Quadra-Fire 4100I-GD-B Manual

Other manuals for 4100I-GD-B: User Manual
Manual is about: 4100-I ACT Wood Insert

Summary of 4100I-GD-B

  • Page 1

    Do not discard this manual notice • important operating a n d m a i n t e n a n c e instructions included. • leave this manual with party responsible for use and operation. • read, understand and follow these instructions for safe installation and operation. Do n o t dis ca rd warning if the informa...

  • Page 2: Caution

    4100-i act wood insert page 2 march 27, 2008 r 250-7201 rev d and welcome to the quadra-fire family ! Hearth & home technologies welcomes you to our tradition of excellence! In choosing a quadra-fire appliance, you have our assurance of commitment to quality, durability, and performance. This commit...

  • Page 3

    Page 3 march 27, 2008 4100-i act wood insert 250-7201 rev d r safety & overview of appliance dimensions ----------------------------------------------------- 4 minimum clearances to combustibles ------------------ 5 listings ---------------------------------------------------------- 6 chimney height...

  • Page 4: Dimensions

    4100-i act wood insert page 4 march 27, 2008 r 250-7201 rev d dimensions top view side view front view 20-7/8" (530mm) 30 o 10-7/8" (276mm) 21-5/8" (549mm) 7-7/8" (200mm) 16-1/4" (413mm) cl 24" (610mm) 30" (762mm) 12-1/8" (308mm) 9-5/16" (135mm) 45-3/4" (1162mm) a b 30-7/8" (784mm) 44-3/4” (1137mm) ...

  • Page 5

    Page 5 march 27, 2008 4100-i act wood insert 250-7201 rev d r hearth extension a b c d f e insert sidew all maximum mantel depth - 10" (254mm) fascia or trim mantel thermal protection usa & canada usa canada a sidewall to stove 15" (381mm) 15" (381mm) b mantel to stove 26" (660mm) 23" (584mm) c top ...

  • Page 6

    4100-i act wood insert page 6 march 27, 2008 r 250-7201 rev d avoid fire: to ensure that insulation or any other com- bustible material does not contact the chimney, a chimney inside the house must have at least 2 inches (51mm) of air space clearance around the chimney. A chimney outside the house m...

  • Page 7

    Page 7 march 27, 2008 4100-i act wood insert 250-7201 rev d r if installing this model to a masonry chimney, always be sure the chimney is in good condition and that it meets the minimum standards of the national fire protection association (nfpa) standard 211. A factory built chimney must be 6 inch...

  • Page 8

    4100-i act wood insert page 8 march 27, 2008 r 250-7201 rev d floor ceiling caulk floor (second story) non-combustible firestopping material minimum 1 inch (25mm) clearance from exterior chimney to sheathing firestopping 2 inch (51mm) a chimney must be the required height above the roof or other obs...

  • Page 9

    Page 9 march 27, 2008 4100-i act wood insert 250-7201 rev d r 1. An outside air inlet must be provided for combustion and must remain clear of leaves, debris, ice and/or snow. It must be unrestricted while unit is in use to prevent room air starvation which can cause smoke spillage and an inability ...

  • Page 10

    4100-i act wood insert page 10 march 27, 2008 r 250-7201 rev d masonry fireplace using direct-connect method refer to: clearances to combustibles on page 5, canadian installation requirements on page 12, hearth requirements on page 5 and zero clearance adjustable support kit on page 16. Figure 10a -...

  • Page 11

    Page 11 march 27, 2008 4100-i act wood insert 250-7201 rev d r factory-built zero clearance fireplace (usa installations only) the quadra-fire 4100-i insert is listed to ul 1482 standard and is approved for installation into listed factory-built zero clearance fi replaces listed to ul 127 conforming...

  • Page 12

    4100-i act wood insert page 12 march 27, 2008 r 250-7201 rev d leveling bolts sheet metal shims place under leveling bolts and slide insert into place leveling bolt reach between side of insert and outer skin cut-out view this product shipped with two leveling bolts, and two sheet metal guides for e...

  • Page 13

    Page 13 march 27, 2008 4100-i act wood insert 250-7201 rev d r securing liner to chimney ring there are two options to secure the liner to the chim- ney ring: see figure 13a. Option one: if there is enough room on the top of the insert to work, hand bend the two tabs upward 90°. Secure the liner wit...

