Quadra-Fire QVI30 Installer's Manual

Manual is about: Quadra-Fire Village Collection QVI30, QVI35

Summary of QVI30

  • Page 1

    1 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 models/modèles : qvi35, qvi30 underwriters laboratories listed homologué underwriters laboratories guide d’installation installers guide warning: if the information in these instructions is not followed exactly, a fire or expl...

  • Page 2

    2 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 read and understand all instructions carefully before starting the installation. Failure to follow these installation instructions may result in a possible fire hazard and will void the warranty. Prior to the first firing of t...

  • Page 3

    3 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 ! Never obstruct the flow of combustion and ventilation air. Keep the front of the appliance clear of all obstacles and materials for servicing and proper operations. Due to the high temperature, the appliance should be locate...

  • Page 4: Table of Contents

    4 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 safety and warning information ............................... 2 service parts list ........................................................ 5 section 1: approvals and codes ............................. 10 approval listing an...

  • Page 5: Service Parts

    5 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 part number list on following pages. / la liste des numéros de pièce se trouve à la page suivante. 10 6 9 11 7 12 13 14 4 5 (ng, lp) exploded parts diagram (gn, pl) vue éclatée des pièces service parts qvi35, qvi30 beginning m...

  • Page 6

    6 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 (ng, lp) service parts list / liste des pièces de rechange item / piÈce description part number / n° de piÈce 1 on/off rheostate / sur/de rheostate 319-510a 2 on/off rocker switch / interrupteur à bascule marche/arrÊt 060-511 ...

  • Page 7

    7 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 (ng, lp) service parts list / liste des pièces de rechange item / piÈce description part number / n° de piÈce 1 on/off rheostate / sur/de rheostate 319-510a 2 on/off rocker switch / interrupteur à bascule marche/arrÊt 060-511 ...

  • Page 8: Service Parts

    8 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 (ng, lp) exploded parts diagram (gn, pl) vue éclatée des pièces service parts beginning manufacturing date: 4-02 ending manufacturing date: ______ standing pilot ignition valve assembly qvi30, qvi35 10 11 2 8 9 1 3 6 5 7 4 ite...

  • Page 9

    9 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 log set assembly item / piÈce part description part number / n° de piÈce qvi35 qvi30 1 log 1 / bûche 1 srv330-701 srv340-701 2 log 2 / bûche 2 srv330-702 srv340-702 3 log 3 / bûche 3 srv330-703 srv340-703 4 log 4 / bûche 4 srv...

  • Page 10: Homologations Et Codes

    10 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 1 approvals and codes approval listing and codes appliance certification the quadra-fire models discussed in this installers guide have been tested to certification standards and listed by the applicable laboratories. Certifi...

  • Page 11

    11 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 approvals and codes (continued) homologations et codes (suite) high altitude installations u.L. Listed gas appliances are tested and approved without requiring changes for elevations from 0 to 2,000 feet in the u. S. A. And i...

  • Page 12

    12 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 2 getting started introducing the quadra-fire gas appliances quadra-fire direct vent gas appliances are designed to op- erate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the...

  • Page 13

    13 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 ! Getting started (continued) venting and installation 1. Quadra-fire gas inserts are designed for recessed in- stallations into solid fuel masonry or factory built non combustible fireplaces that have been installed in ac- c...

  • Page 14

    14 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 ! ! Getting started (continued) comment débuter (suite) 7. To assure top performance, safety and efficiency, inserts must be installed with an approved flue liner as per can/ cga b-149 or national fuel code ansi z223 and thes...

  • Page 15

    15 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 getting started (continued) when planning a fireplace insert installation, it’s necessary to determine: • the vent system configuration to be used. • gas supply piping. • whether optional accessories—devices such as a wall sw...

  • Page 16

    16 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 getting started (continued) figure 2. Insert diagram figure 2. Schéma de la cassette : comment débuter (suite) top view (vue du dessus) c a b gas access / accÈs du conduit À gaz surround / entourage door / porte glass assembl...

  • Page 17

    17 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 3 installing the insert step 1 installing the vent system vent system installation precautions before starting installation of vent kits, the installer should read these instructions and the vent kit instructions to ensure th...

  • Page 18

    18 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 installing the insert (continued) note: the damper of the masonry chimney may need to be removed to allow installation of the flexible-vent pipe. Warning: the solid fuel fireplace has been converted for use with gas only and ...

  • Page 19

    19 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 installing the insert (continued) figure 3. Minimum height from roof to lowest discharge opening roof pitch h (min.) ft. Flat to 6/12 1.0 6/12 to 7/12 1.25 over 7/12 to 8/12 1.5 over 8/12 to 9/12 2.0 over 9/12 to 10/12 2.5 ov...

  • Page 20

    20 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 installing the insert (continued) warning: the exhaust pipe must only be connected to the exhaust starting collar of the unit and the center collar of the termination cap. The inlet air pipe must only be connected to the inle...

