Quadra-Fire GARNET-D-CSB Owner's manual

Other manuals for GARNET-D-CSB: Owner's Manual
Manual is about: GARNET-T DIRECT VENT ROOM HEATER

Summary of GARNET-D-CSB

  • Page 1

    R garnet-t direct vent room heater owner’s manual installation and operation model: garnet-mbk garnet-d-mbk garnet-d-pmh garnet-d-csb o-t o-t l tested and listed by portland oregon usa omni-test laboratories, inc. C us do not discard this manual caution • important operating and maintenance instruct...

  • Page 2

    Page 2 and welcome to the quadra-fire family ! Hearth & home technologies welcomes you to our tradition of excellence! In choosing a quadra-fire appliance, you have our assurance of commitment to quality, durability, and performance. This commitment begins with our research of the market, including ...

  • Page 3

    Page 3 - table of contents - section 1: listing and code approvals a. Appliance certifi cations ......................4 b. Glass specifi cations ............................4 c. Btu specifi cations ..............................4 d. High altitude installations ....................4 e. Non-combustibl...

  • Page 4

    Page 4 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 1 listing and code approvals the product is listed to ansi standards for “vented gas appliance heaters” and applicable sections of “gas burning heating appliances for manufactured homes and recre- ational vehicles” and "gas fired appliances for...

  • Page 5

    Page 5 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 note: the following requirements reference various massachusetts and national codes not contained in this document. For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or i...

  • Page 6

    Page 6 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 2 getting started check building codes prior to installation. • installation must comply with local, regional, state and national codes and regulations. • consult local building, fi re offi cials or authorities having jurisdiction about restric...

  • Page 7

    Page 7 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 3 appliance location and clearances a. Selecting appliance location note: · illustrations refl ect typical installations and are for design purposes only. · illustrations/diagrams are not drawn to scale. · actual installation may vary due to in...

  • Page 8

    Page 8 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 4 termination locations a. Vent termination minimum clearances figure 4.2 multiple vertical termination figure 4.1 termination clearances figure 4.3 specifi es minimum vent heights for various pitched roofs. Figure 4.3 minimum height from roof ...

  • Page 9

    Page 9 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 figure 4.4 v = vent terminal x = air supply inlet = area where terminal is not permitted a = 12 inches ............. Clearances above grade, veran- da, porch, deck or balcony b = 12 inches ............ Clearances to window or door that may be o...

  • Page 10

    Page 10 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 5 vent information a. Venting components b. Use of elbows in order to comply with applicable codes and product warranties, use only following venting components: • hearth & home technologies (hht) • simpson dura-vent • selkirk direct-temp • am...

  • Page 11

    Page 11 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 d. How to use the vent graph e. Venting guidelines figure 5.2 vertical distance from appliance to 90° elbow exceptions for horizontal installations: t he maximum horizontal vent run is 30 in. (762mm). The maximum horizontal vent run with a 45°...

  • Page 12

    Page 12 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 female locking lugs male locking lugs step 1. Determine the desired location of the appliance. Check to ensure that wall studs or roof rafters are not in the way when the venting system is attached. If this is the case, you may want to adjust ...

  • Page 13

    Page 13 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 note: (1) installation requires a minimum of 6 in. (152mm) horizontal run of vent with a 1/4 in. (6mm) rise run towards the termination. Each 1 ft. (305mm) of horizontal venting must include a 1/4 in. (6mm) rise. Never allow the vent to run do...

  • Page 14

    Page 14 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 fold strap here wall thimble cover/ceiling firestop as required by local jurisdiction 1/4 in. (6mm) strap sheet metal screw wall thimble figure 5.9 wall thimble cover wall thimble vinyl siding standoff with siding beneath removed screws bolt h...

  • Page 15

    Page 15 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 step 1. Check the installation instructions for required 1 in. (25mm) clearances (air space) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafters, or other nearby combustible surfaces. See page 17, figure 5.16...

  • Page 16

    Page 16 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 step 4. Assemble the desired lengths of pipe and elbows necessary to reach from the appliance up through the round support box. Ensure that all pipe and elbow connections are in their fully twist-locked position. Assemble as instructed. Step 5...

  • Page 17

    Page 17 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 step 8. Slip the storm collar over the pipe, and push it down to the top of the flashing ( figure 5.15). Use non-hardening sealant above and below the joint between the storm collar and the pipe. Optional high wind termination cap secure flash...

  • Page 18

    Page 18 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 2. Cathedral ceiling level cathedral ceiling support box 2 in. (51mm) min. Below finished ceiling cut hole 1/8 in. (3mm) greater in size than pattern of support box as it is projected onto roof line figure 5.17 figure 5.18 step 1. Follow insta...

