    This appliance may be installed in an aftermarket, permanently located, manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with the type of fuel indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certi- fie...

  • Page 2

    March 4, 2002 page 2 30211c dv400s direct vent room heater r aladdin hearth products welcomes you to our tradition of excellence! In choosing a quadra-fire appliance, you have our assurance of commitment to quality, durability, and performance. This commitment begins with our research of the market,...

  • Page 3

    Dv400s direct vent room heater march 4, 2002 page 3 30211c r table of contents safety precautions 4 listings and code approvals 5 ratings label 5 description of the dv400s room heater 6 heater system components 7 clearances 8 termination 9 a. Horizontal termination 10-13 b. Vertical termination 14-1...

  • Page 4

    March 4, 2002 page 4 30211c dv400s direct vent room heater r 1. Please read these installation instructions completely before beginning installation procedures. Failure to follow them could cause an appliance malfunction resulting in serious injury and/or property damage. 2. Due to high temperatures...

  • Page 5

    Dv400s direct vent room heater march 4, 2002 page 5 30211c r dv400s direct vent gas serial label part no. 250-5910 - beginning serial # 000,000 - size: 7.25" x 7.25" adhesive foil/black letters on silver/slit back do not remove this label / ne pas enlever l’Étiquette made in u.S.A. / fait aux États-...

  • Page 6

    March 4, 2002 page 6 30211c dv400s direct vent room heater r description of the heater system the dv400s is a direct vent room heater. Combustion air is supplied from outside, not from inside the house as with other types of heaters. Typical assembly the installation of this quadra-fire dv400s syste...

  • Page 7

    Dv400s direct vent room heater march 4, 2002 page 7 30211c r 839-0710 dv400s, matte black, ng 844-0150 fan kit, bk95, var. Speed, thermostat “on/off” 844-0140 decorative glass accent - gold, dt6g 844-7850 warming shelf, matte black (pr.) 844-7950 warming shelf bracket - w/mitten rod, black (pr.) 844...

  • Page 8

    March 4, 2002 page 8 30211c dv400s direct vent room heater r figure 1 minimum clearances to combustibles the following clearances to combustibles must be main- tained: minimum clearances to the floor - 0" back of unit to wall - 6” sides of unit to wall - 6 base of the unit to ceiling - 72". Minimum ...

  • Page 9: Termination

    Dv400s direct vent room heater march 4, 2002 page 9 30211c r termination four types of termination are possible for this heater: horizontal, vertical, existing masonry or existing class a class a metal chimney vertical flat ceiling horizontal termination cathedral ceiling common installations.

  • Page 10

    March 4, 2002 page 10 30211c dv400s direct vent room heater r 16' max. 15' max. Venting can only terminate within this area. 2' min. 10' max. 15" min. 4' 29" 59 1 / 2 "* * minimum vent height (center) (see note) note: a horizontal run of vent must have a 1/4" rise for every 1 ft. Of run towards the ...

  • Page 11

    Dv400s direct vent room heater march 4, 2002 page 11 30211c r a b c f g a v k j n v = vent terminal a = air supply inlet openable fixed closed v v v e d b l v h m = area where terminal is not permitted i a fig. 3 - horizontal termination requirements a. *12” (30cm) minimum: clearance above grade, ve...

  • Page 12

    March 4, 2002 page 12 30211c dv400s direct vent room heater r note: for buildings with vinyl siding, a vinyl siding standoff should be installed between the vent cap and the exterior wall. Attach the vinyl siding standoff to the horizontal vent termination. The vinyl siding standoff prevents excessi...

  • Page 13

    Dv400s direct vent room heater march 4, 2002 page 13 30211c r the dura-vent gs is unitized and twist-locks together. For the twist-lock procedure, consult figure 5 and do the following: (1) four indentations, located on the female ends of pipes and fittings, are designed to slide straight onto the m...

  • Page 14

    March 4, 2002 page 14 30211c dv400s direct vent room heater r b. Vertical termination. The following figures are the maximum distances from the top of the unit, as well as the minimum air space clearances that must be maintained: maximum straight unsupported rise - 25'; maximum height - 40' from the...

  • Page 15

    Dv400s direct vent room heater march 4, 2002 page 15 30211c r to attach a straight section to the top of the heater, with the female end down, slide that pipe over the outer collar on the heater while the vent inner slips into the flue of the heater. Maintain minimum 1" clearances or greater around ...

