- DL manuals
- Quadra-Fire
- Indoor Fireplace
- QVI30S
- Owner's Manual
Quadra-Fire QVI30S Owner's Manual - page 18
Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09
18
Figure 9.4 Fan/Rheostat Wire Diagram
NOTE: IF ANY OF THE ORIGINAL
WIRE AS SUPPLIED WITH THE
APPLIANCE MUST BE REPLACED,
IT MUST BE REPLACED WITH TYPE
105
0
C RATED WIRE.
JUNCTION BOX
VARIABLE SPEED CONTROL
TEMPERATURE
SENSOR SWITCH
WHT
GRN
BLK
BLK
110-120 VAC
BLOWER
BLOWER RECEPTACLE
BLK
BLK
BLK
BLK
WHT
GROUND
WHT
BLK
BLK
BLK
FAN
TEMPERATURE
SENSOR SWITCH
SPEED CONTROL
(RHEOSTAT)
JUNCTION
BOX
GROUND WIRE
(ATTACH TO ANY
METAL SURFACE)
BEND
UP TABS
Summary of QVI30S
Page 1
1 quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 model(s): qvi30s qvi35s • do not store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • what to do if you smell gas - do not try to light any appliance - do not touch any electrical switc...
Page 2: Congratulations
Quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 2 congratulations listing label information/location model name: ___________________________________________ date purchased/installed: __________________ serial number: __________________________________________ location on appliance: ____________...
Page 3
3 quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 table of contents 1 listing and code approvals a. Appliance certifi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 b. Btu specifi cations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 c. High altitude installa...
Page 4
Quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 4 note: to assure top performance, safety and effi ciency, inserts must be installed with an approved fl ue liner as per can/cga b-149 or national fuel gas code ansi z223 and these instructions. Note: this installation must conform with local code...
Page 5
5 quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 quadra-fire gas inserts are designed for recessed installa- tions into solid fuel masonry or factory built non-combustible fi replaces that have been installed in accordance with the national, provincial, state and local building codes. Prior to...
Page 6: Top View
Quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 6 top view a c b 3 3 fireplace size requirements figure 3.1 fireplace opening note: for actual appliance dimensions refer to section 15. Minimum appliance size location qvi35s qvi30s inches millimeters inches millimeters a front width 33-1/4 845 2...
Page 7
7 quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 b. Clearances figure 3.2 clearances to mantels or other combustibles above appliance fire risk. • locate and install appliance to all clearance specifi cations in manual. Fire risk. Odor risk. • clearance to combustible material under the insert...
Page 8
Quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 8 fire risk. Asphyxiation risk. • terminations must meet minimum clearances. • exhaust gases are hot. • nearby vents may draw fumes into house. A. Vent termination minimum clearances figure 4.1 specifi es minimum vent heights for various pitched r...
Page 9
9 quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 caution all vent specifi cations must be followed. • this product is tested and listed to these specifi cations. • appliance performance will suffer if specifi cations are not followed. Exhaust vent pipe termination cap adaptor insulation seal i...
Page 10
Quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 10 6 6 installation preparation fire risk. A hearth or hearth extension (if present) must comply with either of the following: • the solid fuel burning fi replace manufacturer’s specifi cation. • local building codes required by authority having j...
Page 11
11 quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 a. Venting components 7 7 installing vent pipe and appliance the vertical vent termination system installed on this model includes: • one length of 3-inch fl exible vent pipe for combustion air (included with vent kit). Pipe will be either a 4-...
Page 12
Quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 12 figure 7.2 cut and bend flashing as needed to fit chimney sealant adhesive • trim chimney top plate to minimize excess overhang or bend over fl ue tile (see figure 7.2). • place 3/8 inch bead of 300º f silicone on fl ue tile top. C. Placing, se...
Page 13
13 quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 d. Installing adaptor and termination cap for installation of termination cap see minimum vent heights for various pitched roofs (see figure 7.2) . To install adaptor see figure 7.3. Roof pitch h (min.) ft. Flat to 6/12....................1.0* ...
Page 14
Quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 14 • ensure that gas line does not come in contact with outer wrap of appliance. Follow local codes. • incoming gas line should be piped into the valve compartment and connected to the 1/2 inch connection on the manual shutoff valve. • check all f...
Page 15
15 quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 fire hazard. Do not change the valve settings. • this valve has been preset at the factory. • changing valve settings may result in fi re hazard or bodily injury. High altitude installations u.L. Listed gas appliances are tested and approved wi...
Page 16
Quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 16 a. Wiring the appliance 9 9 electrical information note: this appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with national electric code ansi/nfpa 70-latest edition or the can...
Page 17
17 quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 b. Junction box installation figure 9.2 junction box installation junction box sidewall junction box access screw provided optional accessories connecting the electrical junction box is required if using a blower or remote. • plug the cord into...
Page 18
Quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 18 figure 9.4 fan/rheostat wire diagram note: if any of the original wire as supplied with the appliance must be replaced, it must be replaced with type 105 0 c rated wire. Junction box variable speed control temperature sensor switch wht grn blk ...
Page 19
19 quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 a. Mantel projections figure 10.1 shows the minimum vertical and corresponding maximum horizontal dimensions of appliance mantels or other combustible projections above the top front edge of the appliance, not the surround. 10 10 finishing figu...
