  • Page 1

    R www.Quadrafire.Com 7047-148c december 20, 2011 owner’s manual installation and operation model: 51i-acc 5100-i acc wood insert automatic combustion control (acc) do not discard this manual caution • important operating and maintenance instructions included. • leave this manual with party responsib...

  • Page 2: Caution:

    Page 2 7047-148c december 20, 2011 r 51i acc wood insert listed room heater, solid fuel type. "for use with solid wood fuel only." also for use in mobile home. Prevent house fires install and use only in accordance with manufacturer's installation, venting and operating instructions. Contact your lo...

  • Page 3

    December 20, 2011 7047-148c page 3 51i acc wood insert r congratulations...............................................................2 sampleofsafety/serialnumberlabel...........................2 warrantypolicy...............................................................4-5 section 1: listing an...

  • Page 4

    Page 4 7047-148c december 20, 2011 r 51i acc wood insert 4021-645c 12-29-10 page 1 of 2 hearth & home technologies inc. Limited lifetime warranty hearth & home technologies inc., on behalf of its hearth brands (”hht”), extends the following warranty for hht gas, wood, pellet, coal and electric heart...

  • Page 5

    December 20, 2011 7047-148c page 5 51i acc wood insert r 4021-645c 12-29-10 page 2 of 2 warranty conditions: • this warranty only covers hht appliances that are purchased through an hht authorized dealer or distributor. A list of hht authorized dealers is available on the hht branded websites. • thi...

  • Page 6

    Page 6 7047-148c december 20, 2011 r 51i acc wood insert 1 listing and code approvals thequadra-fire5100woodinsert(acc)meetstheu.S. Environmentalprotectionagency’s1990particulateemis- sionstandards. A. Appliance certification c. Glass specifications d. Btu & efficiency specifications thisstoveisequi...

  • Page 7: User Guide

    December 20, 2011 7047-148c page 7 51i acc wood insert r 2 operating instructions warning! Do not operate appliance before reading and understanding operating instructions. Failuretooperateapplianceaccordingtooperatinginstructionscouldcausefireorinjury. User guide warning hot glass will cause burns....

  • Page 8: Warning

    Page 8 7047-148c december 20, 2011 r 51i acc wood insert b. Fire safety toprovidereasonablefiresafety,thefollowingshouldbe givenseriousconsideration: 1. Install at least one smoke detector on each floor of your home to ensure your safety. They should be located away from the heating appliance and cl...

  • Page 9

    December 20, 2011 7047-148c page 9 51i acc wood insert r f. Burning process inrecentyearstherehasbeenanincreasingconcernabout airquality.Muchoftheblameforpoorairqualityhasbeen placedontheburningofwoodforhomeheating. In order to improve the situation, we at quadra-fire have developed cleaner-burning ...

  • Page 10

    Page 10 7047-148c december 20, 2011 r 51i acc wood insert h. Air controls 1. Start-up air control thestart-upaircontrolhastwoprimaryfunctions. The first function is to activate theautomatic combustion controlsystem(acc). • pushthestart-upaircontrolallthewaybackuntilitstops andthenpullforwardtothefro...

  • Page 11

    December 20, 2011 7047-148c page 11 51i acc wood insert r 3. Burn rate air control • the air supply enters at the upper front of the firebox, nearthetopoftheglassdoor. • thispreheatedairsuppliesthenecessaryfreshoxygen to mix with the unburned gases, helping to create the second,thirdandfourthcombust...

  • Page 12: Correct Position

    Page 12 7047-148c december 20, 2011 r 51i acc wood insert correct position incorrect positions j. Correct baffle & blanket placement ceramicblanketandbaffleboardarenot incontactwiththebackofthefirebox. Ceramicblanketisnotincontactwiththe backofthefireboxandnotevenwiththe baffleboardinthefront. Ceram...

  • Page 13

    December 20, 2011 7047-148c page 13 51i acc wood insert r k. Building a fire beforelightingyourfirstfireintheappliance: 1. Confirm the baffle and ceramic blanket are correctly positioned.Theyshouldbeevenwiththefronttubeand restingonalltubes. See page 12. 2. Removealllabelsfromglass. Therearemanyways...