  • Page 19

    Page 19 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 high wind termination cap sheet metal screws drill four 1/8 in. (3mm) diamater holes figure 5.22 figure 5.23 step 4. Pass the flex pipe down through the center of the chimney system, and center the top adapter on the top of the chimney pipe. D...

  • Page 20

    Page 20 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 4. Existing masonry chimney figure 5.24 type c - up & out installation type a & b - co-axial to co-linear chimney liner termination cap co-axial to co-linear connector 25 ft. (8m) of 3 in. (76mm) flex liner exhaust section pipe length optional...

  • Page 21

    Page 21 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 10 in. X 10 in. (254mm x 254mm) framed opening in wall studwall masonry chimney retro connector (4) masonry bolts (not included) wall thimble cover figure 5.25 step 1. Before cutting any holes, assemble the desired sections of direct vent pipe...

  • Page 22

    Page 22 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 high wind termination cap top adaptor (3) sheet metal screws flashing step 9. Attach the flex to the retro connector. Use three sheet metal screws to attach the flex liner to the connector ( figure 5.29). Mount the retro connector to the mason...

  • Page 23

    Page 23 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 3/4 3/4 3/4 before you begin: review the venting confi gurations in figures a, b and c on the next page. H. Slim line wall thimble 1. Assembling slim line trim ring and heat shield 2. Installing slim line trim ring and heat shield figure 5.31 ...

  • Page 24

    Page 24 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 fig. A 90 degree elbow fig. C minimum clearance figure 5.33 fig. B 45 degree elbow center line trim ring heat shield over top half of pipe termination cap wall thimble minimum of 6 in. (152 mm) of pipe through wall interior wall 2 in. (51mm) c...

  • Page 25

    Page 25 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 6 gas information a. Fuel conversions before making gas connections ensure that the appliance being installed is compatible with the available gas type. Any natural or propane gas conversions necessary to meet the appliance and locality needs ...

  • Page 26

    Page 26 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 a b c mounting screws pressure regulator tower diaphragm figure 6.5 turn control knob to the off position, ensure that gas supply to the valve has been turned off. Using a torx th20, or slotted screwdriver, remove the three pressure reg- ulato...

  • Page 27

    Page 27 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 b. Gas pressures if the pressure is not suffi cient, ensure: 1) the piping used is large enough. 2) the supply regulator is adequately adjusted. 3) that the total gas load for the residence does not exceed the amount supplied. The supply regul...

  • Page 28

    Page 28 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 • a small amount of air will be in the gas supply lines. When fi rst lighting appliance it will take a short time for air to purge from lines. When purging is complete the appliance will light and operate normally. Air only needs to be purged ...

  • Page 29

    Page 29 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 7 electrical information a. Recommendation for wire c. Standing pilot ignition system wiring see b5 below for recommended maximum lead length (two wire) when using wall thermostat/switch. B. Connecting to the appliance this appliance does not ...

  • Page 30: Caution

    Page 30 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 figure 7.1 caution label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Shock hazard. • replace damaged wire with type 105 o c rated ...

  • Page 31

    Page 31 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 8 appliance setup a. Remove shipping materials remove shipping materials from inside or underneath the fi rebox. B. Leg leveling system figure 8.1 thread allen bolts through nuts until fl ush. The allen bolts and nuts are included in the compo...

  • Page 32

    Page 32 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 d. Accessories install approved accessories per instructions included with accessories. Refer to section 12 for appropriate accesso- ries. Shock or fi re risk. Use only optional accessories approved for this appliance. • using non-listed acces...

  • Page 33

    Page 33 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 h. Blower installation 11 10 kit contents: 1 - blower mounted in housing 2 - speed control knob 3 - pal nut 4 - ceramic snap disc 5 - speed control (rheostat) 6 - wire harness (attached to blower) 7 - 12 screws 8 - 12 inch glass tape 9 - 1 zip...

  • Page 34

    Page 34 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 figure 8.12 install the snap disc. A snap disc bracket is located in the appliance's component bag. Bend the two spade teminals on the snap disc from a horizontal to a verti- cal position. Insert the snap disc through the hole in the snap disc...

  • Page 35

    Page 35 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 figure 8.15 blower wiring diagram fan speed control thermal disc (110 vac) power cord black bushing strain relief green black ground fan assembly black black white white white.

  • Page 36

    Page 36 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 i. Ignition module access and battery replacement figure 8.16 the ignition module is located under the appliance attached to the decorative cover. Lift off the appliance top and place it on a flat surface, with the porcelain side up to prevent...

