Quadra-Fire MT VERNON E2-C Installation Manual - Install Guide

Manual is about: MT. VERNON E2 PELLET APPLIANCE

Summary of MT VERNON E2-C

  • Page 1

    1 7080-162b october 12, 2017 mt. Vernon e2 pellet appliance model(s): mtv-e2-csb-c mtv-e2-mbk-c mtv-e2-pft-c mtv-e2-pdb-c mtv-e2-pbk-c mtv-e2-pmh-c installation manual installation & appliance set-up installer: leave this manual with party responsible for use and operation. Owner: retain this manual...

  • Page 2

    2 7080-162b october 12, 2017 mt vernon e2-c table of contents safety alert key: • danger!Indicates a hazardous situation which, if not avoided will result in death or serious injury. • warning! Indicates a hazardous situation which, if not avoided could result in death or serious injury. • caution!I...

  • Page 3

    October 12, 2017 7080-162b 3 mt vernon e2-c the quadra-fire mt. Vernon e2 pellet appliance meets the u.S. Environmental protection agency certified to comply with 2020 particulate emission standards at 0.74 g/hr epa cfr subpart aaa, using astm e2779-10, astm 2515-11 method- pellet appliance sections...

  • Page 4: Install Guide

    4 7080-162b october 12, 2017 mt vernon e2-c install guide 2 getting started marginal location: • below peak location not recommended: • not the highest point of the roof • wind loading possible multi-level roofs windward leeward recommended: outside air intake on windward side not recommended: outsi...

  • Page 5

    October 12, 2017 7080-162b 5 mt vernon e2-c • installation and use of any damaged appliance. • modification of the appliance. • installation other than as instructed by hearth & home technologies. • installation and/or use of any component part not approved by hearth & home technologies. • operating...

  • Page 6

    6 7080-162b october 12, 2017 mt vernon e2-c yes if no, why? Verified clearance to combustibles. Appliance is leveled and connector is secured to appliance. Hearth extension size/height decided. Outside air kit installed. Floor protection requirements have been met. If appliance is connected to a mas...

  • Page 7

    October 12, 2017 7080-162b 7 mt vernon e2-c figure 7.1 - top view figure 7.3 - top view with top vent adapter (tpvnt-3) and offset adapter (812-3570). 3-5/8 in (93mm) 3-5/8 in (93mm) qq 10-3/8 in (264mm) 10-3/8 in (264mm) 3-3/4 in (97mm) 4-1/8 in (104mm) 6-1/8 in (155mm) 6-1/8 in (155mm) 14 in (357m...

  • Page 8

    8 7080-162b october 12, 2017 mt vernon e2-c 28-3/4 in (730mm) 26-7/8 in (683mm) 19-9/16 in (497mm) 20 in (508mm) 29 in (738mm) 29 in (738mm) 30-5/8 in (779mm) 30-5/8 in (779mm) figure 8.3 -side view figure 8.4 - side view with top vent adapter (tpvnt-3) and offset adapter (811-0720). Figure 8.2 - fr...

  • Page 9

    October 12, 2017 7080-162b 9 mt vernon e2-c 31-1/16 in (788mm) 29-3/16 in (741mm) figure 9.1 - side view with top vent adapter (tpvnt-3) and offset adapter (812-3570). Figure 9.2 - side view with top vent adapter (tpvnt-6) and offset adapter (812-3570). Figure 9.3 - side view with top vent adapter (...

  • Page 10

    10 7080-162b october 12, 2017 mt vernon e2-c horizontal through the wall inches millimeters a back wall to appliance 2 51 b side wall to appliance 6 152 corner installation inches millimeters c walls to appliance 2 51 vertical installation inches millimeters d back wall to flue pipe 3 76 e side wall...

  • Page 11

    October 12, 2017 7080-162b 11 mt vernon e2-c usa installations: a non-combustible floor protec- tion is recommended extending beneath the flue pipe when installed with horizontal venting or under the top vent adapter with vertical installation. Canada installations: a non-combustible floor pro- tect...

  • Page 12

    12 7080-162b october 12, 2017 mt vernon e2-c c a b d note: • illustrations reflect typical installations and are for design purposes only. • i llustrations/diagrams are not drawn to scale. • actual installation may vary due to individual design preference. D. Alcove figure 12.1 *all minimums listed ...

  • Page 13

    October 12, 2017 7080-162b 13 mt vernon e2-c 4 vent information a. Venting termination minimum requirements j or k x v m i h a v g b v v a b v f v c b b e l v d v electrical service v n v n v n n v inside corner fixed closed open open fixed closed v x g g termination cap air supply inlet gas meter r...