  • Page 14

    Page 14 7047-148c december 20, 2011 r 51i acc wood insert l. Wood fuel moisture seasoned wood • cutlogstosize • splitto6inches(152mm)orlessindiameter • airdrytoamoisturecontentofnotmorethan20% - softwood-aboutninemonthstodry - hardwood-abouteighteenmonthstodry softwoods hardwoods • douglasfir • oak ...

  • Page 15

    December 20, 2011 7047-148c page 15 51i acc wood insert r n. Blower operating instructions 1. Initial (cold) startup: openbothcontrolsfullybyraising theburnrateaircontrolallthewayupuntilitstopsand pushthestart-upaircontrolbackuntilitstops. Theblower tendstocooltheappliance.Leavethebloweroffuntilthe ...

  • Page 16

    Page 16 7047-148c december 20, 2011 r 51i acc wood insert q. Opacity (smoke) opacity is the measure of how cleanly your appliance is burning. Opacityismeasuredinpercent: • 100%opacityiswhenanobjectistotallyobscuredby thesmokecolumnfromachimney,and • 0%opacitymeansthatnosmokecolumncanbeseen. As you b...

  • Page 17

    December 20, 2011 7047-148c page 17 51i acc wood insert r r. Quick start guide note: thesearegenericdrawingsandmaynotrepresent yourspecificmodel. The stove is ready for normal operation. 2 3 6 items needed for first fire: load wood add newspaper add more wood 4 add kindling light the paper 7 low hig...

  • Page 18

    Page 18 7047-148c december 20, 2011 r 51i acc wood insert • frequency: when ash is within 1-3/4 inch (44mm) of fireboxlip.Leave1/4to1/2inch(6-13mm)ofashinthe bottomofthefirebox. • by:homeowner a. Disposal of ashes • placeashesinametalcontainerwithatight-fittinglid. • theclosedcontainershouldbeplaced...

  • Page 19

    December 20, 2011 7047-148c page 19 51i acc wood insert r • frequency: asdesired • by:homeowner • cleanglasswithanon-abrasiveglasscleaner.Abrasive cleanersmayscratchandcauseglasstocrack. • ifthedepositsontheglassarenotveryheavy,normal glass cleaners work well. Heavier deposits may be removedbyusinga...

  • Page 20

    Page 20 7047-148c december 20, 2011 r 51i acc wood insert baffle blanket latch cam spacing washers baffle&blanket optionalblower chimneysystem firebrick&ashremoval door&glassassemblies doorhandle frequency monthly or afterevery cordofwood baffleandblanketplacementiscriticalto heatoutput,efficiencyan...

  • Page 21

    December 20, 2011 7047-148c page 21 51i acc wood insert r 4 troubleshooting guide withproperinstallation,operation,andmaintenanceyourwoodstovewillprovideyearsoftrouble-freeservice.Ifyoudo experienceaproblem,thistroubleshootingguidewillassistyouoraqualifiedservicepersoninthediagnosisofaproblem andthe...

  • Page 22

    Page 22 7047-148c december 20, 2011 r 51i acc wood insert 5 service parts replacement a. Glass replacement - door assembly (replace with 5mm ceramic glass only) 1. Ensurethatthefireisoutandtheapplianceiscooltothe touch. 2. Protectatableorcountertopwithpaddingortowels. Protectyourhandsandwearglovesto...

  • Page 23

    December 20, 2011 7047-148c page 23 51i acc wood insert r e. Snap disc replacement snap disc spade connectors figure 23.2 snap disc location figure 23.3 snap disc c. Glass replacement - side window (replace with 5mm ceramic glass only) d. Trim ring replacement - side window (replace with 5mm ceramic...

  • Page 24

    Page 24 7047-148c december 20, 2011 r 51i acc wood insert figure 24.3 - door handle for arched door locknut door cross section (example) latch cam spacing washers square key door handle spring handle f. Baffle removal 1.Removeallashfromthefirebox,andextinguishallhot embersbeforedisposalintoametalcon...

  • Page 25

    December 20, 2011 7047-148c page 25 51i acc wood insert r g. Tube channel assembly replacement figure 25.1 removingtubechannelassembly 1.Removetherightsidebricks(3pieces). 2.Removethebaffleprotectionchannelbyrollingforward andoutofthefirebox. 3.Locatethe2channelnutsand2channelboltsinsideof chamberan...