  • Page 14

    4100-i act wood insert page 14 march 27, 2008 r 250-7201 rev d panel set and cast trim set 1. Remove contents from box being careful not to scratch or damage cast trim pieces. 2. Lay the panel set face down on protective covering to prevent scratching the painted surface. 3. Secure panel set togethe...

  • Page 15

    Page 15 march 27, 2008 4100-i act wood insert 250-7201 rev d r blower cord location & blower control box with switch remove bolt remove bolt remove 4 screws, lift motor from housing this insert comes standard with a blower, installed at the factory with blower cord on right side of insert (as you fa...

  • Page 16

    4100-i act wood insert page 16 march 27, 2008 r 250-7201 rev d zero clearance adjustable trim support two sizes: 9”d x 45”w and 12”d x 50”w, both 2” to10” height adjustment included in kit: ( 1) trim top, (1) trim front, (2) trim sides, double-sided tape (already installed) tools needed: phillips he...

  • Page 17: Operation

    Page 17 march 27, 2008 4100-i act wood insert 250-7201 rev d r wood selection and storage b urn only dry seasoned wood. Dry, well-seasoned wood will not only minimize the chance of creosote formation but will give you the most effi cient heat output. Even dry wood contains at least 15% moisture by w...

  • Page 18

    4100-i act wood insert page 18 march 27, 2008 r 250-7201 rev d 1 . Initial (cold) startup: leave fan off until your insert is hot and a good coal bed is established, approximately 30 minutes after fuel is lit. 2. High burn setting: the fan may be left on throughout the burn. 3. Medium low or medium ...

  • Page 19

    Page 19 march 27, 2008 4100-i act wood insert 250-7201 rev d r start-up air control primary air control figure 19a open - push in close - pull out burning process in recent years there has been an increasing concern about air quality. Much of the blame for poor air quality has been placed on the bur...

  • Page 20

    4100-i act wood insert page 20 march 27, 2008 r 250-7201 rev d maintenance care and cleaning of plated surfaces important: you must clean all the fi ngerprints and oils from the plated surfaces before fi ring the insert for the fi rst time. Use warm soapy water and a soft rag, glass cleaner and a pa...

  • Page 21

    Page 21 march 27, 2008 4100-i act wood insert 250-7201 rev d r 2 6-1/8" 2-1/4" 1 1 2 2 3 4 4 4 4 4 4 4 4 4 4 6 6 4 4 5 5 5 brick replacement instructions the fi rebox is lined with high quality fi rebrick which has excep- tional insulating properties. There is no need for a grate, simply build a fi ...

  • Page 22

    4100-i act wood insert page 22 march 27, 2008 r 250-7201 rev d exploded views 5.0" 14.0" 10.0" 21-1/2" r5" ceramic blanket figure 22c 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 18 17 20 19 item description item description item description 1 ashcatcher 8 baffl e, fiberboard 15 flue tab 2 blower, 180 cfm...

  • Page 23

    Page 23 march 27, 2008 4100-i act wood insert 250-7201 rev d r important: this is dated information. The most current information is located on the quadra-fire web site at www. Quadrafi re.Com. When ordering, supply serial and model numbers to ensure correct part. Service parts and accessories item ...

  • Page 24

    4100-i act wood insert page 24 march 27, 2008 r 250-7201 rev d 27 25 30 29 31 23 20 21 22 28 24 item # part description alphabetical order sku figure 24a accessories part no. Cast trim set, matte black, 5 pc 811-0930 panel set standard, 30-1/2” h x 44-3/4” w (order cast trim separately) 831-2010 pan...

  • Page 25

    Page 25 march 27, 2008 4100-i act wood insert 250-7201 rev d r date of service performed by description of service service and maintenance log.

  • Page 26: Consumer’S Notes

    4100-i act wood insert page 26 march 27, 2008 r 250-7201 rev d consumer’s notes.

  • Page 27: Lifetime Warranty

    Page 27 march 27, 2008 4100-i act wood insert 250-7201 rev d r lifetime warranty limited lifetime warranty the hearth & home technologies limited lifetime warranty guarantees that the following components will work as designed for the life- time of the stove or hearth & home technologies will repair...

  • Page 28

    R march 27, 2008 page 28 • do not discard this manual. • important operating and maintenance instructions included. • read, understand and follow these instruci- tons for safe installation and operation. • leave this manual with party responsible for use and operation. Caution this product may be co...