Quadra-Fire 3100-I Owner's Manual - Caution

Manual is about: ACC wood insert

Summary of 3100-I

  • Page 1

    R do not discard this manual caution • important operating and maintenance instructions included. • leave this manual with party responsible for use and operation. Hot surfaces! Glass and other surfaces are hot during operation and cool down. Warning hot glass will cause burns. • do not touch glass ...

  • Page 2: Caution

    3100-i act wood insert page september 1, 2008 r 250-6381d and welcome to the quadra-fire family ! H earth & home technologies welcomes you to our tradition of excellence! In choosing a quadra-fire appliance, you have our assurance of commitment to quality, durability, and performance. This commitmen...

  • Page 3

    Page 3 september 1, 2008 3100-i act wood insert r 250-638d safety & overview of appliance serial number /listing label location ------------------ dimensions ----------------------------------------------------- 4 minimum clearances to combustibles ------------------ 5 installation recommendations -...

  • Page 4

    3100-i act wood insert page 4 september 1, 2008 r 250-6381d insert dimensions top view side view front view a b cl 27-7/16" (697mm) 14-1/8" (359mm) 38-7/8" (987mm) 12-3/16" (310mm) 8-5/8" (219mm) 5-3/8" (137mm) 22-7/16" (570mm) 23-1/8" (587mm) 21-1/2" (546mm) 20-3/8" (518mm) 26-1/4" (667mm) 7-7//8" ...

  • Page 5

    Page 5 september 1, 2008 3100-i act wood insert r 250-638d hearth extension a b c d f e insert side w all maximum mantel depth - 10" (254mm) fascia or trim mantel thermal protection usa & canada usa canada a sidewall to stove 16" 16" (406mm) b mantel clearances *no mantel shield 33" 34" (864mm) with...

  • Page 6

    3100-i act wood insert page 6 september 1, 2008 r 250-6381d avoid fire: to ensure that insulation or any other combustible material does not contact the chimney, a chimney inside the house must have at least 2 inches (51mm) of air space clearance around t he chimney. A chimney outside the house must...

  • Page 7

    Page 7 september 1, 2008 3100-i act wood insert r 250-638d if installing this model to a masonry chimney, always be sure the chimney is in good condition and that it meets the minimum standards of the national fire protection association (nfpa) standard 211. A factory built chimney must be 6 inch (1...

  • Page 8

    3100-i act wood insert page 8 september 1, 2008 r 250-6381d floor ceiling caulk floor (second story) non-combustible firestopping material minimum 1 inch (25mm) clearance from exterior chimney to sheathing firestopping inch (51mm ) a chimney must be the required height above the roof or other obstru...

  • Page 9

    Page 9 september 1, 2008 3100-i act wood insert r 250-638d masonry fireplace using direct-connect method refer to: clearances to combustibles on page 5, canadian installation requirements on page 11, hearth requirements on page 5 and zero clearance adjustable support kit on page 14. Figure 9a - inst...

  • Page 10

    3100-i act wood insert page 10 september 1, 2008 r 250-6381d the following modifications of factory built fireplaces are permissible: 1) removal of damper; 2) removal of smoke shelf or baffle; 3) removal of ember catches; 4) removal of fire grate; 5) removal of viewing screen/curtain; and, 6) remova...

  • Page 11

    Page 11 september 1, 2008 3100-i act wood insert r 250-638d installation in canada masonry and heat-circulating (installations into factory-built fireplaces are prohibited in canada) whether installed in a masonry or heat-circulating fireplace, this fireplace insert must be installed with a continuo...

  • Page 12

    3100-i act wood insert page 12 september 1, 2008 r 250-6381d vi ew of "l" bracket installed kit includes: ( 2) side panels, left & right; (1) panel top & fastener package; (2) side trim, left & right; (1) trim top & fastener package. Tools needed: powered phillips head screw driver. 1. Install the 2...

  • Page 13

    Page 13 september 1, 2008 3100-i act wood insert r 250-638d included in kit: (2) fan mounts & fan assemblies; (1) speed control, power cord/wire assembly; (1 set) fan connector wires, must be high temperature wire; and (1) strain relief. Tools needed: large phillips screwdriver, pliers fan (blower) ...