Page 20
Quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 20 figure 11.1 placement of embers 11 11 appliance setup a. Remove shipping materials remove shipping materials from inside or underneath the fi rebox. B. Clean the appliance clean/vacuum any sawdust that may have accumulated inside the fi rebox o...
Page 21: Refractory Placement
21 quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 step 3: install the left side refractory in the same manner (see figure 11.4). Step 2: while holding the back wall in place, install the right side refractory. Bend down the small tab located on the top front edge of the fi rebox (see figure 11...
Page 22
Quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 22 log set assembly: logs-qvi30 f. Positioning the logs caution: logs are fragile! Carefully remove the logs from the packaging. If the gas logs have been factory installed they should not need to be positioned. If the logs have been packaged sepa...
Page 23
23 quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 log #2 (srv340-702): position log #2 by locating its slot over the tab on the front left of the burner. The slot in the left end of the log slides into the vertical metal edge in front of the square cut out on the base pan. Log #3 (srv340-703):...
Page 24
Quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 24 log #5 (srv340-706): place log #5 across log #1 and log # 3. The notch in the bottom of the log sets on the carved out edge on top of log #3. The back of the log sits in the grooved out area in log #1. Log #6 (srv340-705): place log #6 across l...
Page 25
25 quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 log set assembly: logs-qvi35 caution: logs are fragile! Carefully remove the logs from the packaging. 1 1 2 2 3 3 6 6 5 5 4 4 1 1 pilot pilot tab tab tab tab burner burner basepan basepan log #1 (srv330-701): place log #1 in the back on the ins...
Page 26
Quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 26 3 3 3 3 4 4 log #3 (srv330-703): position log #3 by locating its slot over the tab on the right front of the burner. The right end of log #3 is pushed up against the step in the base pan. 4 4 log #4 (srv340-705): rest log #4 in the left smooth ...
Page 27
27 quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 figure 11.5 glass assembly g. Glass assembly h. Air shutter setting optimal fl ame appearance is dependent on the air shutter setting. Adjustments should be made by a qualified technician. Handle glass doors with care. • inspect the gasket to e...
Page 28
Quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 28 fire risk. Explosion risk. Gas may build up while lighting pilot. • remove glass assembly before lighting pilot. • replace glass assembly after lighting pilot. A. Before lighting appliance this appliance has a standing pilot ignition. Before op...
Page 29: Lighting
29 quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 b. Lighting appliance standing pilot ignition 1. Turn off all electric power to the appliance if service is to be performed. 2. Open control access panel. 3. Move switch to “off” position. 4. Push in gas control knob slightly and turn clock- wi...
Page 30
Quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 30 c. Check pilot flame appearance pilot fl ame must contact the thermocouple and thermopile for reliable appliance operation. • pilot fl ame should be as shown in figure 12.1. D. After appliance is lit initial break-in procedure when you light th...
Page 31
31 quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 e. Frequently asked questions fire risk. High temperatures. Keep combustible household items away from appliance. Do not obstruct combustion and ventilation air. • do not place combustible items on top of or in front of appliance. • keep furnit...
Page 32
Quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 32 a. Standing pilot ignition system 13 13 troubleshooting with proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a...
Page 33
33 quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 troubleshooting (continued) symptom possible cause corrective action 3. Continued c. Defective valve. Turn the valve knob to the on position. Place the on/off switch in the on position. Check the millivolt meter a the thermopile terminals. The ...
Page 34
Quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 34 14 14 maintaining and servicing appliance although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a qualifi ed service technician should perform an appliance checkup at the beginning of eac...
Page 35
35 quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 inspect maintenance tasks doors, surrounds and fronts 1. Assess condition of screen and replace as necessary. Recommend addition of screen if one is not present. 2. Inspect for scratches, dents or other damage and repair as necessary. 3. Verify...
Page 36
Quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 36 figure 15.1 appliance dimensions 15 15 reference materials a. Appliance dimension diagram dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to section 3. A c b electrical access gas ...
Page 37
37 quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 b. Vent kits components direct vent flex liner kits (see figure 15.2) link-dv30b: masonry 3 inch fl ex liner kit. Sections expand to 30 feet. Includes: two liners, termination cap, fl ashing, and link adapter. Link-dv4-30b: masonry 3 inch fl ex...
Page 38: Qvi30S
Quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 38 service parts diagram qvi30s beginning manufacturing date: aug. 2007 ending manufacturing date: ______ r c. Service parts part number list on following page. Log set assembly 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 20 19.
Page 39: Qvi30S
39 quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 service parts diagram qvi30s service parts r important: this is dated information. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered fro...
Page 40: Qvi35S
Quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 40 service parts diagram qvi35s beginning manufacturing date: aug. 2007 ending manufacturing date: ______ service parts r 7 8 9 10 11 12 13 14 15 16 17 18 19 part number list on following page. Log set assembly 1 2 3 4 5 6.
Page 41: Qvi35S
41 quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 service parts diagram qvi35s service parts r important: this is dated information. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered fro...
Page 42: Qvi30S, Qvi35S
Quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 42 important: this is dated information. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer. Stocked at depot item...
Page 43
43 quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 d. Limited lifetime warranty Î.
Page 44
Quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 44.
Page 45
45 quadra-fire • qvi30s, qvi35s • 340-901 rev. I • 6/09 e. Contact information - notes - ________________________________________________________________________________ ________________________________________________________________________________ _________________________________________________...