  • Page 21

    21 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 installing the insert (continued) figure 5 figure 6 installation de la cassette (suite) exhaust starting collar (collet de raccord du conduit d’Évacuation) inlet air starting collar (collet de raccord du conduit d’admission d...

  • Page 22

    22 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 ! ! Step 2 positioning, leveling, and securing insert installing the insert (continued) 1. Place the insert into position. 2. Level the insert from side to side and from front to back. • if necessary use the leveling bolts in...

  • Page 23

    23 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 ! Installing the insert (continued) step 4 the gas supply line note: have the gas supply line installed in accordance with local building codes by a qualified installer approved and/or licensed as required by the locality. (i...

  • Page 24

    24 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 pressure natural gas propane minimum 5.0 inches 11.0 inches inlet pressure w.C. W.C. Maximum inlet 14.0 inches 14.0 inches gas pressure w.C. W.C. Manifold 3.5 inches 10. 0 inches pressure w.C. W.C. A one-eighth (1/8) inch (3 ...

  • Page 25

    25 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 figure 9. Standing pilot ignition wiring diagram step 6 wiring the fireplace installing the insert (continued) note: electrical wiring must be installed by a licensed electrician. Caution: disconnect remote controls if you ar...

  • Page 26

    26 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 installing the insert (continued) ! Figure 10. Fan wiring diagram warning: do not connect 110-120 vac to the wall switch or the control valve will be destroyed. Caution: label all wires prior to disconnec- tion when servicing...

  • Page 27

    27 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 positioning the logs if the gas logs have been factory installed they should not need to be positioned. If the logs have been packaged separately, refer to the installation instructions that accompany the logs. Save the log i...

  • Page 28

    28 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 installing the insert (continued) 1. Place a single layer of dime sized pieces of ember mate- rial onto the top of the burner. Place the pieces next to and around the burner ports. 2. After the logs are installed, fill in any...

  • Page 29

    29 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 installing the insert (continued) step 8 installing the trim surrounds warning: when finishing the fireplace insert, never obstruct or modify the air inlet/outlet grilles on the insert in any manner. Combustible materials mus...

  • Page 30

    30 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 installing the insert (continued) figure 14 4. Slide the surround against the face of the unit, aligning the holes in upper and lower, right and left corners and secure the surround to the unit with the attachment screws. Not...

  • Page 31

    31 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 ! ! Installing the insert (continued) step 9 before lighting the appliance before lighting the appliance, do the following: review safety warnings and cautions • read the safety and warning information section at the beginnin...

  • Page 32

    32 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 Étape 10 allumage de l’appareil vous avez revisé toutes les consignes de sécurité, vous avez vérifié que l’appareil ne présentait aucune fuite de gaz, vous savez que le système d’évacuation est bien dégagé et vous avez vérifi...

  • Page 33

    33 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 when you light your fireplace, you may notice: • this gas appliance produces heat which does have an associated odor or smell. If you feel this odor is excessive it may require the initial 3-4 hour continuous burn on high fol...

  • Page 34

    34 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 maintaining and servicing your appliance 4 appliance maintenance although the frequency of servicing and maintenance will depend on use and the type of installation, you should have a qualified service technician perform an a...

  • Page 35

    35 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 checking vent system frequency: before initial use and at least annually thereafter, more frequently if possible. By: qualified service technician/home owner. Task: inspect the external vent cap on a regular basis to ensure t...

  • Page 36

    36 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 troubleshooting 5 with proper installation, operation, and maintenance your gas fireplace will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qualified service ...

  • Page 37

    37 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 5 si le montage, l’utilisation et l’entretien de la cheminée sont corrects, elle doit assurer à son propriétaire de nombreuses années de fonctionnement sans problème. Si toutefois un problème se présente, cette section permet...

  • Page 38

    38 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 symptom possible cause corrective action 3. (continued) f. High limit switch is defective or has reached its maximum temperature. Allow the unit to cool. If the burner remains lit after the fireplace warms up, the switch is g...

  • Page 39: Dépannage

    39 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 quadra-fire, a brand of hearth & home technologies 1445 north highway, colville, wa 99114 imprimé aux États-unis • copyright 2006 symptôme causes possibles réparation 3. (suite) f. Butée de température défectueuse ou ayant at...

  • Page 40: Lifetime Warranty

    40 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 lifetime warranty limited lifetime warranty the hearth & home technologies limited lifetime warranty guarantees that the following components will work as designed for the lifetime of the stove or hearth & home technologies w...

  • Page 41: Garantie

    41 quadra-fire village collection • qvi30, qvi35 • 340-901ef rev. B • 2/06 garantie limitÉe À vie la garantie à vie limitée hearth & home technologies garantit que les composants suivants fonctionneront tels que conçus pour la durée de vie du poêle sinon hearth & home technologies les réparera ou le...