  • Page 14

    3100-i act wood insert page 14 september 1, 2008 r 250-6381d zero clearance adjustable trim support, 2” to 10” part no. 841-0990, size 9” x 45” and part no. Adjspt-12, size 12” x 50” included in kit: ( 1) trim top, (1) trim front, (2) trim sides, double-sided tape (already installed) tools needed: p...

  • Page 15: Operation

    Page 15 september 1, 2008 3100-i act wood insert r 250-638d wood selection and storage burn only dry seasoned wood. Dry, well-seasoned wood will not only minimize the chance of creosote formation but will give you the most efficient heat output. Even dry wood contains at least 15% moisture by weight...

  • Page 16

    3100-i act wood insert page 16 september 1, 2008 r 250-6381d burn rates starting fire : open both controls (push in) completely. After a wood load has been burning on high for 5 to 15 minutes or longer for very large pieces, close the start-up air control (right side) by pulling it out. High: leave ...

  • Page 17

    Page 17 september 1, 2008 3100-i act wood insert r 250-638d air quality and your quadra-fire insert in recent years there has been an increasing concern about the quality of our air. Much of the blame for poor air quality has been placed on the burning of wood for home heating. In order to improve t...

  • Page 18

    3100-i act wood insert page 18 september 1, 2008 r 250-6381d maintenance care and cleaning of plated surfaces important: you must clean all the fingerprints and oils from the plated surfaces before firing the insert for the first time. Use warm soapy water and a soft rag, glass cleaner and a paper t...

  • Page 19

    Page 19 september 1, 2008 3100-i act wood insert r 250-638d baffle removal & installation note : the baffle in the 3100-i act insert is 2700° fiber board. Removing hardware exposed to combustion processes can be frustrating. If your reason for removing the baffle is simply to clean the chimney, you ...

  • Page 20

    3100-i act wood insert page 0 september 1, 2008 r 250-6381d exploded view 1 9 10 11 2 4 3 8 6 7 5 item description item description 1 trim ring, louver 7 screen, left/right (interchange - able) manifold tubes, back (3) 8 speed control 3 manifold tube, front (1) 9 baffle, fiberboard 4 spring handle, ...

  • Page 21

    Page 21 september 1, 2008 3100-i act wood insert r 250-638d item # part description alphabetical order sku 9 baffle, fiberboard 831-1800 10 blanket, ceramic, 1 inch thick 832-3401 blower assembly, with wire harness 831-1101 blower cord with speed control & wire harness 832-1400 5 blower assembly 831...

  • Page 22

    3100-i act wood insert page september 1, 2008 r 250-6381d 1 trim ring for louver, gold 430-2691 1 trim ring for louver, nickel 430-5430 upgrade kit to nickel, door uk-drnl 14 washer, spacing sae 3/8 for door handle 220-0010 item # part description alphabetical order sku accessories 15 16 17 18 19 20...

  • Page 23

    Page 23 september 1, 2008 3100-i act wood insert r 250-638d date of service performed by description of service service and maintenance log.

  • Page 24

    3100-i act wood insert page 4 september 1, 2008 r 250-6381d date of service performed by description of service service and maintenance log (cont’d).

  • Page 25

    Page 5 september 1, 2008 3100-i act wood insert r 250-638d homeowner’s notes.

  • Page 26

    3100-i act wood insert page 26 september 1, 2008 r 250-6381d warranty policy hearth & home technologies limited warranty hearth & home technologies (“hht”) and its respective brands extends the following warranty for hht gas, wood, pellet and electric appliances purchased from an authorized hht deal...

  • Page 27

    Page 7 september 1, 2008 3100-i act wood insert r 250-638d hht’s obligation under this warranty does not extend to damages resulting from: (1) installation, operation or main- tenance of the appliance not in accordance with the installation instructions; operating instructions and the listing agent ...

  • Page 28

    Page 28 september 1, 2008 250-6381d r • do not discard this manual. • important operating and maintenance instructions included. • read, understand and follow these instruci- tons for safe installation and operation. • leave this manual with party responsible for use and operation. Caution this prod...