    Important safety notes: 1) when installing your stove, particular attention should be paid to fire protection. If this room heater is not properly installed, a house fire may result. To reduce the risk of fire, follow the installation instructions. Contact local building, fire officials or authority...

  • Page 2: Caution

    5700 act wood stove page 2 september 1, 2008 r 250-7090e and welcome to the quadra-fire family ! H earth & home technologies welcomes you to our tradition of excellence! In choosing a quadra-fire appliance, you have our assurance of commitment to quality, durability, and perfor- mance. This commitme...

  • Page 3

    Page 3 september 1, 2008 5700 act wood stove r 250-7090e table of contents listings & safety cautions.............................................4 installation materials needed ........................................4 venting system overview..............................................4 dimension...

  • Page 4

    5700 act wood stove page 4 september 1, 2008 r 250-7090e listings & safety cautions these installation instructions describe the installation and opera- tion of the quadra-fire 5700 woodstove. This stove meets the u.S. Environmental protection agency’s 1990 particulate emission standards. The 5700 i...

  • Page 5

    Page 5 september 1, 2008 5700 act wood stove r 250-7090e dimensions shown with ash removal system accessory cl 26-5/8" (676mm) 10-1/16" (256mm) 13-5/16" (338mm) 21-1/16" (535mm) 14-15/16" (379mm) 11.0" (279mm) 17-1/8" (494mm) 19-7/16" (494mm) 24.0" (610mm) 38-3/4" (984mm) back of stove to glass 13-1...

  • Page 6

    5700 act wood stove page 6 september 1, 2008 r 250-7090e clearances to combustibles (ul and ulc) a b c d backwall / sidewall e f e f corner installation g h * 90° off top up & out ceiling clearance stove to ceiling clearance c d alcove top view minimum clearances to combustible materials in inches a...

  • Page 7

    Page 7 september 1, 2008 5700 act wood stove r 250-7090e floor protection 16" from glass 8" usa fuel loading door 3-3/16" 4-13/16" 44-9/16" minimum 33-5/8" minimum canada 203mm (8") 203mm (8") 203mm (8") 457mm (18") 1387mm (54-9/16") minimum 1083mm (42-5/8") minimum 52-13/16 in. 33-5/8 in . 44-7/8 i...

  • Page 8

    5700 act wood stove page 8 september 1, 2008 r 250-7090e r = x t 1 k r = x t 1 k x 12 k-factor is given with a required thickness (t) in inches: k-factor is given with a required thickness (t) in inches: r-factor is given with a required thickness (t) in inches: r = r x t r-value given - no conversi...

  • Page 9

    Page 9 september 1, 2008 5700 act wood stove r 250-7090e to be sure that your quadra-fire stove burns properly, the chimney draft (static pressure) should be approximately -.10” water column (w.C.) during a high burn and -.04” w.C. During a low burn, measured 6” (152mm) above the top of the stove af...

  • Page 10

    5700 act wood stove page 10 september 1, 2008 r 250-7090e figure 6 there are two separate and different parts to a flue system: the chimney connector and the chimney itself. A. Single wall connector or stove pipe. This must be at least 24 gauge mild steel or 26 gauge blue steel. The sections must be...

  • Page 11

    Page 11 september 1, 2008 5700 act wood stove r 250-7090e floor protector thimble, 12" (305mm) of brick ceiling joist combustible wall 1" (25mm) clearance airtight cleanout door fireclay flue liner with air space sheathing eave 1" (25mm) clearance with firestop rafter flashing concrete cap figure 11...

  • Page 12

    5700 act wood stove page 12 september 1, 2008 r 250-7090e first, make the frame for the thimble, ensuring it is no smaller than 14" (356mm) square, to maintain a 2" (51mm) air space around the chimney section. Attach the wall spacer to the chimney side of the frame. Then insert the frame into the op...

  • Page 13

    Page 13 september 1, 2008 5700 act wood stove r 250-7090e important! Follow the manufacturer’s installation instructions and maintain the manufacturer’s specified clearance distances. * floor protector chimney connector combustible ceiling combustible wall insulated " t " flashing listed cap maintai...

  • Page 14

    5700 act wood stove page 14 september 1, 2008 r 250-7090e spark arestor cap roof flashing storm collar joist shield/firestop doublewall connector pipe outside air kit connector floor protector outside air floor vent 1. An outside air inlet must be provided for combustion and must remain clear of lea...

  • Page 15

    Page 15 september 1, 2008 5700 act wood stove r 250-7090e 1. Place protective pad or stove pallet on floor. 2. Lay body of stove on its back on protective pad or pallet. 3. Remove ash removal system top and bottom cover plates by loosening nuts under stove. Discardbothplates . Ash removal system (ar...

