon ball stop seal air supply seal discharge plate 9 1 1 38438ep qty part no. Description 7 2 5 11 9 7 8 13 12 1 4 14 13 12 11 1 38833 38435 38677 38676 3/4 sample pro eye bolt figure...

  • Page 11: Figure 7

    1 6 6 7 3 11 item no. 1 3 6 7 1 1 2 1 38437ep 38439ep 38470 38471 head inlet o-ring, viton ball, teflon qty part no. Description 8 figure 7 figure 7.

  • Page 12: Bladder Replacement

    9 head old b ladder b arb o-r ing b arb new b ladder ed 1- 80 0- 62 4- 20 26 p a t e n t p e n d in g r w w w .M ic ro pu rg e.C om ed 1- 80 0- 62 4- 20 26 p a t e n t p e n d in g r w w w .M ic ro pu rg e.C om c over b ody 1. Pull bladder down to remove it from the pump head. 2. Inspect the conditi...

  • Page 13: Specifications

    Fittings: materials: specifications pump volume: .33 ounces (10 milliliters ) the push-in and compression fittings and tubing on the samplepro pump are designed to provide at least 25 lbs. Combined pullout strength when used with qed tubing. Qed is not responsible for loss of the pump if non-qed tub...

  • Page 14: Warranty

    1. Dedicated-use systems products- 10 year warranty on dedicated bladder pumps equip- ped with q.E.D. Inlet screens, and purge pumps used in periodic, non continuous ground water sampling (up to 52 sampling events per yearall other components, equipment and accessories are warranted for one year.) 2...

  • Page 15: Warranty

    12 warranty the foregoing warranty is in lieu of all other warranties, expressed, implied or statutory (including but not limited to the warranties of merchantability and fitness for a particular purpose), which other warranties are expressly excluded hereby and of any other obligations or liabil- i...

  • Page 16

    P.O. Box 3726 ann arbor, mi 48106-3726 usa 1-800-624-2026 fax (734) 995-1170 info@qedenv.Com www.Qedenv.Com.