  • Page 26: Installer’S Guide

    Page 26 7047-148c december 20, 2011 r 51i acc wood insert 6 getting started installer’s guide a. Design and installation considerations beforeinstalling,determinethefollowing: • typeofchimneyconnectortobeused · singlewall,6inch(152mm)diameter,stainlesssteel,or ·doublewall,6inch(152mm)diameter,stainl...

  • Page 27

    December 20, 2011 7047-148c page 27 51i acc wood insert r c. Negative pressure negativepressureresultsfromtheimbalanceofairavailable fortheappliancetooperateproperly.Itcanbestrongestin lowerlevelsofthehouse. Causesinclude: • exhaustfans(kitchen,bath,etc.) • rangehoods • combustionairrequirementsforf...

  • Page 28

    Page 28 7047-148c december 20, 2011 r 51i acc wood insert recommended location marginal location location not recommended recommended location location not recommended multi-level roofs windward leeward outside termination cap figure 28.1 e. Chimney termination requirements followmanufacturer’sinstr...

  • Page 29

    December 20, 2011 7047-148c page 29 51i acc wood insert r 3 ft. (91cm) minimum less than 10 ft. (305cm) 2 ft. (61cm) 3 ft. (91cm) minimum 10 ft. (305cm) to nearest roofline 2 ft. (61cm) pitched roof these are safety requirements and are not meant to assure proper flue draft. Figure 29.1 f. 2-10-3 ru...

  • Page 30

    Page 30 7047-148c december 20, 2011 r 51i acc wood insert g. Tools and supplies needed beforebeginningtheinstallationbesurethefollowingtools andbuildingsuppliesareavailable: reciprocatingsaw framingmaterial pliers hightempcaulkingmaterial hammer gloves phillipsscrewdriver framingsquare flatbladescre...

  • Page 31

    December 20, 2011 7047-148c page 31 51i acc wood insert r 7 dimensions and clearances a. Appliance dimensions figure 31.1 top view figure 31.2 front view note: flue collar size is 6 inch (152mm) diameter (id) figure 31.4 - side view without optional offset adapter 37-7/16 in. (951mm) a b 29-1/16 in....

  • Page 32

    Page 32 7047-148c december 20, 2011 r 51i acc wood insert b. Clearances to combustibles, united states and canada (ul and ulc) note: clearances may only be reduced by means approved by the regulatory authority having jurisdiction fire risk. • complywithallminimumclearancesto combustiblesasspecified....

  • Page 33

    December 20, 2011 7047-148c page 33 51i acc wood insert r 8 chimney systems d. Masonry chimney •mustmeetminimumstandardsofnfpa211. •musthaveatleast5/8inch(16mm)fireclayliningjoined with refractory cement. (installations into a clay flue withoutastainlesssteellinermayreducedrawwhichaffects performanc...

  • Page 34

    Page 34 7047-148c december 20, 2011 r 51i acc wood insert ul 1777 insulated stainless steel liner or other approved lining system follow manufacturer’s instructions on insulation and support for zero or other non-code clearances, follow approved liner manufacturer’s specific insulation requirements:...

  • Page 35

    December 20, 2011 7047-148c page 35 51i acc wood insert r f. Prefabricated metal chimney figure 35.1 e. Metal heat circulating masonry thechimneycanbeneworexisting,masonryorprefabricated andmustmeetthefollowingminimumrequirements: •mustbeminimum6inch(152mm)insidediameterof hightemperaturechimneylist...

  • Page 36: Warning

    Page 36 7047-148c december 20, 2011 r 51i acc wood insert minimumwidthofcavityopening-front 29-1/16 738 minimumwidthofcavityopening-rear 25-1/2 648 minimumheight 20-3/4 528 minimumdepthfromfronttorear 17-9/16 446 inches millimeters thefollowing modifications offactory-built fireplaces are permissibl...

  • Page 37

    December 20, 2011 7047-148c page 37 51i acc wood insert r ovalizingroundstainlesssteellinerstoaccommodatethe linerpassingthroughthedamperregionofafireplaceisan allowableandacceptablepractice. Ensure that the ovalization is minimized to the extent requiredtofitthroughthedamper. J. Ovalizing round sta...