  • Page 16

    5700 act wood stove page 16 september 1, 2008 r 250-7090e pedestal model 1 place protective pad or stove pallet on floor. 2. Lay body of stove on its back on protective pad or pallet. 3. Loosen screws on adapter and slide pedestal over adapter on bottom of stove 4. Line up holes in sides of pedestal...

  • Page 17

    Page 17 september 1, 2008 5700 act wood stove r 250-7090e blower speed control blower mounting flange outer skin installation of optional blower, part 831-1701 the blower is shipped fully assembled and ready for installation. Note: when the speed control is turned clockwise, it will click on to high...

  • Page 18

    5700 act wood stove page 18 september 1, 2008 r 250-7090e front cover side cover (2) 4 in. Flex line (not included) outside air termination cap (contains rodent screen) flex flange outside air kit installation front cover side cover (2) 4 in. (102mm) flex line (not included) flex flange outside air ...

  • Page 19

    Page 19 september 1, 2008 5700 act wood stove r 250-7090e start-up air control primary air control burning process i nrecentyearstherehasbeenanincreasingconcernaboutair quality. Much of the blame for poor air quality has been placed on the burning of wood for home heating. In order to improve the si...

  • Page 20

    5700 act wood stove page 20 september 1, 2008 r 250-7090e note: these are approximate settings, and will vary with type of wood or chimney draft. Due to altitude and other environmental circumstances, this operation information is a guideline only. Similar burn rates may be obtained using other sett...

  • Page 21

    Page 21 september 1, 2008 5700 act wood stove r 250-7090e opacity this is the measure of how cleanly your stove is burning. Opacity is measured in percent; 100% opacity is when an object is totally obscured by the smoke column from a chimney, and 0% opacity means that no smoke column can be seen. As...

  • Page 22

    5700 act wood stove page 22 september 1, 2008 r 250-7090e maintenance and glass care disposal of ashes ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be placed on a noncombustible floor or on the ground, well away from all combustible mater...

  • Page 23

    Page 23 september 1, 2008 5700 act wood stove r 250-7090e brick replacement instructions use part 832-0550 when ordering individual brick provide brick dimension or copy this page and mark the brick you need and take it to your authorized dealer. 3 3 3 3 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 7 4 4 2 2...

  • Page 24

    5700 act wood stove page 24 september 1, 2008 r 250-7090e figure 24c - baffle with ceramic blanket on top. Allen wrench on retainer bolt first tube has larger holes figure 24b - allen wrench on retainer bolt. Door handle assembly 1. Remove all ash from the firebox, and extinguish all hot embers befo...

  • Page 25

    Page 25 september 1, 2008 5700 act wood stove r 250-7090e accessories appliance part description part no. Ash removal cast door assembly 831-1671 ash removal firebox seal plate assy 832-3110 ash removal grate 832-2980 baffle, fiberboard 832-3430 blanket, ceramic, 1 inch thick, 20-1/8 in. X 20-1/8 in...

  • Page 26

    5700 act wood stove page 26 september 1, 2008 r 250-7090e 20-1/8 in. 20-1/8 in. Ceramic blanket 1 2 3 4 5 6 7 8 9 10 11 12 item part name 1 air control rods 2 ash removal grate 3 ash pan 4 ash removal door 5 baffle, fiberboard 6 blower assembly 7 ceramic blanket 8 door assembly 9 door handle assembl...

  • Page 27

    Page 27 september 1, 2008 5700 act wood stove r 250-7090e date of service performed by description of service service and maintenance log.

  • Page 28

    5700 act wood stove page 28 september 1, 2008 r 250-7090e date of service performed by description of service service and maintenance log (cont’d).

  • Page 29

    Page 29 september 1, 2008 5700 act wood stove r 250-7090e homeowner’s notes.

  • Page 30

    5700 act wood stove page 30 september 1, 2008 r 250-7090e warranty policy hearth & home technologies limited warranty hearth & home technologies (“hht”) and its respective brands extends the following warranty for hht gas, wood, pellet and electric appliances purchased from an authorized hht dealer ...

  • Page 31

    Page 31 september 1, 2008 5700 act wood stove r 250-7090e hht’s obligation under this warranty does not extend to damages resulting from: (1) installation, operation or main- tenance of the appliance not in accordance with the installation instructions; operating instructions and the listing agent i...

  • Page 32

    Page 32 september 1, 2008 250-7090e r • do not discard this manual. • important operating and maintenance instructions included. • read, understand and follow these instruci- tons for safe installation and operation. • leave this manual with party responsible for use and operation. Caution this prod...