Quadra-Fire QFP 30 Operation & Maintenance Manual - Glass & Blo
QFP 30 Direct Vent Gas Fireplace
Page 38
03/21/01 #250-6120
GLASS REPLACEMENT
Replace glass with part #842-3820 ONLY, available from
your dealer.
1. Turn valve to “OFF” position to prevent start-up of
unit while door is removed.
2. Prepare a flat area to lay the door on by covering
the surface with cardboard, disposable tarp or paper
large enough to contain the entire door.
3. Wear leather gloves, long sleeves and safety glasses
to protect against injury from any broken glass.
4. Ensure that unit has completely cooled. Remove
fascia, then door.
5. Lay door on prepared surface with the front facing
down.
6. Use a Phillips screwdriver to remove the 16 screws
holding the four retaining strips in place and set
aside.
7. Carefully remove the retaining strips and set aside.
8. Carefully remove broken/defective glass and dispose
of pieces. Dust any particles of glass off the door
frame and dispose of the covering it was laid on.
Any particles of broken glass could scratch the
replacement piece if contact is made during the
replacement. Scratches in the glass may cause
breakage.
9. Place a clean covering on your work surface.
10. Position the door frame face down upon the clean
surface and place the new glass on the frame with
the thin side of gasketing down, facing the front.
11. Reinstall the retainer strips using the screws removed
earlier. Take care not to over tighten the screws.
12. Replace the glass but do not latch until Lighting
Instructions (page 34) have been completed.
13. Replace fascia.
GLASS & BLO
WER REPLA
CEMENT
GLASS CLEANING
WARNING!
DO NOT CLEAN GLASS WHEN HOT!
TURN UNIT OFF AND ALLOW TO COOL. DO NOT USE
ABRASIVE CLEANERS ON GLASS SURFACE!
1. Turn off pilot light.
2. Remove fascia.
3. Open door by releasing four spring latches, two on top
and two on bottom of glass.
4. Using glass cleaner, wipe with soft cloth or clean
paper towel until surface is dry.
5. Relight pilot.
6. Close door.
7. Replace Fascia.
8. Check main burner’s operation.
NOTE: If you observe a white film on the door glass, use
a hard water deposit glass cleaner or contact your
dealer. The use of a glass cleaner will reduce the
mineral deposits.
NOTE:. Do not use abrasive materials or chemical cleaners.
BLOWER REPLACEMENT
Part #842-3790
1. Disconnect power to unit at power supply (this may require
shutting off power at the circuit breaker box).
2. Remove fascia and door.
3. Remove control panel cover.
4. Disconnect white wire from white wire at junction box
in unit.
5. Disconnect black wire from snap disc.
NOTE: Removing the blower requires passing the blower unit
through a restricted area. Care must be taken to ensure
that your gas line is out of the way. Depending on your
gas line installation, it may be necessary to disconnect
your gas line on the valve side of shutoff within the unit
and move the flex line aside.
6. Reach in and use Phillips screwdrier to remove (2) screw
in fron tof blower. Slide blower and plate off.
7. Pull blower forward, towards the back of valve.
8. Slide blower all the way to your right.
9. Rotate left side of blower towards the front of unit.
10. Carefully maneuver blower out the front, over gas line
between control panel and door latch.
11. Pull old blower off of blower plate and replace with new
part. Take care to get blower and (4) rubber mounts
back into place.
12. Install new blower in reverse order.
NOTE: When installing new blower ensure that rubber
grommets on the end being inserted first are not
dislodged from the blower.
4 Retaining Strips
Glass
16 Screws
Gasketing
(Thick side up.)
Frame Bottom
Frame Top