Quadra-Fire FireBrick qvi25fb Installer's Manual

Other manuals for FireBrick qvi25fb: Specifications

Summary of FireBrick qvi25fb

  • Page 1

    Quadra-fire • qvi-25fb • 2031-900 rev. F • 9/07 1 installers guide underwriters laboratories listed please contact your quadra-fire dealer with any questions or concerns. For the number of your nearest quadra-fire dealer, please visit www.Quadrafire.Com. Model: qvi-25fb quadra-fire, a brand of heart...

  • Page 2

    Quadra-fire • qvi-25fb • 2031-900 rev. F • 9/07 2 these units must use one of the vent systems described in the installing the appliance section of the installers guide. No other vent systems or components may be used. This gas appliance and vent assembly must be vented directly to the outside and m...

  • Page 3

    Quadra-fire • qvi-25fb • 2031-900 rev. F • 9/07 3 table of contents safety and warning information ................................................ 2 service parts lists ..................................................................... 4 section 1: approvals and codes ..............................

  • Page 4: Service Parts

    Quadra-fire • qvi-25fb • 2031-900 rev. F • 9/07 4 4 2 1 3 5 6 part number list on following page. Log set assembly service parts diagram service parts qvi-25fb 16 7 8 10 9 12 13 15 14 11.

  • Page 5

    Quadra-fire • qvi-25fb • 2031-900 rev. F • 9/07 5 service parts list qvi-25fb regulator lp 060-519 y additional service part numbers appear on following page. Item description serial # part number log set assembly logs-2031 y 1 log 1 srv2032-701 2 log 2 srv2032-702 3 log 3 srv2032-703 4 log 4 srv340...

  • Page 6: Qvi-25Fb

    Quadra-fire • qvi-25fb • 2031-900 rev. F • 9/07 6 item description serial # part number 1 valve bracket 2019-105 2 piezo ignitor 291-513 y pilot assembly ng 530-510a y pilot assembly lp 530-511a y 4 burner drop plate 2019-164 5 flexible gas connector 567-301a y 6 flex ball valve assembly 302-320a y ...

  • Page 7: Approvals and

    Quadra-fire • qvi-25fb • 2031-900 rev. F • 9/07 7 appliance certification the quadra-fire appliance models discussed in this installers guide has been tested to certification standards and listed by the applicable laboratories. Certification model: qvi-25fb laboratory: underwriters laboratories type...

  • Page 8: Getting Started

    Quadra-fire • qvi-25fb • 2031-900 rev. F • 9/07 8 2 getting started introducing the village collection gas appliances the village collection direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside....

  • Page 9

    Quadra-fire • qvi-25fb • 2031-900 rev. F • 9/07 9 figure 1. Diagram of insert and minimum appliance dimensions b 3/4” c a 3/8” fireplace top view minimum fireplace size gas access optional 3-sided surround glass assembly gas control valve rating plate electrical junction box access inlet air startin...

  • Page 10: Installing The Insert

    Quadra-fire • qvi-25fb • 2031-900 rev. F • 9/07 10 3 installing the insert step 1. Installing the vent system vent system installation precautions before starting installation of vent kits, the installer should read these instructions and the vent kit instructions to ensure that a proper vent instal...

  • Page 11

    Quadra-fire • qvi-25fb • 2031-900 rev. F • 9/07 11 ! Attach the flashing and termination cap to the top of the flexible vent pipe and set the cap in place. See figures 3 and 4. Caution: to avoid downdrafts and/or cold air problems, it is recommended to seal off the area between the termination cap a...

  • Page 12

    Quadra-fire • qvi-25fb • 2031-900 rev. F • 9/07 12 figure 3. Warning: the exhaust vent pipe must only be connected to the exhaust starting collar of the unit and the center collar of the termination cap. A 3 foot section of stainless steel flexible liner must be attached directly to the exhaust coll...

  • Page 13

    Quadra-fire • qvi-25fb • 2031-900 rev. F • 9/07 13 figure 4. Typical configuration of vent liners. Note: inspect for exhaust collar gasket to insure positive exhaust seal. Locking tab locking handle sliding plate stainless steel adapter for exhaust (must be installed) inlet air vent pipe 3 inch coll...

  • Page 14

    Quadra-fire • qvi-25fb • 2031-900 rev. F • 9/07 14 step 2. Positioning, leveling, and securing the insert • place the insert into position. • level the insert from side to side and from front to back. Use the leveling legs included with the manual bag if necessary to set each corner of the base. ! !...

  • Page 15

    Quadra-fire • qvi-25fb • 2031-900 rev. F • 9/07 15 step 5. Gas pressure requirements pressure requirements for these gas appliances are shown in the table below. Pressure natural gas propane minimum 5.0 inches 11.0 inches inlet pressure w.C. W.C. Maximum inlet 14.0 inches 14.0 inches gas pressure w....

  • Page 16

    Quadra-fire • qvi-25fb • 2031-900 rev. F • 9/07 16 ! Figure 8. Junction box installation figure 9. Fan wiring diagram warning: use of the cord supplied with the electrical junction box is required. Junction box variable speed control temperature sensor switch wht grn blk blk 110-120 vac blower blowe...

  • Page 17

    Quadra-fire • qvi-25fb • 2031-900 rev. F • 9/07 17 combustible materials must never overlap onto the front face. 1. Find the coiled low voltage wires attached to outer right side of the insert (see figure 13). 2. Disconnect the on/off switch from the low voltage wire leads, and insert the on/off swi...

  • Page 18

    Quadra-fire • qvi-25fb • 2031-900 rev. F • 9/07 18 step 9. Before lighting the appliance before lighting the appliance, be sure to do the following: remove all paperwork from the appliance. Review safety warnings and cautions • read the safety and warning information section at the beginning of this...

  • Page 19

    Quadra-fire • qvi-25fb • 2031-900 rev. F • 9/07 19 step 10. Lighting the appliance standing pilot ignition a. This appliance (standing pilot version) has a pilot that must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. Before lighting smell all around the appli- a...

  • Page 20

    Quadra-fire • qvi-25fb • 2031-900 rev. F • 9/07 20 4 maintaining and servicing your appliance appliance maintenance although the frequency of servicing and maintenance will depend on use and the type of installation, you should have a qualified service technician perform an appliance check- up at th...

  • Page 21

    Quadra-fire • qvi-25fb • 2031-900 rev. F • 9/07 21 troubleshooting with proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qualified service person in the diagnosis of...

  • Page 22

    Quadra-fire • qvi-25fb • 2031-900 rev. F • 9/07 22 symptom possible cause corrective action 4. Frequent pilot outage problem. A. Pilot flame may be too high or too low, or blowing (high), causing pilot safety to drop out. Clean and adjust the pilot flame for maximum flame impingement on thermocouple...

  • Page 23: Lifetime Warranty

    Quadra-fire • qvi-25fb • 2031-900 rev. F • 9/07 23 lifetime warranty limited lifetime warranty the hearth & home technologies limited lifetime warranty guarantees that the following components will work as designed for the lifetime of the stove or hearth & home technologies will repair or replace th...