  • Page 14

    14 7080-162b october 12, 2017 mt vernon e2-c b. Avoiding smoke and odors negative pressure, shut-down and electrical power failure to reduce the probability of back-drafting or burn-back in the pellet appliance during power failure or shut down con- ditions, it must be able to draft naturally withou...

  • Page 15

    October 12, 2017 7080-162b 15 mt vernon e2-c negative pressure results from the imbalance of air avail- able for the appliance to operate properly. It can be strongest in lower levels of the house. Causes include: • exhaust fans (kitchen, bath, etc.) • range hoods • combustion air requirements for f...

  • Page 16

    16 7080-162b october 12, 2017 mt vernon e2-c f. Equivalent feet of pipe the table below can help you calculate the equivalent feet of pipe which is a method used to determine pellet vent size. Figure 16.1. 2 ft. 2 ft. 3 ft. 2 ft. Example of 3 elbow-rear vent termination calculation pellet venting co...

  • Page 17

    October 12, 2017 7080-162b 17 mt vernon e2-c 2 in [51mm] min 6 in [152mm] min 6 in [152mm] min non-combustible hearth pad wall thimble horizontal termination cap straight out figure 17.1 figure 17.2 wall thimble illustration shows venting going in both directions. Choose which one is best for your i...

  • Page 18

    18 7080-162b october 12, 2017 mt vernon e2-c c. Through the wall & vertical - exterior firestop flashing rain cap 6 in [152mm] min non-combustible hearth pad 3 in [76mm] min clean-out cover 12 in. [305mm] min ceiling support 3 to 6 in [76 to 152mm] offset adapter 6 in. [152mm] class a chimney connec...

  • Page 19

    October 12, 2017 7080-162b 19 mt vernon e2-c e. Masonry f. Alternate masonry concrete cap non-combustible hearth pad 6 in [152mm] min airtight clean-out door sheathing 1 in [25mm] clearnance 2 in [51mm] min to combustible material flashing fireclay flue liner with airspace 1 in [25mm] clearance with...

  • Page 20

    20 7080-162b october 12, 2017 mt vernon e2-c 6 appliance set-up figure 20.3 - bolt fully extended figure 20.2 figure 20.1 a. Leg leveling system 1. Thread allen bolts through nuts until flush. Figure 20.1. The allen bolts and nuts are included in the component pack inside the appliance firebox. 2. S...

  • Page 21

    October 12, 2017 7080-162b 21 mt vernon e2-c 3 in. To 6 in. Offset adapter silicone rear exhaust outlet 3 in. To 3 in. Top vent adapter clean-out cover drill hole, 1 on each side c. Top vent adapter installation 3 to 3 inch (76-76mm) top vent adapter 3 to 6 inch (76-152mm) top vent offset adapter in...

  • Page 22

    22 7080-162b october 12, 2017 mt vernon e2-c caution logs are fragile. Use extreme care when handling or cleaning logs. Notice: due to the abrasive nature of a pellet appliance fire, the logs are not covered under warranty. Any placement variation other than shown here can cause excessive heat and s...

  • Page 23

    October 12, 2017 7080-162b 23 mt vernon e2-c f. Programmable wall thermostat installation the appliance comes standard with a wall thermostat and 25’ of wire. If you need to run more than 25’ make sure you use a continuous strand of 18 to 22 gauge thermostat wire. For optimum performance your thermo...

  • Page 24

    24 7080-162b october 12, 2017 mt vernon e2-c 7014-262b january 29, 2016 page 2 of 2 program schedule override (temporary) press or to immediately adjust the temperature. This will temporarily override the temperature setting for the current time period. The new temperature will be maintained only un...

  • Page 25

    October 12, 2017 7080-162b 25 mt vernon e2-c shock hazard. • do not remove grounding prong from plug. • plug directly into properly grounded 3 prong receptacle. • route cord away from appliance. • do not route cord under or in front of appliance. Caution g. Power cord 1. Prior to installing the powe...

  • Page 26

    26 7080-162b october 12, 2017 mt vernon e2-c 7 mobile home installation you must use a quadra-fire outside air kit for installation in a mobile home. 1. An outside air inlet must be provided for the combustion air and must remain clear of leaves, debris, ice and/or snow. It must be unrestricted whil...

  • Page 27: Mtv-E2-C

    October 12, 2017 7080-162b 27 mt vernon e2-c 8 accessory list service parts r mtv-e2-c beginning manufacturing date: july 2017 ending manufacturing date: active important: this is dated information. Parts must be ordered from a dealer or distributor. Hearth and home technologies does not sell direct...

  • Page 28

    28 7080-162b october 12, 2017 contact information hearth & home technologies 352 mountain house road halifax, pa 17032 division of hni industries please contact your quadra-fire dealer with any questions or concerns. For the number of your nearest quadra-fire dealer log onto www.Quadrafire.Com do no...