  • Page 38

    Page 38 7047-148c december 20, 2011 r 51i acc wood insert a. Outside air kit installation items needed for installation (not supplied) • 4 inch flex aluminum pipe, or if using alternate material, thenitshallbemadefromdurable,non-combustible,heat resistantmaterialupto350 o f.Cutthepipetotherequired l...

  • Page 39

    December 20, 2011 7047-148c page 39 51i acc wood insert r b. Securing stove pipe/liner to flue collar 1.Thereare4pre-drilledholesinthefluecollar90degrees apart.Attachthefluecollartothestovepipe/liner.Ifthe sealisquestionableusehightemperaturesealantsuch asstovemastic figure 39.1. 2.Attachgaskettobot...

  • Page 40

    Page 40 7047-148c december 20, 2011 r 51i acc wood insert d. Leveling legs 1. Removethe2screwsalreadyinstalledoneachleg. 2. Movelegstothedesiredheight . 3. Re-installthescrewstosecureinplace. Remove 2 screws from both sides. Adjust the legs up or down to level appliance. Figure 40.1 e. Securing appl...

  • Page 41

    December 20, 2011 7047-148c page 41 51i acc wood insert r f. Surround & trim kit installation 1. Laysurroundfacedownonaprotectedsurfacetopre- ventscratching. 2. Usingaphillipsheadscrewdriverattachthesidesur- roundstothetopsurroundusing2#8sheetmetalscrews providedwiththekit. Figure 41.1 3. Laythetrim...

  • Page 42

    Page 42 7047-148c december 20, 2011 r 51i acc wood insert figure 42.1 figure 42.2 figure 42.3 relocatingblowercordtoleftside 1.Removetheconvectionblowerhousingfromtheappli- ance by removing the start-up air control knob and removing the four 9/32 inchallen head bots that hold thehousingtotheapplianc...

  • Page 43

    December 20, 2011 7047-148c page 43 51i acc wood insert r figure 43.1 figure 43.2 remove control plate remove screw from bottom of housing disconnect wires to thesnap disc figure 43.3 figure 43.4 place harness under tabs figure 43.5 figure 43.6.

  • Page 44

    Page 44 7047-148c december 20, 2011 r 51i acc wood insert part no. 841-0990, size 9” x 45” and part no. Adjspt-12, size 12” x 50” double-sided tape double-sided tape screws are circled exploded view of scissors figure 44.1 thermal protection decorative tile may be installed ins t al l front trim las...

  • Page 45

    December 20, 2011 7047-148c page 45 51i acc wood insert r 8. Burn wood only. Other types of fuels may generate poisonousgases(e.G.,carbonmonoxide). 9. If unit burns poorly while an exhaust blower is on in home,(i.E.,rangehood),increasecombustionair. 10. Installationshallbeinaccordancewiththemanufact...

  • Page 46: 51I- Acc-Bk

    Page 46 7047-148c december 20, 2011 r 51i acc wood insert service parts 11/11 r wood insert stove part number list on following page. Beginning manufacturing date: july 2011 ending manufacturing date: active 1 29 28 27 26 25 24 23 22 21 20 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 51i- acc-bk se...

  • Page 47: 51I- Acc-Bk

    December 20, 2011 7047-148c page 47 51i acc wood insert r service parts 11/11 r important: this is dated information. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized deale...

  • Page 48: 51I- Acc-Bk

    Page 48 7047-148c december 20, 2011 r 51i acc wood insert service parts 11/11 r important: this is dated information. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized deale...

  • Page 49: 51I- Acc-Bk

    December 20, 2011 7047-148c page 49 51i acc wood insert r service parts 11/11 r important: this is dated information. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized deale...

  • Page 50: 51I- Acc-Bk

    Page 50 7047-148c december 20, 2011 r 51i acc wood insert service parts 11/11 r 51i- acc-bk beginning manufacturing date: july 2011 ending manufacturing date: active important: this is dated information. When requesting service or replacement parts for your appliance please provide model number and ...

  • Page 51

    December 20, 2011 7047-148c page 51 51i acc wood insert r c. Service and maintenance log date of service performed by description of service.

  • Page 52

    7047-148c december 20, 2011 page 52 r hearth & home technologies 1445 north highway colville, wa 99114 division of hni industries contact information: please contact your quadra-fire dealer with any questions or concerns. For the number of your nearest quadra-fire dealer, log onto www.Quadrafire.Com...