  • Page 37

    Page 37 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 9 operating instructions a. Before lighting appliance read this entire manual prior to using the appliance. Failure to follow the instructions may result in property damage, bodily injury, or even death. Glass door must be in place when applia...

  • Page 38

    Page 38 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 c. Lighting appliance 1. Set the thermostat to lowest setting. 2. Turn off all electric power to the appliance if service is to be performed. 3. Push in gas control knob slightly and turn clockwise to "off" position. For your safety read befor...

  • Page 39

    Page 39 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 d. After appliance is lit when you light your appliance, you may notice that it pro- duces heat which does have an associated odor or smell. If you feel this odor is excessive it may require the initial three to four hour continuous burn on hi...

  • Page 40

    Page 40 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 10 troubleshooting with proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qualifi ed service person in the di...

  • Page 41

    Page 41 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 symptom possible cause corrective action 3. (continued) c. Defective valve. Turn the valve knob to the on position. Place the on/off switch in the on position. Check the millivolt meter at the thermopile terminals. The millivolt meter should r...

  • Page 42

    Page 42 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 11 maintaining and servicing your appliance although the frequency of your appliance servicing and maintenance will depend on use and the type of installation, a qualifi ed service technician should perform an appliance check-up at the beginni...

  • Page 43

    Page 43 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 inspect maintenance tasks doors 1. Inspect for scratches, dents or other damage and repair as necessary. 2. Verify no obstructions to air fl ow. 3. Verify maintenance of proper clearance to combustible household objects. Gasket seal, glass ass...

  • Page 44

    Page 44 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 12 reference materials a. Appliance dimension diagram dimensions are actual appliance dimensions. Use for reference only. For clearances refer to section 3. Figure 12.1 appliance dimensions a b f c d e location inches millimeter location inche...

  • Page 45

    Page 45 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 b. Vent components diagram figure 12.2 sl-d series vent components 4 in. (102 mm) inner pipe 6-5/8 in. (168 mm) outer pipe 9-1/4 in. (235mm) 6-1/2 in. (165mm) 6-5/8 in. (168mm) 17-24 in. (432-610mm) 11-3/4 in. (298mm) 5-3/4 in. (146mm) 6-5/8 i...

  • Page 46

    Page 46 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 c. Vent components list description hht slp m= multi pack (6) simpson dura-vent directvent pro 4” pipe length, galvanized slp4m - 4” pipe length, black slp4-bk - 6” pipe length, galvanized slp6m 46-dva-06 6” pipe length, black slp6-bk 46-dva-0...

  • Page 47

    Page 47 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 c. Vent components list (continued) * stove adaptor kit (vertical cap kit) includes 30’-4” À ex, adapters, wall thimble, masonry, zc À ashing, 991da vertical cap. Notes: 1 before cutting any holes check pipe manufacturers current instructions....

  • Page 48

    Page 48 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 d. Service parts list r garnet-t direct vent gas stove part number list on following page. Log set assembly 3 1 2 color sku no. Mfg. Dates matte black 839-1110 7/01 - 6/04 porcelain creme 839-1120 7/01 - 5/04 garnet-d-pcr 6/04 - 8/05 porcelain...

  • Page 49

    Page 49 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 d. Service parts list garnet-t important: this is dated information. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authoriz...

  • Page 50

    Page 50 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 d. Service parts list garnet-t important: this is dated information. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authoriz...

  • Page 51

    Page 51 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 garnet-t important: this is dated information. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer. Stocked at ...

  • Page 52

    Page 52 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 e. Limited lifetime warranty 4021-645c 12-29-10 page 1 of 2 hearth & home technologies inc. Limited lifetime warranty hearth & home technologies inc., on behalf of its hearth brands (”hht”), extends the following warranty for hht gas, wood, pe...

  • Page 53

    Page 53 quadra-fire • garnet-t • 7016-127 rev. I • 12/11 e. Limited lifetime warranty (continued) 4021-645c 12-29-10 page 2 of 2 warranty conditions: 7klvzduudqw\rqo\fryhuv++7dssoldqfhvwkdwduhsxufkdvhgwkurxjkdq++7dxwkrul]hgghdohuruglvwulexwru$olvwri ++7dxwkrul]hgghdohuvlvdydlodeohrqwkh++7eudqghgzhev...

  • Page 54: Your Records For Model:

    Page 54 dealership where purchased: ______________________________________ ______________________________________ _______________________________________ _______________________________________ _______________________________________ _______________________________________ dealer telephone: ________...