  • Page 16

    March 4, 2002 page 16 30211c dv400s direct vent room heater r c. Existing masonry chimney installation this installation is subject to local jurisdic- tion. Some codes may require the use of another liner for intake air. If so, the 4” aluminum liner should be inside a 6” ul 181 listed liner. This he...

  • Page 17

    Dv400s direct vent room heater march 4, 2002 page 17 30211c r figure 12 masonry termination rigid flashing (attached to chimney with screws with silicone sealant underneath) silicone sealant vta 6" liner (optional) before installing the liner system, the chim- ney passageway should be cleaned and ex...

  • Page 18

    March 4, 2002 page 18 30211c dv400s direct vent room heater r figure 13 retro-fit to metal chimney vertical termination cap vertical termination adapter ul1777 listed 4'' gas vent flex liner existing class a metal chimney (6'' min. Diameter) duravent gs vent sections when using an existing class a m...

  • Page 19

    Dv400s direct vent room heater march 4, 2002 page 19 30211c r gas line installation the valve is located near the lower right rear corner of the appliance. (see figure 14.) install the gas supply line to the valve. For ease of installation of the unit to the supply line, a flexible connector and man...

  • Page 20

    March 4, 2002 page 20 30211c dv400s direct vent room heater r high altitude installation for u.S. Installation, units are tested and approved for elevations from 0-2000 feet. When installing this unit at an elevation above 2000 feet, it may be necessary to decrease the input rating by changing the e...

  • Page 21

    Dv400s direct vent room heater march 4, 2002 page 21 30211c r optional accessories a. Optional fan blower installation: 1. Remove the knockout plate from the backshield of the dv400s by prying out on the plate and clip or break the tabs that hold it in place. See figure 1 below. 2. Remove the tape f...

  • Page 22

    March 4, 2002 page 22 30211c dv400s direct vent room heater r warning! Electrical grounding instructions this appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a prop- erly grounded three-prong receptacle. Do not cu...

  • Page 23

    Dv400s direct vent room heater march 4, 2002 page 23 30211c r figure 17 - removal of sealed glass firebox entry a. Removing the front face. 1. Loosen the thumb screw from the bottom of the unit that holds the front face in position. See figure 16. 2. Carefully lift the front face up and pull the bot...

  • Page 24

    March 4, 2002 page 24 30211c dv400s direct vent room heater r before operating this heater, please review the safety precau- tions given on page 4 as well as the items listed below: 1. Check to make sure the logs are securely in place and the rock wool, and ember chunks have all been placed correctl...

  • Page 25

    Dv400s direct vent room heater march 4, 2002 page 25 30211c r 1. Turn rocker switch to off or the wall thermostat to lowest setting if your unit is so equipped. 2. Turn off all electric power to the appliance if service is to be performed. 3. Turn gas control clockwise to “off”. 7. Smell for gas, in...

  • Page 26

    March 4, 2002 page 26 30211c dv400s direct vent room heater r figure 25 air shutter adjustment note: allow the unit to cool before replacing the front face. Figure 24 on/off switch caution: during the initial purging and sub- sequent lightings, never allow the gas valve control knob to remain depres...

  • Page 27

    Dv400s direct vent room heater march 4, 2002 page 27 30211c r cleaning the burner and control compartment keep the burner compartment clean. Brush this area with a clean, dry paint brush and vacuum at least once a year. Always turn off the gas valve and on/off switch before cleaning. Checking flame ...

  • Page 28: Trouble Shooting

    March 4, 2002 page 28 30211c dv400s direct vent room heater r trouble shooting pilot will not light 1. Is a gas shut-off valve turned on? 2. Is the valve control knob turned to “pilot” (see lighting instructions, #6, pg. 25. 3. Is the valve control knob pushed in? (see lighting instructions, pg. 25 ...

  • Page 29

    Dv400s direct vent room heater march 4, 2002 page 29 30211c r stove design many of the components within this gas stove are designed specifically for safety purposes. It is therefore imperative that only certified gas service technicians should service this appliance. Burner operation a millivolt sy...

  • Page 30

    March 4, 2002 page 30 30211c dv400s direct vent room heater r ** if any of the original wiring as supplied with the heater must be replaced, it must be replaced with type 18 ga., 105c wire, or its equivalent. Item part# description 844-8150 burner assembly 844-4250 ez thermocouple 842-0250 thermopil...

  • Page 31: Lifetime Warranty

    Dv400s direct vent room heater march 4, 2002 page 31 30211c r lifetime warranty lifetime warranty the aladdin hearth products limited lifetime warranty guarantees that the following components will work as designed for the lifetime of the stove or aladdin hearth products will repair or replace them....

  • Page 32: Attention